articles/databox/data-box-overview.md

Lines changed: 3 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -6,7 +6,7 @@ author: stevenmatthew
66

77
ms.service: azure-databox
88
ms.topic: overview
9-
ms.date: 03/03/2025
9+
ms.date: 03/04/2025
1010
ms.author: shaas
1111
ms.custom: references_regions
1212
zone_pivot_groups: data-box-sku
@@ -108,6 +108,8 @@ The Data Box device has the following features in this release.
108108
| Data transfer rate | Approx. 7 GB/s using SMB Direct on RDMA (100-GbE) for large files. Both data ports can be used, though not required. Performance might differ depending on the source and size of your files.  |
109109
| Management | Local web UI - one-time initial setup and configuration <br> Azure portal - day-to-day device management |
110110

111+
[!INCLUDE [data-box-cable-adapter](../../includes/data-box-cable-adapter.md)]
112+
111113
## Next generation Data Box performance improvements
112114
The new version offers enhanced performance for data ingestion and upload, making it easier and faster for enterprise customers to migrate large-scale data to Azure without needing extensive on-premises network infrastructure. Key advancements include-
113115
- NVMe devices offer faster data transfer rates, with copy speeds up to 7GBps via SMB Direct on RDMA (100-GbE) for medium to large files, a 10x improvement in device transfers as compared to previous generation devices.

articles/databox/data-box-quickstart-export.md

Lines changed: 2 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -37,7 +37,8 @@ Before you begin:
3737
* You must have access to a flat surface where you can place the Data Box. If you want to place the device on a standard rack shelf, you need a 7U slot in your datacenter rack. You can place the device flat or upright in the rack.
3838
* You've procured the following cables to connect your Data Box to the host computer. These are recommended, however, the next generation devices will work with 10G cables too.
3939
* 2 x 10G-BaseT RJ-45 cables (CAT-5e or CAT6)
40-
* 2 x 100-GbE QSFP28 passive direct attached cable (use with DATA 1, DATA 2 network interfaces) 
40+
* 2 x 100-GbE QSFP28 passive direct attached cable (use with DATA 1, DATA 2 network interfaces)
41+
[!INCLUDE [data-box-cable-adapter](../../includes/data-box-cable-adapter.md)]
4142

4243
:::zone-end
4344
:::zone pivot="dbx"

articles/databox/data-box-quickstart-portal.md

Lines changed: 2 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -49,7 +49,8 @@ Before you begin:
4949
- You must have access to a flat surface where you can place the Data Box. If you want to place the device on a standard rack shelf, you need a 7U slot in your datacenter rack. You can place the device flat or upright in the rack.
5050
- You have the following cables to connect your Data Box to the host computer. These cables are recommended, however, the next generation devices will work with 10G cables too.
5151
- 2 x 10G-BaseT RJ-45 cables (CAT-5e or CAT6)
52-
- 2 x 100-GbE QSFP28 passive direct attached cable (use with DATA 1, DATA 2 network interfaces)
52+
- 2 x 100-GbE QSFP28 passive direct attached cable (use with DATA 1, DATA 2 network interfaces)
53+
[!INCLUDE [data-box-cable-adapter](../../includes/data-box-cable-adapter.md)]
5354
:::zone-end
5455

5556
:::zone pivot="dbx"

includes/data-box-cable-adapter.md

Lines changed: 12 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,12 @@
1+
---
2+
author: stevenmatthew
3+
ms.service: azure-databox
4+
ms.topic: include
5+
ms.date: 02/28/2025
6+
ms.author: shaas
7+
---
8+
9+
> [!IMPORTANT]
10+
> Data Box Next Gen 120TB and 525TB devices use QSFP28 cables. SFP+/SFP28 cables used with the original 80TB devices cannot be inserted directly into Data Box Next Gen devices without an appropriate adapter.
11+
>
12+
> :::image type="content" source="media/data-box-cable-adapter/qsfp-sml.png" alt-text="Image highlighting the differences between the SFP+, SFP28, and QSFP28 cables." lightbox="media/data-box-cable-adapter/qsfp-lrg.png":::