custom_components/systemair/api.py

Lines changed: 3 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,5 @@
11
"""API Client for Systemair VSR ventilation units using Modbus TCP."""
2+
23
import asyncio
34
from typing import Any
45

@@ -56,9 +57,7 @@ async def test_connection(self) -> bool:
5657
try:
5758
await self._ensure_connected()
5859
test_register_1based = parameter_map["REG_TC_SP"].register
59-
await self._client.read_holding_registers(
60-
address=test_register_1based - 1, count=1, device_id=self.slave_id
61-
)
60+
await self._client.read_holding_registers(address=test_register_1based - 1, count=1, device_id=self.slave_id)
6261
except (ModbusException, ModbusConnectionError) as e:
6362
LOGGER.error("Failed to connect during test: %s", e)
6463
return False
@@ -72,9 +71,7 @@ async def write_register(self, address_1based: int, value: int) -> None:
7271
async with self._lock:
7372
try:
7473
await self._ensure_connected()
75-
result = await self._client.write_register(
76-
address=address_1based - 1, value=value, device_id=self.slave_id
77-
)
74+
result = await self._client.write_register(address=address_1based - 1, value=value, device_id=self.slave_id)
7875
self._raise_if_response_error(result, f"Error writing to register {address_1based}")
7976
LOGGER.debug(f"Successfully wrote {value} to register {address_1based}")
8077
except (ModbusException, ModbusConnectionError) as e:

custom_components/systemair/modbus.py

Lines changed: 3 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -486,8 +486,7 @@ class ModbusParameter:
486486
reg_type=RegisterType.Holding,
487487
short="REG_USERMODE_HMI_CHANGE_REQUEST",
488488
description=(
489-
"New desired user mode as requested by HMI\n1: Auto\n2: Manual\n3: Crowded\n4: Refresh\n"
490-
"5: Fireplace\n6: Away\n7: Holiday"
489+
"New desired user mode as requested by HMI\n1: Auto\n2: Manual\n3: Crowded\n4: Refresh\n5: Fireplace\n6: Away\n7: Holiday"
491490
),
492491
min_value=1,
493492
max_value=7,
@@ -561,8 +560,7 @@ class ModbusParameter:
561560
reg_type=RegisterType.Holding,
562561
short="REG_PRESSURE_GUARD_AIRFLOW_LEVEL_SAF",
563562
description=(
564-
"Fan speed level for configurable pressure guard function.\n0: Off\n1: Minimum\n2: Low\n3: Normal\n"
565-
"4: High\n5: Maximum"
563+
"Fan speed level for configurable pressure guard function.\n0: Off\n1: Minimum\n2: Low\n3: Normal\n4: High\n5: Maximum"
566564
),
567565
min_value=0,
568566
max_value=5,
@@ -573,8 +571,7 @@ class ModbusParameter:
573571
reg_type=RegisterType.Holding,
574572
short="REG_PRESSURE_GUARD_AIRFLOW_LEVEL_EAF",
575573
description=(
576-
"Fan speed level for configurable pressure guard function.\n0: Off\n1: Minimum\n2: Low\n"
577-
"3: Normal\n4: High\n5: Maximum"
574+
"Fan speed level for configurable pressure guard function.\n0: Off\n1: Minimum\n2: Low\n3: Normal\n4: High\n5: Maximum"
578575
),
579576
min_value=0,
580577
max_value=5,