- Plug in the Receiver module to the UART port on VESC master.
- Go to General App Settings and set the control method to: UART
- UART App Settings: 115200 baud
- Go to the Nunchuk App Settings screen.
- Set the highlighted Throttle settings fields appropriately.
IMPORTANT: The Nunchuk app settings default the Positive & Negative Ramping Time value to 0.9/0.3s which is 3x the normal default. Please ensure you update these to a more reasonable value (ie: 0.3/0.1)
- Deadband - I’ve been running 5%, the remote itself has virtually zero deadband but I would recommend keeping a minimum of 3% as I’ve not tested much below that. Throttle Curve can be adjusted on the next tab identically to how the PPM throttle curve is setup.