Skip to content

Lateral processes out of order #69

@analytophile

Description

@analytophile

Addressing a Problem?

currently, lateral processes are handled in a separate loop from vertical processes, so location of the process in the :HydrologicProcesses list does not indicate order of operations. It would be useful to handle both lateral and vertical processes in proper sequence to avoid some trickery to get flushing to work. This requires a bit of an invasive refactor of the content in Solvers.cpp that may have backward compatibility ramifications

Potential Solution

No response

Additional context

No response

Contribution

  • I would be willing/able to open a Pull Request to contribute this feature.