Skip to content

Power state after power/AC loss doesn't work on the Protectli VP2440 #1813

@debugafterdark

Description

@debugafterdark

Component

Dasharo firmware

Device

Protectli VP2440

Dasharo version

Dasharo (coreboot+UEFI) v0.9.1-rc3

Dasharo Tools Suite version

No response

Test case ID

No response

Brief summary

There is a setting in the firmware configuration to control the power state of the device after an AC power loss.

That feature doesn't work for me, whatever option is chosen, the system always powers on after a power loss.

How reproducible

100%

How to reproduce

  1. Enter the firmware configuration screen and navigate to "Dasharo System Features" -> "Power Management Options"
  2. Set "Power state after system gets into when power/AC loss" to either "Powered Off" or "The state at the moment of power failure"
  3. Apply, let the OS boot and shut down cleanly
  4. Unplug the power cord and wait a few seconds
  5. Plug the power cord back in

Expected behavior

The device stays powered off.

Actual behavior

The device powers on.

Screenshots

No response

Additional context

No response

Solutions you've tried

No response

Metadata

Metadata

Assignees

No one assigned

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions