File tree Expand file tree Collapse file tree 2 files changed +6
-6
lines changed
Expand file tree Collapse file tree 2 files changed +6
-6
lines changed Original file line number Diff line number Diff line change 9494 (users are encouraged to expand on that in group history/sample_preparation).
9595 </doc >
9696 </field >
97- <field name =" temperature_env" type =" NX_NUMBER " optional =" true" >
97+ <group name =" temperature_env" type =" NXenvironment " optional =" true" >
9898 <doc >
9999 The temperature set for the liquid jet or the injection assembly.
100100 Details may be added through instances of NXsensor/NXactuator the how this temperature
101101 value is obtained (whether a chiller unit was used, point of cooling, temperature reading
102102 etc.) and where this value would be expected (estimate for the jet assembly, the liquid
103103 prior to injection, or at the interaction point taking into account evaporative cooling etc.).
104104 </doc >
105- </field >
106- <field name =" gas_pressure_env" type =" NX_NUMBER " optional =" true" >
105+ </group >
106+ <group name =" gas_pressure_env" type =" NXenvironment " optional =" true" >
107107 <doc >
108108 Pressure in the interaction chamber under operation conditions and actuators/sensors
109109 controlling/measuring it.
110110 </doc >
111- </field >
111+ </group >
112112 <field name =" depends_on" recommended =" true" >
113113 <doc >
114114 Connects this liquidjet to its transformation chain.
Original file line number Diff line number Diff line change @@ -55,15 +55,15 @@ NXmpes_liquid(NXmpes):
5555 doc : |
5656 Material the microjet nozzle is made of
5757 (users are encouraged to expand on that in group history/sample_preparation).
58- temperature_env(NX_NUMBER ) :
58+ temperature_env(NXenvironment ) :
5959 exists : optional
6060 doc : |
6161 The temperature set for the liquid jet or the injection assembly.
6262 Details may be added through instances of NXsensor/NXactuator the how this temperature
6363 value is obtained (whether a chiller unit was used, point of cooling, temperature reading
6464 etc.) and where this value would be expected (estimate for the jet assembly, the liquid
6565 prior to injection, or at the interaction point taking into account evaporative cooling etc.).
66- gas_pressure_env(NX_NUMBER ) :
66+ gas_pressure_env(NXenvironment ) :
6767 exists : optional
6868 doc : |
6969 Pressure in the interaction chamber under operation conditions and actuators/sensors
You can’t perform that action at this time.
0 commit comments