Skip to content

Frient EMIZB-151 reporting wrong energy value of 281474976710655 (0xFFFFFFFFFFFF)Β #30460

@Fabiancrg

Description

@Fabiancrg

What happened?

Regularly a wrong value for the energy is reported, it is 281474976710655 corresponding to 0xFFFFFFFFFFFF (48bit at 1)
This value is reported alone from endpoint 64 and it alternate with the other values from endpoint 2.

What did you expect to happen?

Only the vlues from endpoint 2 should be published

How to reproduce it (minimal and precise)

Issue occured after upgrade to Z2M version 2.7.2.
As far as I can see, this is due to a binding for seMetering on endpoint 64.
I deleted the binding on endpoint 64 and it works normally after that.

Zigbee2MQTT version

2.7.2

Adapter firmware version

20240710

Adapter

Sonoff ZDongle-P

Setup

Z2M runs in a LXC
Linux zigbee2mqtt 6.17.4-2-pve #1 SMP PREEMPT_DYNAMIC PMX 6.17.4-2 (2025-12-19T07:49Z) x86_64 GNU/Linux
Debian GNU/Linux 12

Device database.db entry

No response

Debug log

Jan 02 19:02:36 zigbee2mqtt pnpm[1312]: [2026-01-02 19:02:36] debug:         z2m: Received Zigbee message from 'Gaspard16_P1', type 'attributeReport', cluster 'seMetering', data '{"currentSummDelivered":281474976710655}' from endpoint 64 with groupID 0
Jan 02 19:02:37 zigbee2mqtt pnpm[1312]: [2026-01-02 19:02:37] info:         z2m:mqtt: MQTT publish: topic 'zigbee2mqtt/Gaspard16_P1', payload '{"current":4.63,"current_phase_b":0,"current_phase_c":5.58,"elapsed":1922,"energy":281474976710655,"energy_tier_1":3265.265,"energy_tier_2":2495.9410000000003,"last_seen":1767376956767,"linkquality":65,"power":900,"power_phase_b":0,"power_phase_c":300,"power_reactive":null,"power_reactive_phase_b":null,"power_reactive_phase_c":null,"produced_energy":4583.647,"produced_energy_tier_1":3318.541,"produced_energy_tier_2":1265.106,"update":{"installed_version":196871,"latest_version":196871,"state":"idle"},"voltage":232,"voltage_phase_b":0,"voltage_phase_c":226.1}'
Jan 02 19:02:39 zigbee2mqtt pnpm[1312]: [2026-01-02 19:02:39] debug:         z2m: Received Zigbee message from 'Gaspard16_P1', type 'attributeReport', cluster 'seMetering', data '{"currentSummDelivered":5761208,"currentSummReceived":4583647,"currentTier1SummDelivered":3265267,"currentTier1SummReceived":3318541,"currentTier2SummDelivered":2495941,"currentTier2SummReceived":1265106,"instantaneousDemand":1200}' from endpoint 2 with groupID 0
Jan 02 19:02:39 zigbee2mqtt pnpm[1312]: [2026-01-02 19:02:39] debug:         z2m: Received Zigbee message from 'Gaspard16_P1', type 'attributeReport', cluster 'haElectricalMeasurement', data '{"activePower":9,"activePowerPhB":0,"powerDivisor":10,"powerMultiplier":1,"reactivePower":null,"reactivePowerPhB":null,"rmsCurrent":464,"rmsCurrentPhB":0,"rmsCurrentPhC":541,"rmsVoltage":2315,"rmsVoltagePhB":0,"rmsVoltagePhC":2257,"totalActivePower":12,"totalReactivePower":null}' from endpoint 2 with groupID 0

Notes

No response

Metadata

Metadata

Assignees

No one assigned

    Labels

    problemSomething isn't working

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests