doc/rados: format Q&A list in t-mon.rst
Format a Q&A list in doc/rados/troubleshooting/troubleshooting.rst, in the "Clock Skews" section. Signed-off-by: Zac Dover <[email protected]>
1 parent a4561f8 commit aadb87a

File tree

1 file changed

+7
-4
lines changed

1 file changed

+7
-4
lines changed

doc/rados/troubleshooting/troubleshooting-mon.rst

Lines changed: 7 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -377,12 +377,15 @@ following:
377377
* EndRun `https://endruntechnologies.com <https://endruntechnologies.com/products/ntp-time-servers>`_
378378
* Netburner `https://www.netburner.com <https://www.netburner.com/products/network-time-server/pk70-ex-ntp-network-time-server>`_
379379

380-
What's the maximum tolerated clock skew?
380+
Clock Skew Questions and Answers
381+
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
382+
383+
**What's the maximum tolerated clock skew?**
381384

382385
By default, monitors allow clocks to drift up to a maximum of 0.05 seconds
383386
(50 milliseconds).
384387

385-
Can I increase the maximum tolerated clock skew?
388+
**Can I increase the maximum tolerated clock skew?**
386389

387390
Yes, but we strongly recommend against doing so. The maximum tolerated clock
388391
skew is configurable via the ``mon-clock-drift-allowed`` option, but it is
@@ -393,7 +396,7 @@ Can I increase the maximum tolerated clock skew?
393396
unforeseen effects on the stability of the monitors and overall cluster
394397
health.
395398

396-
How do I know whether there is a clock skew?
399+
**How do I know whether there is a clock skew?**
397400

398401
The monitors will warn you via the cluster status ``HEALTH_WARN``. When clock
399402
skew is present, the ``ceph health detail`` and ``ceph status`` commands
@@ -410,7 +413,7 @@ How do I know whether there is a clock skew?
410413
the reported offsets of other monitors are relative to the lead monitor, not
411414
to any external reference source.
412415

413-
What should I do if there is a clock skew?
416+
**What should I do if there is a clock skew?**
414417

415418
Synchronize your clocks. Using an NTP client might help. However, if you
416419
are already using an NTP client and you still encounter clock skew problems,

0 commit comments