Original file line numberDiff line numberDiff line change
@@ -31,9 +31,9 @@ The following actions are always recommended for ensuring host maintenance opera
3131
2. **Distributed Resource Scheduler (DRS) rules:** DRS VM-VM anti-affinity rules must be configured in a way to have at least (N+1) hosts in the cluster, where N is the number of VMs part of DRS rule.
3232
3. **Failures To Tolerate (FTT) violation:** To prevent data loss, change VMs configured with a vSAN storage policy for Failures to Tolerate (FTT) of 0 to a vSAN storage policy compliant with [Microsoft SLA](https://www.microsoft.com/licensing/docs/view/Service-Level-Agreements-SLA-for-Online-Services?lang=1) (FTT=1 for up to five hosts in a cluster and FTT=2 for six or more hosts in a cluster) and ensure host maintenance operations can carried out seamlessly.
3333
4. **Remove VM CD-ROM mounts:** VMs mounted with "Emulate mode" CD-ROMs block host maintenance. Ensure CD-ROMs are mounted in "Passthrough mode".
34-
5. **Serial/parallel port or external device:** If you are using an image file (ISO, FLP, etc), ensure that it is accessible from all ESXi hosts in the cluster. Store the files on a datastore that are shared between all ESXi Servers that participate in the vMotion of the virtual machine. Refer to [Broadcom KB article](https://knowledge.broadcom.com/external/article/324829/vmotion-fails-with-the-compatibility-err.html) for more information.
35-
6. **Orphaned VMs:** In the case of an orphaned virtual machine, the Virtual Machine (VM) needs to be either re-registered if possible (if it hasn't been deleted) or removed from inventory. Refer to [Broadcom KB article](https://knowledge.broadcom.com/external/article/312831/virtual-machines-appear-as-invalid-or-or.html) for more information.
36-
7. **SCSI shared controller:** When using SCSI bus sharing use with bus type as "Physical" for VMs. VMs connected to Virtual SCSCI controllers will be powered-off. Refer to [Broadcom KB article](https://knowledge.broadcom.com/external/article?legacyId=2147661) for more information.
34+
5. **Serial/parallel port or external device:** If you're using an image file (ISO, FLP, etc.), ensure that it's accessible from all ESXi hosts in the cluster. Store the files on a datastore that are shared between all ESXi Servers that participate in the vMotion of the virtual machine. For more information, see [Broadcom KB article](https://knowledge.broadcom.com/external/article/324829/vmotion-fails-with-the-compatibility-err.html).
35+
6. **Orphaned VMs:** In the case of an orphaned virtual machine, the Virtual Machine (VM) needs to be either re-registered if possible (if it hasn't been deleted) or removed from inventory. For more information, see [Broadcom KB article](https://knowledge.broadcom.com/external/article/312831/virtual-machines-appear-as-invalid-or-or.html).
36+
7. **SCSI shared controller:** When using SCSI bus sharing use with bus type as "Physical" for VMs. VMs connected to Virtual SCSCI controllers will be powered-off. For more information, see [Broadcom KB article](https://knowledge.broadcom.com/external/article?legacyId=2147661).
3737
8. **Third-party VMs & applications:** For third-party VMs & applications:
3838
1. Ensure that third-party solutions deployed on AVS are compliant and don't interfere with maintenance operations.
3939
2. Ensure that the VM isn’t installed with a VM-Host "Must run" DRS rule. Additionally, verify that these applications are compatible with upcoming versions of the VMware stack.
