Reference Documentation

Parameter Summary

Parameter Label "over switch" "over climate" "over valve" "central configuration"
name Name X X X -
thermostat_type Thermostat type X X X -
temperature_sensor_entity_id Temperature sensor entity id X X (auto-regulation) X -
external_temperature_sensor_entity_id External temperature sensor entity id X X (auto-regulation) X X
cycle_min Cycle duration (minutes) X X X -
temp_min Minimum allowed temperature X X X X
temp_max Maximum allowed temperature X X X X
device_power Device power X X X -
use_central_mode Enable centralized control X X X -
use_window_feature With window detection X X X -
use_motion_feature With motion detection X X X -
use_power_feature With power management X X X -
use_presence_feature With presence detection X X X -
heater_entity1_id 1st heater X - - -
heater_entity2_id 2nd heater X - - -
heater_entity3_id 3rd heater X - - -
heater_entity4_id 4th heater X - - -
heater_keep_alive Switch refresh interval X - - -
proportional_function Algorithm X - - -
climate_entity1_id Underlying thermostat - X - -
climate_entity2_id 2nd underlying thermostat - X - -
climate_entity3_id 3rd underlying thermostat - X - -
climate_entity4_id 4th underlying thermostat - X - -
valve_entity1_id Underlying valve - - X -
valve_entity2_id 2nd underlying valve - - X -
valve_entity3_id 3rd underlying valve - - X -
valve_entity4_id 4th underlying valve - - X -
ac_mode Use of air conditioning (AC)? X X X -
tpi_coef_int Coefficient for internal temperature delta X - X X
tpi_coef_ext Coefficient for external temperature delta X - X X
frost_temp Frost preset temperature X X X X
window_sensor_entity_id Window sensor (entity id) X X X -
window_delay Delay before turn-off (seconds) X X X X
window_auto_open_threshold High drop threshold for automatic detection (°/min) X X X X
window_auto_close_threshold Low drop threshold for automatic closure detection (°/min) X X X X
window_auto_max_duration Maximum duration of automatic turn-off (minutes) X X X X
motion_sensor_entity_id Motion sensor entity id X X X -
motion_delay Delay before motion is considered (seconds) X X X -
motion_off_delay Delay before end of motion is considered (seconds) X X X X
motion_preset Preset to use if motion is detected X X X X
no_motion_preset Preset to use if no motion is detected X X X X
power_sensor_entity_id Total power sensor (entity id) X X X X
max_power_sensor_entity_id Max power sensor (entity id) X X X X
power_temp Temperature during load shedding X X X X
presence_sensor_entity_id Presence sensor entity id (true if someone is present) X X X -
minimal_activation_delay Minimum activation delay X - - X
minimal_deactivation_delay Minimum deactivation delay X - - X
safety_delay_min Maximum delay between two temperature measurements X - X X
safety_min_on_percent Minimum power percentage to enter security mode X - X X
auto_regulation_mode Auto-regulation mode - X - -
auto_regulation_dtemp Auto-regulation threshold - X - -
auto_regulation_period_min Minimum auto-regulation period - X - -
inverse_switch_command Inverse the switch command (for switches with pilot wire) X - - -
auto_fan_mode Automatic fan mode - X - -
auto_regulation_use_device_temp Use of internal temperature of the underlying device - X - -
use_central_boiler_feature Add central boiler control - - - X
central_boiler_activation_service Boiler activation service - - - X
central_boiler_deactivation_service Boiler deactivation service - - - X
used_by_controls_central_boiler Indicates if the VTherm controls the central boiler X X X -
use_auto_start_stop_feature Indicates if the auto start/stop feature is enabled - X - -
auto_start_stop_level The detection level for auto start/stop - X - -

Sensors

With the thermostat, sensors are available to visualize alerts and the internal state of the thermostat. These are available in the entities of the device associated with the thermostat:

image

In order, there are:

  1. the main climate entity for thermostat control,
  2. the entity allowing the auto-start/stop feature,
  3. the entity allowing VTherm to follow changes in the underlying device,
  4. the energy consumed by the thermostat (value that increments continuously),
  5. the time of receipt of the last external temperature,
  6. the time of receipt of the last internal temperature,
  7. the average power of the device during the cycle (for TPI only),
  8. the time spent in the off state during the cycle (TPI only),
  9. the time spent in the on state during the cycle (TPI only),
  10. the load shedding state,
  11. the power percentage during the cycle (TPI only),
  12. the presence state (if presence management is configured),
  13. the security state,
  14. the window state (if window management is configured),
  15. the motion state (if motion management is configured),
  16. the valve opening percentage (for over_valve type),

The presence of these entities depends on whether the associated feature is enabled.

To color the sensors, add these lines and customize them as needed in your configuration.yaml:

frontend:
  themes:
    versatile_thermostat_theme:
      state-binary_sensor-safety-on-color: "#FF0B0B"
      state-binary_sensor-power-on-color: "#FF0B0B"
      state-binary_sensor-window-on-color: "rgb(156, 39, 176)"
      state-binary_sensor-motion-on-color: "rgb(156, 39, 176)"
      state-binary_sensor-presence-on-color: "lightgreen"
      state-binary_sensor-running-on-color: "orange"

and choose the theme versatile_thermostat_theme in the panel configuration. You will get something like this:

image

Actions (Services)

This custom implementation offers specific actions (services) to facilitate integration with other Home Assistant components.

Force Presence/Occupation

This service allows you to force the presence state independently of the presence sensor. This can be useful if you want to manage presence via a service rather than a sensor. For example, you can use your alarm to force absence when it is turned on.

The code to call this service is as follows:

service: versatile_thermostat.set_presence
data:
    presence: "off"
target:
    entity_id: climate.my_thermostat

Modify the Preset Temperature

This service is useful if you want to dynamically change the preset temperature. Instead of switching presets, some use cases require modifying the temperature of the preset. This way, you can keep the scheduler unchanged to manage the preset while adjusting the preset temperature. If the modified preset is currently selected, the target temperature change is immediate and will be applied in the next calculation cycle.

You can modify one or both temperatures (when present or absent) of each preset.

Use the following code to set the preset temperature:

service: versatile_thermostat.set_preset_temperature
data:
    preset: boost
    temperature: 17.8
    temperature_away: 15
target:
    entity_id: climate.my_thermostat

Or, to change the preset for the Air Conditioning (AC) mode, add the _ac prefix to the preset name like this:

service: versatile_thermostat.set_preset_temperature
data:
    preset: boost_ac
    temperature: 25
    temperature_away: 30
target:
    entity_id: climate.my_thermostat

Tip Notes

  • After a restart, presets are reset to the configured temperature. If you want your change to be permanent, you need to modify the preset temperature in the integration configuration.

Modify Security Settings

This service allows you to dynamically modify the security settings described here Advanced Configuration. If the thermostat is in security mode, the new settings are applied immediately.

To change the security settings, use the following code:

service: versatile_thermostat.set_safety
data:
    min_on_percent: "0.5"
    default_on_percent: "0.1"
    delay_min: 60
target:
    entity_id: climate.my_thermostat

ByPass Window Check

This service allows you to enable or disable a bypass for the window check. It allows the thermostat to continue heating even if the window is detected as open. When set to true, changes to the window's status will no longer affect the thermostat. When set to false, the thermostat will be disabled if the window is still open.

To change the bypass setting, use the following code:

service: versatile_thermostat.set_window_bypass
data:
    bypass: true
target:
    entity_id: climate.my_thermostat

Events

The key events of the thermostat are notified via the message bus. The following events are notified:

  • versatile_thermostat_safety_event: the thermostat enters or exits the security preset
  • versatile_thermostat_power_event: the thermostat enters or exits the power preset
  • versatile_thermostat_temperature_event: one or both temperature measurements of the thermostat haven't been updated for more than `safety_delay_min`` minutes
  • versatile_thermostat_hvac_mode_event: the thermostat is turned on or off. This event is also broadcast at the thermostat's startup
  • versatile_thermostat_preset_event: a new preset is selected on the thermostat. This event is also broadcast at the thermostat's startup
  • versatile_thermostat_central_boiler_event: an event indicating a change in the boiler's state
  • versatile_thermostat_auto_start_stop_event: an event indicating a stop or restart made by the auto-start/stop function

If you've followed along, when a thermostat switches to security mode, 3 events are triggered:

  1. versatile_thermostat_temperature_event to indicate that a thermometer is no longer responding,
  2. versatile_thermostat_preset_event to indicate the switch to the security preset,
  3. versatile_thermostat_hvac_mode_event to indicate the potential shutdown of the thermostat

Each event carries the event's key values (temperatures, current preset, current power, ...) as well as the thermostat's states.

