Notifications
You must be signed in to change notification settings - Fork 54
ReleaseNotes
Changes in ThermoRawFileParser 1.4.0 (June 10. 2022):
- Precursor intensity was added to mzML files
Precursor intensity is now included in mzML output, the output should be fairly similar to ProteoWizard. However, the intensity value should be used with caution, see Issue 125 and cited issues.
- Support for all possible MS levels
All MS levels are included in the output, previously only up to MS3; mapping precursor scans using new method Issue 126
-
-xswitch has reversed its meaning
When
-xis defined reference and exception data will be excluded from the output, by default they will be included. Similar to Proteowizard.
- Plain mzML (non-indexed) is forced when using
-sand mzML format
When using output to STDOUT and mzML format, the format will be always non-indexed Issue 118
- Updated ontology terms for ionization methods (HUPO PSI-MS version 4.1.79)
Added / updated ionization methods, Issue 128 Thank you, @abdelq
- Switch to include noise and baseline data (
-N)
With the new switch
-N|noiseDatanoise and baseline data can be included in mzML output Issue 130 Thank you, @GeorgWa
- Spectral points are sorted by mass
- Metadata, format, and logging switches recognize both numeric and string values of parameters
It is possible to use both text representation (case-insensitive) and numeric representation for switches, i.e.
-f mzmland-f 1are the same Issue 121
Changes in ThermoRawFileParser 1.3.4 (April 20. 2021):
- Disable peak picking for specified MS levels
- Rollback of ThermoRawFileParser CV term until downstream tools update their PSI-MS CV
Changes in ThermoRawFileParser 1.3.3 (April 01. 2021):
- Removed BOM prefix in indexed mzML output
- Addition of MS:1000576 (no compression) CV term when no compression is used
- Same metadata output for both TEXT and JSON formats
- FAIMS compensation voltage output
- Thermo libraries upgrade to 5.0.0.71
-
-s, --stdoutoption addition for writing to standard out (mostly for Windows)
Changes in ThermoRawFileParser 1.3.2 (Oct 02. 2020):
- Flag -x include reference and exception peaks
- SPS masses are included as precursors in mzML
- Ignore all not .raw files when processing folder
- Updates in instrument and detector mapping to PSI-MS CV terms
Changes in ThermoRawFileParser 1.3.1 (Sep 08. 2020):
- Select MS levels to be written to the file (
-L|--msLevelcommand line argument) - Write precursor scan number in the TITLE of MGF file (
-P|--mgfPrecursorcommand line argument) - Correct version of the assembly
- Correct typo in
-aflag description
Changes in ThermoRawFileParser 1.3.0 (Aug 26. 2020):
- Able to extract additional detector data - UV, PDA, pressure chromatograms, PDA spectra (new command line argument
-a|--allDetectors) - Fix instrument mapping and adding new instruments (Exploris series, ID-X etc)
- Update PSI-MS ontology version
- Fix empty output directory bug
Changes in ThermoRawFileParser 1.2.3 (May 4. 2020):
- Default centroiding of segmented scan data
- Thermo libraries upgrade
Changes in ThermoRawFileParser 1.2.2 (Mar 2. 2020):
- Minor change in biocontainer docker file
Changes in ThermoRawFileParser 1.2.1 (Feb 14. 2020):
- Bug fixes
- Additional XIC input validation
Changes in ThermoRawFileParser 1.2.0 (Feb 6. 2020):
- Addition xic and query subcommands (beta)
- Minor bug fixes
Changes in ThermoRawFileParser 1.1.11 (Sep 25. 2019):
- Addition of more Thermo instrument models
Changes in ThermoRawFileParser 1.1.10 (Aug 23. 2019):
- input directory argument addition
- silent logging mode
- metadata output file argument addition
- error handling improvements
Changes in ThermoRawFileParser 1.1.9 (Jul 2. 2019):
- no zlib compression flag addition for the binary data in the mzML output
Changes in ThermoRawFileParser 1.1.8 (Jun 18. 2019):
- addition of a progress indicator
- in MGF output: if no charge is found, no
CHARGEheader instead ofCHARGE=0+
Changes in ThermoRawFileParser 1.1.7 (Jun 4. 2019):
- reports the monoisotopic mass as precursor mass when available
- fixed MS3 precursor scan not found
- fixed wrong scan type annotation (centroid/profile) in mzML output
- log file appender is commented out
- addition of --version argument
- updated thermo library to version to 5.0.0.6
- added extra log statement with the number of scans being processed
- fixed max and min charge bug in json metadata output