@@ -49,7 +49,7 @@ Azure VMware Solution monitors the following conditions on the host:
4949
- Hardware fan status
5050
- Network connectivity loss
5151
- Hardware system board status
52-
- Errors occurred on the disk(s) of a vSAN host
52+
- Errors occurred on one or more disks of a vSAN host
5353
- Hardware voltage
5454
- Hardware temperature status
5555
- Hardware power status
@@ -59,13 +59,13 @@ Azure VMware Solution monitors the following conditions on the host:
5959
## Alert Codes and Remediation Table
6060
| Error Code | Error Details | Recommended Action |
6161
|--------------------|---------------------------------|---------------------|
62-
| EPC_CDROM_EMULATEMODE | This error is encountered when CD-ROM on the Virtual Machine uses emulate mode, whose ISO image isn't accessible | Follow [this KB article](https://knowledge.broadcom.com/external/article?legacyId=79306) for the removal of any CDROM mounted on customer's workload Virtual Machines in emulate mode or detach ISO. It is recommended to use "Passthrough mode" for mounting any CD-ROM. |
62+
| EPC_CDROM_EMULATEMODE | This error is encountered when CD-ROM on the Virtual Machine uses emulate mode, whose ISO image isn't accessible | Follow [this KB article](https://knowledge.broadcom.com/external/article?legacyId=79306) for the removal of any CDROM mounted on customer's workload Virtual Machines in emulate mode or detach ISO. It's recommended to use "Passthrough mode" for mounting any CD-ROM. |
6363
| EPC_DRSOVERRIDERULE | This error is encountered when there's a Virtual Machine with DRS Override set to "Disabled" mode. | VM shouldn't block vMotion while putting host into maintenance. Set Partially Automated DRS rules for the VM. Refer to [this document](/azure/azure-vmware/create-placement-policy#enable-restrict-vm-movement-for-specific-vms) to know more about VM placement policies. |
6464
| EPC_SCSIDEVICE_SHARINGMODE | This error is encountered when a Virtual Machine is configured to use a device that prevents a maintenance operation: A device that is a SCSI controller which is engaged in bus-sharing | Follow [this KB article](https://knowledge.broadcom.com/external/article?legacyId=79910) for the removal of any SCSI controller engaged in bus-sharing attached to VMs |
6565
| EPC_DATASTORE_INACCESSIBLE | This error is encountered when any external Datastore attached to AVS Private Cloud becomes inaccessible | Follow [this article](/azure/azure-vmware/attach-azure-netapp-files-to-azure-vmware-solution-hosts?tabs=azure-portal#performance-best-practices) for the removal of any stale Datastore attached to cluster |
6666
| EPC_NWADAPTER_STALE | This error is encountered when connected Network interface on the Virtual Machine uses network adapter which becomes inaccessible | Follow [this KB article](https://knowledge.broadcom.com/external/article/318738/troubleshooting-the-migration-compatibil.html) for the removal of any stale N/W adapters attached to Virtual Machines |
67-
| EPC_SERIAL_PORT | This error is encountered when a Virtual Machine’s serial port is connected to a device that can't be accessed on the destination host. | If you're using an image file (ISO, FLP, and so on), ensure that it's accessible from all ESXi servers on the cluster. Store the files on a data store that is shared between all ESXi servers that will participate in vMotion of the virtual machine. Refer to [this KB article](https://knowledge.broadcom.com/external/article/324829/vmotion-fails-with-the-compatibility-err.html) from Broadcom for more information. |
68-
| EPC_HARDWARE_DEVICE | This error is encountered when a Virtual Machine’s parallel Port/USB Device is connected to a device cannot be accessed on the destination host. | If you're using an image file (ISO, FLP, and so on), ensure that it's accessible from all ESXi servers of the cluster. Store the files on a data store that is shared between all ESXi servers that will participate in the vMotion of the virtual machine. Refer to [this KB article](https://knowledge.broadcom.com/external/article/324829/vmotion-fails-with-the-compatibility-err.html) from Broadcom for more information. |
67+
| EPC_SERIAL_PORT | This error is encountered when a Virtual Machine’s serial port is connected to a device that can't be accessed on the destination host. | If you're using an image file (ISO, FLP, and so on), ensure that it's accessible from all ESXi servers on the cluster. Store the files on a data store that is shared between all ESXi servers that participate in vMotion of the virtual machine. Refer to [this KB article](https://knowledge.broadcom.com/external/article/324829/vmotion-fails-with-the-compatibility-err.html) from Broadcom for more information. |
68+
| EPC_HARDWARE_DEVICE | This error is encountered when a Virtual Machine’s parallel Port/USB Device is connected to a device can't be accessed on the destination host. | If you're using an image file (ISO, FLP, and so on), ensure that it's accessible from all ESXi servers of the cluster. Store the files on a data store that is shared between all ESXi servers that will participate in the vMotion of the virtual machine. Refer to [this KB article](https://knowledge.broadcom.com/external/article/324829/vmotion-fails-with-the-compatibility-err.html) from Broadcom for more information. |
6969
| EPC_INVALIDVM / EPC_ORPHANVM | This error is encountered when there's an orphaned or Invalid VM in the inventory | Ensure all your Virtual Machines are accessible to the vCenter. Refer to [this KB article](https://knowledge.broadcom.com/external/article/312831/virtual-machines-appear-as-invalid-or-or.html) for more information |
7070

7171