You can easily capture these events in an automation, for example, to notify users.

Custom attributes

To tune the algorithm, you have access to the entire context seen and calculated by the thermostat through dedicated attributes. You can see (and use) these attributes in the HA "Developer Tools / States" UI. Enter your thermostat and you will see something like this:

image

The custom attributes are as follows:

Attribute Meaning
hvac_modes The list of modes supported by the thermostat
temp_min The minimum temperature
temp_max The maximum temperature
target_temp_step. The target temperature step
preset_modes The visible presets for this thermostat. Hidden presets are not displayed here
current_temperature The current temperature as reported by the sensor
temperature The target temperature
hvac_action The action currently being performed by the heater. Can be idle, heating, cooling
preset_mode The currently selected preset. Can be one of 'preset_modes' or a hidden preset like power
hvac_mode The currently selected mode. Can be heat, cool, fan_only, off
friendly_name The thermostat name
supported_features A combination of all features supported by this thermostat. See the official climate integration documentation for more information
is_presence_configured Indicates if the presence detection function is configured
is_power_configured Indicates if the power shedding function is configured
is_motion_configured Indicates if the motion detection function is configured
is_window_configured Indicates if the window opening detection function by sensor is configured
is_window_auto_configured Indicates if the window opening detection function by temperature drop is configured
is_safety_configured Indicates if the temperature sensor loss detection function is configured
is_auto_start_stop_configured Indicates if the auto-start/stop function is configured (over_climate only)
is_over_switch Indicates if the VTherm is of type over_switch
is_over_valve Indicates if the VTherm is of type over_valve
is_over_climate Indicates if the VTherm is of type over_climate
is_over_climate_valve Indicates if the VTherm is of type over_climate_valve (over_climate with direct valve control)
SECTION specific_states ------
is_on true if the VTherm is on (hvac_mode different from Off)
last_central_mode The last central mode used (None if the VTherm is not centrally controlled)
last_update_datetime The date and time in ISO8866 format of this state
ext_current_temperature The current outdoor temperature
last_temperature_datetime The date and time in ISO8866 format of the last indoor temperature reception
last_ext_temperature_datetime The date and time in ISO8866 format of the last outdoor temperature reception
is_device_active true if the underlying is active
device_actives The list of underlying devices currently seen as active
nb_device_actives The number of underlying devices currently seen as active
ema_temp The current average temperature. Calculated as the exponential moving average of previous values. Used to calculate temperature_slope
temperature_slope The current temperature slope in °/hour
hvac_off_reason Indicates the reason for the VTherm shutdown (hvac_off). Can be Window, Auto-start/stop or Manual
total_energy An estimate of the total energy consumed by this VTherm
last_change_time_from_vtherm The date/time of the last change made by VTherm
messages A list of messages explaining the current state calculation. See state messages
is_sleeping Indicates the VTherm is in sleep mode (valid for VTherm of type over_climate with direct valve control)
is_recalculate_scheduled Indicates that the recalculation of the underlying state has been delayed by time filtering to limit the number of interactions with the controlled equipment
SECTION configuration ------
ac_mode true if the equipment supports Cooling mode in addition to Heating mode
type The VTherm type (over_switch, over_valve, over_climate, over_climate_valve)
is_controlled_by_central_mode True if the VTherm can be centrally controlled
target_temperature_step The target temperature step (same as target_temp_step)
minimal_activation_delay_sec The minimum activation delay in seconds (used with TPI only)
minimal_deactivation_delay_sec The minimum deactivation delay in seconds (used with TPI only)
timezone The timezone used for dates/times
temperature_unit The temperature unit used
is_used_by_central_boiler Indicates if the VTherm can control the central boiler
max_on_percent The maximum power percentage value (used with TPI only)
have_valve_regulation Indicates if the VTherm uses regulation by direct valve control (over_climate with valve control)
cycle_min The cycle duration in minutes
SECTION preset_temperatures ------
[eco/confort/boost]_temp The configured temperature for preset xxx
[eco/confort/boost]_away_temp The configured temperature for preset xxx when presence is disabled or not_home
SECTION current_state ------
hvac_mode The calculated current mode
target_temperature The calculated current temperature
preset The calculated current preset
SECTION requested_state ------
hvac_mode The mode requested by the user
target_temperature The temperature requested by the user
preset The preset requested by the user
SECTION presence_manager ------ only if is_presence_configured is true
presence_sensor_entity_id The entity used for presence detection
presence_state on if presence is detected. off if absence is detected
SECTION motion_manager ------ only if is_motion_configured is true
motion_sensor_entity_id The entity used for motion detection
motion_state on if motion is detected. off if no motion is detected
motion_delay_sec The delay in seconds for motion detection when the sensor changes from off to on
motion_off_delay_sec The delay in seconds for no motion detection when the sensor changes from on to off
motion_preset The preset to use if motion is detected
no_motion_preset The preset to use if no motion is detected
SECTION power_manager ------ only if is_power_configured is true
power_sensor_entity_id The entity providing the home power consumption
max_power_sensor_entity_id The entity providing the maximum authorized power before shedding
overpowering_state on if over-power detection is detected. off otherwise
device_power The power consumed by the underlying when active
power_temp The temperature to use when shedding is activated
current_power The current home power consumption as reported by sensor power_sensor_entity_id
current_max_power The maximum authorized power as reported by sensor max_power_sensor_entity_id
mean_cycle_power An estimate of the average power consumed by the equipment over a cycle
SECTION window_manager ------ only if is_window_configured or is_window_auto_configured is true
window_state on if window open detection by sensor is active. off otherwise
window_auto_state on if window open detection by automatic detection algorithm is active. off otherwise
window_action The action taken when window open detection is effective. Can be window_frost_temp, window_eco_temp, window_turn_off, window_fan_only
is_window_bypass true if window detection bypass is enabled
window_sensor_entity_id The window open detection sensor (if is_window_configured)
window_delay_sec The delay before detection when the sensor state changes from off to on
window_off_delay_sec The delay before detection ends when the sensor state changes from on to off
window_auto_open_threshold The auto-detection threshold in °/hour
window_auto_close_threshold The detection end threshold in °/hour
window_auto_max_duration The maximum auto-detection duration in minutes
SECTION safety_manager ------
safety_state The safety state. on or off
safety_delay_min The delay before activating safety mode when one of the 2 temperature sensors stops sending measurements
safety_min_on_percent Heating percentage below which the thermostat will not go into safety mode (for TPI only)
safety_default_on_percent Heating percentage used when the thermostat is in safety mode (for TPI only)
SECTION auto_start_stop_manager ------ only if is_auto_start_stop_configured
is_auto_stop_detected true if automatic stop is triggered
auto_start_stop_enable true if the auto-start/stop function is authorized
auto_start_stop_level The auto-start/stop level. Can be auto_start_stop_none, auto_start_stop_very_slow, auto_start_stop_slow, auto_start_stop_medium, auto_start_stop_fast
auto_start_stop_dtmin The dt parameter in minutes of the auto-start/stop algorithm
auto_start_stop_accumulated_error The accumulated_error value of the auto-start/stop algorithm
auto_start_stop_accumulated_error_threshold The accumulated_error threshold of the auto-start/stop algorithm
auto_start_stop_last_switch_date The date/time of the last switch made by the auto-start/stop algorithm
SECTION vtherm_over_switch ------ only if is_over_switch
is_inversed true if the command is inverted (pilot wire with diode)
keep_alive_sec The keep-alive delay or 0 if not configured
underlying_entities the list of entities controlling the underlyings
on_percent The on percentage calculated by the TPI algorithm
on_time_sec The On period in sec. Must be on_percent * cycle_min
off_time_sec The off period in sec. Must be (1 - on_percent) * cycle_min
function The algorithm used for cycle calculation
tpi_coef_int The coef_int of the TPI algorithm
tpi_coef_ext The coef_ext of the TPI algorithm
calculated_on_percent The raw on_percent calculated by the TPI algorithm
vswitch_on_commands The list of custom commands for turning on the underlying
