-- SLCD.VHD (a peripheral module for SCOMP)
-- 2014.11.18
--
-- Very simple LCD controller which interprets a SCOMP 16 word as part data
-- and part instruction. All meaningful control of the LCD is done in software.
--
-- See datasheets for the HD44780 or equivalent LCD controller.
LIBRARY IEEE;
USE IEEE.STD_LOGIC_1164.ALL;
ENTITY SLCD IS
PORT(
CLOCK_10KHZ : IN STD_LOGIC;
RESETN : IN STD_LOGIC;
CS : IN STD_LOGIC;
IO_DATA : IN STD_LOGIC_VECTOR(15 DOWNTO 0);
LCD_RS : OUT STD_LOGIC;
LCD_RW : OUT STD_LOGIC;
LCD_E : OUT STD_LOGIC;
LCD_D : OUT STD_LOGIC_VECTOR(7 DOWNTO 0)
);
END SLCD;
ARCHITECTURE a OF SLCD IS
-- Register to hold the last value sent to this LCD controller
SIGNAL data_in : STD_LOGIC_VECTOR(15 DOWNTO 0);
BEGIN
LCD_RW <= '0'; -- Always write to the LCD, never read
LCD_D <= data_in(7 DOWNTO 0); -- The low byte is interpreted as data
-- The highest bit is used to select the instruction or data register
WITH data_in(15) SELECT
LCD_RS <= '0' WHEN '1',
'1' WHEN OTHERS;
-- The second highest bit is interpreted as a finish transaction flag
WITH data_in(14) SELECT
LCD_E <= '0' WHEN '1',
'1' WHEN OTHERS;
-- Put IO_DATA into data_in when a new value has been sent.
-- Also, clear data_in when the DE2Bot is reset.
PROCESS (RESETN, CS) BEGIN
IF (RESETN = '0') THEN
data_in <= x"0000";
ELSIF (RISING_EDGE(CS)) THEN
data_in <= IO_DATA;
END IF;
END PROCESS;