Tools Reference

Connection

connect

Connect to a Siglent oscilloscope over TCP. Returns device identification on success.

Parameter Type Required Default Description
host string No SIGLENT_IP env var IP address of the oscilloscope
port number No 5025 TCP port

disconnect

Disconnect from the oscilloscope. No parameters.

identify

Query the oscilloscope identification (*IDN?). Returns manufacturer, model, serial number, and firmware version. No parameters.


Channel

get_channel

Query the full configuration of an analog channel.

Parameter Type Required Description
channel C1 | C2 | C3 | C4 Yes Channel to query

Returns: volts/div, offset, coupling, bandwidth limit, trace on/off, probe attenuation, and unit.

configure_channel

Configure an analog channel. Only specified parameters are changed — omitted parameters are left untouched.

Parameter Type Required Description
channel C1 | C2 | C3 | C4 Yes Channel to configure
vdiv string No Volts per division with unit (e.g. 500mV, 1V, 2V). Range: 500uV–10V
offset string No Vertical offset with unit (e.g. 0V, -500mV, 1.5V)
coupling enum No Coupling mode (see table below)
bandwidth_limit boolean No Enable (true) or disable (false) 20 MHz bandwidth limit
trace boolean No Turn channel display on (true) or off (false)
probe number No Probe attenuation factor (1, 10, 100, 1000)

Coupling modes:

Value Description
A1M AC, 1 MOhm
A50 AC, 50 Ohm
D1M DC, 1 MOhm
D50 DC, 50 Ohm
GND Ground

Acquisition

configure_acquisition

Control the acquisition state and configure timebase/trigger settings. All parameters are optional — combine as needed in a single call.

Parameter Type Required Description
command enum No run (ARM), stop, single, auto
timebase string No Time per division with unit (e.g. 1US, 500NS, 10MS). Range: 1NS–100S
trigger_mode enum No AUTO, NORM, SINGLE, STOP
trigger_source enum No C1, C2, C3, C4, EX, EX5
trigger_level string No Trigger level voltage (e.g. 1.5V, 500mV)
trigger_slope enum No POS (rising), NEG (falling), WINDOW
trigger_delay string No Horizontal position (e.g. 0S, -4.8US)

get_acquisition_status

Query the current acquisition state. No parameters.

Returns: acquisition status, sample rate, timebase, trigger delay, trigger mode, trigger select, trigger level, and trigger slope.


Measurement

measure

Install a measurement on a channel and read the result.

Parameter Type Required Description
channel C1 | C2 | C3 | C4 Yes Channel to measure
parameter enum Yes Measurement type (see table below)

measure_statistics

Control measurement statistics — enable, disable, reset, or read statistical values (current, mean, min, max, std-dev, count).

Parameter Type Required Description
channel C1 | C2 | C3 | C4 Yes Channel to measure
parameter enum Yes Measurement type
action enum Yes on, off, reset, read

Measurement types:

Value Description
PKPK Peak-to-peak voltage
MAX Maximum voltage
MIN Minimum voltage
AMPL Amplitude
TOP Top voltage
BASE Base voltage
MEAN Mean voltage
CMEAN Cycle mean
RMS RMS voltage
CRMS Cycle RMS
OVSN Negative overshoot
OVSP Positive overshoot
FPRE Fall preshoot
RPRE Rise preshoot
FREQ Frequency
PER Period
PWID Positive pulse width
NWID Negative pulse width
RISE Rise time
FALL Fall time
WID Width
DUTY Positive duty cycle
NDUTY Negative duty cycle
ALL All measurements

Waveform

get_waveform

Download waveform data from a channel. Returns reconstructed voltage and time arrays.

Parameter Type Required Default Description
channel C1 | C2 | C3 | C4 Yes Channel to download from
max_points number No 1000 Maximum data points to return. Higher values give more detail but use more context.

Returns a JSON object with:

  • total_points / returned_points — raw count vs. downsampled count
  • sample_rate, timebase, volts_per_div, offset — acquisition parameters
  • time_range — start/end times
  • voltage_range — min/max voltages
  • data — array of {time, voltage} objects

screenshot

Capture the oscilloscope screen as a PNG image. Returns a base64-encoded image that Claude can display inline. No parameters.


SCPI Escape Hatch

For commands not covered by the built-in tools, send arbitrary SCPI directly.

scpi_query

Send a SCPI query and return the response.

Parameter Type Required Default Description
command string Yes SCPI query (e.g. *IDN?, C1:VDIV?, SARA?)
timeout_ms number No 2000 Response timeout in milliseconds

Note: CHDR is set to OFF on connect, so responses contain only values (no command headers).

scpi_command

Send a SCPI command with no response expected.

Parameter Type Required Description
command string Yes SCPI command (e.g. *RST, ARM, C1:VDIV 500mV)