@@ -24,28 +24,26 @@ OT network sensors can detect the following protocols when identifying assets an
24
24
| ** Emerson** | DeltaV<br > DeltaV - Discovery<br > Emerson OpenBSI/BSAP<br > Ovation DCS ADMD<br >Ovation DCS DPUSTAT<br > Ovation DCS SSRPC |
25
25
| ** Emerson Fischer** | ROC |
26
26
| ** Eurocontrol** | ASTERIX |
27
- | ** GE** | Bentley Nevada (System 1 / BN3500)<br >ClassicSDI (MarkVle) <br > EGD<br > GSM (GE MarkVI and MarkVIe)<br >SDI (MarkVle) <br > SRTP (GE)<br > GE_CMP |
27
+ | ** GE** | Bentley Nevada (System 1 / BN3500)<br >ClassicSDI (MarkVle) <br > EGD<br > GSM (GE MarkVI and MarkVIe)<br > InterSite< br > SDI (MarkVle) <br > SRTP (GE)<br > GE_CMP |
28
28
| ** Generic Applications** | Active Directory<br > RDP<br > Teamviewer<br > VNC<br > |
29
29
| ** Honeywell** | ENAP<br > Experion DCS CDA<br > Experion DCS FDA<br > Honeywell EUCN <br > Honeywell Discovery |
30
30
| ** IEC** | Codesys V3<br >IEC 60870-5-7 (IEC 62351-3 + IEC 62351-5)<br > IEC 60870-5-101 (encapsulated serial)<br > IEC 60870-5-103 (encapsulated serial)<br > IEC 60870-5-104<br > IEC 60870-5-104 ASDU_APCI<br > IEC 60870 ICCP TASE.2<br > IEC 61850 GOOSE<br > IEC 61850 MMS<br > IEC 61850 SMV (SAMPLED-VALUES)<br > LonTalk (LonWorks) |
31
31
| ** IEEE** | LLC<br > STP<br > VLAN |
32
32
| ** IETF** | ARP<br > DHCP<br > DCE RPC<br > DNS<br > FTP (FTP_ADAT<br > FTP_DATA)<br > GSSAPI (RFC2743)<br > HTTP<br > ICMP<br > IPv4<br > IPv6<br > LLDP<br > MDNS<br > NBNS<br > NTLM (NTLMSSP Auth Protocol)<br > RPC<br > SMB / Browse / NBDGM<br > SMB / CIFS<br > SNMP<br > SPNEGO (RFC4178)<br > SSH<br > Syslog<br > TCP<br > Telnet<br > TFTP<br > TPKT<br > UDP |
33
- | ** InterSite** | <!-- tbd--> |
34
33
| ** ISO** | CLNP (ISO 8473)<br > COTP (ISO 8073)<br > ISO Industrial Protocol<br > MQTT (IEC 20922) |
35
34
| ** Medical** | ASTM<br > HL7 |
36
35
| ** Microsoft** | Horizon community dissectors<br > Horizon proprietary dissectors (developed by customers) |
37
36
| ** Mitsubishi** | Melsoft / Melsec (Mitsubishi Electric) |
38
37
| ** Omron** | FINS |
39
38
| ** OPC** | UA |
40
39
| ** Oracle** | TDS<br > TNS |
41
- | ** Profitnet I/O** | <!-- TBD--> |
42
40
| ** Rockwell Automation** | CSP2<br > ENIP<br > EtherNet/IP CIP (including Rockwell extension)<br > EtherNet/IP CIP FW version 27 and above |
43
41
| ** Samsung** | Samsung TV |
44
42
| ** Schneider Electric** | Modbus/TCP<br > Modbus TCP–Schneider Unity Extensions<br > OASYS (Schneider Electric Telvant)<br > Schneider TSAA |
45
43
| ** Schneider Electric / Invensys** | Foxboro Evo<br > Foxboro I/A<br > Trident<br > TriGP<br > TriStation |
46
44
| ** Schneider Electric / Modicon** | Modbus RTU |
47
45
| ** Schneider Electric / Wonderware** | Wonderware Suitelink |
48
- | ** Siemens** | CAMP<br > PCS7<br > PCS7 WinCC – Historian<br > Profinet DCP<br > Profinet Realtime<br > Siemens PHD<br > Siemens S7<br > Siemens S7 - Firmware and model extraction<br > • Siemens S7 – key state<br > Siemens S7-Plus<br > Siemens SICAM<br > Siemens WinCC |
46
+ | ** Siemens** | CAMP<br > PCS7<br > PCS7 WinCC – Historian<br > Profinet DCP<br > Profinet I/O< br > Profinet Realtime<br > Siemens PHD<br > Siemens S7<br > Siemens S7 - Firmware and model extraction<br > Siemens S7 – key state<br > Siemens S7-Plus<br > Siemens SICAM<br > Siemens WinCC |
49
47
| ** Toshiba** | Toshiba Computer Link |
50
48
| ** Yokogawa** | Centum ODEQ (Centum / ProSafe DCS)<br > HIS Equalize<br > FA-M3<br > Vnet/IP |
51
49
0 commit comments