Notifications
You must be signed in to change notification settings - Fork 2
Expand file tree
/
Copy pathrefined_pipetting_protocol_test.py
More file actions
104 lines (93 loc) · 5.11 KB
/
refined_pipetting_protocol_test.py
File metadata and controls
104 lines (93 loc) · 5.11 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
from opentrons import protocol_api
# numpy may not be required, but can be used in code if specified
# - needs to be done for any other packages used directly in code
import numpy as np
#metadata
metadata = {
'apiLevel': '2.19',
'protocolName': 'Simple code test',
'description': 'use to evaluate refined pipetting and coding commands'
}
#Function that executes program
def run(protocol: protocol_api.ProtocolContext):
#Labware
#Use generic opentrons labware definitions if simulating
#setting up custom labware locations for simulations is not straightforward
#WHEN RUNNING IN THE LAB THESE MUST BE SUBSTITUTED FOR ACTUAL LABWARE BEING USED
source_plate = protocol.load_labware('nest_96_wellplate_100ul_pcr_full_skirt', 1)
destination_plate = protocol.load_labware('nest_96_wellplate_100ul_pcr_full_skirt', 2)
tiprack_1 = protocol.load_labware('opentrons_96_tiprack_300ul', 4)
#pipettes
pipette_right = protocol.load_instrument('p300_single_gen2', 'right', tip_racks=[tiprack_1])
#setting well clearances - acts as global parameter until redefined
#when setting need to consider volume and well characteristics
#important that liquid makes contact with well base, smaller volumes will require tighter clearance
#if liquid is already present in the well, will want to pipette into the liquid
#if tip touches base of well this will block aspirate and dispense functions
pipette_right.well_bottom_clearance.aspirate = 1 # tip is 1 mm above well bottom
pipette_right.well_bottom_clearance.dispense = 2
#setting pipette flow rates - acts as global parameter until redefined
#sets the actual rate in ul/s - this needs to be appropriate for a specific pipette
#Default flow rates - can increase these up to 2x or 3x (may have issues at higher speed)
#P20 Gen2 7.56 ul/s
#P300 Gen2 92.86 ul/s
#P1000 Gen2 274.7 ul/s
pipette_right.flow_rate.aspirate = 100
pipette_right.flow_rate.dispense = 100
pipette_right.flow_rate.blow_out = 200
#complex commands
pipette_right.transfer(
100,
source_plate['A1'].bottom(2),
destination_plate['B1'].bottom(5),
mix_before=(2,50),
touch_tip=True,
blow_out=True,
blowout_location="destination well",
new_tip='always',
)
# block commands
# Set of commands below does a single transfer followed by a mix
# Defining each step in turn enables much finer control of pipetting actions
# VALUES SHOWN BELOW HAVE NOT BEEN VALIDATED IN TESTING - that's your job!
# numbers below can be used with rate argument to set fraction of default flow rate
# you can globally change these, rather than adjusting each line of code separately
high=1.8
normal=1.0
slow=0.5
vslow=0.25
pipette_right.pick_up_tip()
pipette_right.aspirate(100, source_plate['A2'].bottom(1), rate=slow)
pipette_right.dispense(100, destination_plate['B2'].bottom(2), rate=vslow)
# mix function
# Block commands - can separately define rates and well heights for each step
# Don't have to aspirate and dispense from same height
# slower aspiration rates will give less chance of cavitation
# higher dispense rates gives better mixing
# slower final mix reduces chance of liquid remaining
# rate=() sets rate as a fraction of the value defined in the global 'instrument_context.flow_rate' above
pipette_right.aspirate(50, destination_plate['B2'].bottom(3), rate=slow)
pipette_right.dispense(50, destination_plate['B2'].bottom(1), rate=high)
pipette_right.aspirate(50, destination_plate['B2'].bottom(1), rate=slow)
pipette_right.dispense(50, destination_plate['B2'].bottom(3), rate=(normal*.75))
# short delay allows any excess liquid to settle in tip
protocol.delay(seconds=0.5)
# final slow aspirate and dispense to ensure good liquid recovery
# push_out in final dispense adds specified volume beyond the stop - different from blow out
pipette_right.aspirate(60, destination_plate['B2'].bottom(1), rate=slow)
pipette_right.dispense(60, destination_plate['B2'].bottom(3), rate=vslow, push_out=1)
# SLOWLY moving to a specific height in the well before blowout
pipette_right.move_to(destination_plate['B2'].top(-5), speed=5) # move to 2mm below the top of current well
# OR position can be specified in the .blow_out command, cannot include a rate OR speed argument.
# if no argument provided .blow_out() will blow out to current location
pipette_right.blow_out(destination_plate['B2'].top(-5))
# this version of touch tip sets the fraction of the tube radius for touching, so tip does not get bent
# v_offset sets height negative number is below rim
# speed = speed of tip movement so it does not crash around
# radius = sets the radius of the well diameter so the tip can be set to just touch
pipette_right.touch_tip(radius=0.9, v_offset=-5, speed=10)
pipette_right.drop_tip()
#print out commands so we can check the simulation
#ONLY REQUIRED IN SIMULATION, NOT WHEN RUNNING ROBOT
for line in protocol.commands():
print(line)