import logging
from control import data
from control.algorithm import common
from control.algorithm.chargemodes import CONSIDERED_CHARGE_MODES_MIN_CURRENT, CONSIDERED_CHARGE_MODES_PV_ONLY
from control.chargepoint.chargepoint_state import ChargepointState
from control.loadmanagement import Loadmanagement
from control.algorithm.filter_chargepoints import get_chargepoints_by_mode_and_counter
log = logging.getLogger(__name__)
class MinCurrent:
def __init__(self) -> None:
pass
def set_min_current(self) -> None:
for mode_tuple, counter in common.mode_and_counter_generator(CONSIDERED_CHARGE_MODES_MIN_CURRENT):
preferenced_chargepoints = get_chargepoints_by_mode_and_counter(mode_tuple, f"counter{counter.num}")
if preferenced_chargepoints:
log.info(f"Mode-Tuple {mode_tuple[0]} - {mode_tuple[1]} - {mode_tuple[2]}, Zähler {counter.num}")
common.update_raw_data(preferenced_chargepoints, diff_to_zero=True)
while len(preferenced_chargepoints):
cp = preferenced_chargepoints[0]
missing_currents, counts = common.get_min_current(cp)
if max(missing_currents) > 0:
available_currents, limit = Loadmanagement().get_available_currents(
missing_currents, counter, cp)
if limit.limiting_value is not None:
cp.data.control_parameter.limit = limit
available_for_cp = common.available_current_for_cp(
cp, counts, available_currents, missing_currents)
current = common.get_current_to_set(
cp.data.set.current, available_for_cp, cp.data.set.target_current)
if current < cp.data.control_parameter.min_current:
common.set_current_counterdiff(-(cp.data.set.current or 0), 0, cp)
if limit:
cp.set_state_and_log(
f"Ladung kann nicht gestartet werden{limit.message}")
else:
common.set_current_counterdiff(
cp.data.set.target_current,
cp.data.control_parameter.min_current,
cp)
else:
if mode_tuple in CONSIDERED_CHARGE_MODES_PV_ONLY:
try:
if (cp.data.control_parameter.state == ChargepointState.NO_CHARGING_ALLOWED or
cp.data.control_parameter.state == ChargepointState.SWITCH_ON_DELAY):
data.data.counter_all_data.get_evu_counter().switch_on_threshold_reached(cp)
except Exception:
log.exception(f"Fehler in der PV-gesteuerten Ladung bei {cp.num}")
cp.data.set.current = 0
preferenced_chargepoints.pop(0)