vswitch_off_commands The list of custom commands for turning off the underlying
SECTION vtherm_over_climate ------ only if is_over_climate or is_over_climate_valve
start_hvac_action_date Date/time of the last turn-on (hvac_action)
underlying_entities the list of entities controlling the underlyings
is_regulated true if auto-regulation is configured
auto_fan_mode The auto-fan mode. Can be auto_fan_none, auto_fan_low, auto_fan_medium, auto_fan_high, auto_fan_turbo
current_auto_fan_mode The current auto-fan mode. Can be auto_fan_none, auto_fan_low, auto_fan_medium, auto_fan_high, auto_fan_turbo
auto_activated_fan_mode The activated auto-fan mode. Can be auto_fan_none, auto_fan_low, auto_fan_medium, auto_fan_high, auto_fan_turbo
auto_deactivated_fan_mode The deactivated auto-fan mode. Can be auto_fan_none, auto_fan_low, auto_fan_medium, auto_fan_high, auto_fan_turbo
follow_underlying_temp_change true if VTherm should follow changes made directly on the underlying
auto_regulation_use_device_temp true if VTherm should use the underlying temperature for regulation calculation (should not be used in normal cases)
SUB-SECTION regulation ------ only if is_regulated
regulated_target_temperature The target temperature calculated by auto-regulation
auto_regulation_mode The auto-regulation mode. Can be auto_regulation_none, auto_regulation_valve, auto_regulation_slow, auto_regulation_light, auto_regulation_medium, auto_regulation_strong, auto_regulation_expert
regulation_accumulated_error The regulation_accumulated_error value of the auto-regulation algorithm
SECTION vtherm_over_valve ------ only if is_over_valve
valve_open_percent The valve opening percentage
underlying_entities the list of entities controlling the underlyings
on_percent The on percentage calculated by the TPI algorithm
on_time_sec The On period in sec. Must be on_percent * cycle_min
off_time_sec The off period in sec. Must be (1 - on_percent) * cycle_min
function The algorithm used for cycle calculation
tpi_coef_int The coef_int of the TPI algorithm
tpi_coef_ext The coef_ext of the TPI algorithm
auto_regulation_dpercent The valve will not be controlled if the opening delta is less than this value
auto_regulation_period_min The time filtering parameter value in minutes. Corresponds to the minimum interval between 2 valve commands (excluding user changes).
last_calculation_timestamp The date/time of the last valve opening command
calculated_on_percent The raw on_percent calculated by the TPI algorithm
SECTION vtherm_over_climate_valve ------ only if is_over_climate_valve
have_valve_regulation Indicates if VTherm uses regulation by direct valve control (over_climate with valve control). Is always true in this case
SUB-SECTION valve_regulation ------ only if have_valve_regulation
underlyings_valve_regulation the list of entities controlling valve opening (opening degrees), valve closing (closing_degrees) and calibration (offset_calibration)
valve_open_percent The valve opening percentage after applying the minimum allowed (see min_opening_degrees)
on_percent The on percentage calculated by the TPI algorithm
power_percent The applied power percentage
function The algorithm used for cycle calculation
tpi_coef_int The coef_int of the TPI algorithm
tpi_coef_ext The coef_ext of the TPI algorithm
min_opening_degrees The list of minimum authorized openings (one value per underlying)
auto_regulation_dpercent The valve will not be controlled if the opening delta is less than this value
auto_regulation_period_min The time filtering parameter value in minutes. Corresponds to the minimum interval between 2 valve commands (excluding user changes).
last_calculation_timestamp The date/time of the last valve opening command

These attributes will be requested when seeking help.

State messages

The specific_states.messages custom attribute contains a list of message codes that explain the current state. Messages can be:

Code Meaning
overpowering_detected An overpowering situation is detected
safety_detected A temperature measurement fault is detected that triggered VTherm safety mode
target_temp_window_eco Window detection forced the target temperature to the Eco preset
target_temp_window_frost Window detection forced the target temperature to the Frost preset
target_temp_power Power shedding forced the target temperature with the value configured for shedding
target_temp_central_mode The target temperature was forced by central mode
target_temp_activity_detected The target temperature was forced by motion detection
target_temp_activity_not_detected The target temperature was forced by no motion detection
target_temp_absence_detected The target temperature was forced by absence detection

Note: these messages are available in the VTherm UI Card under the information icon.