Skip to content

Commit 4911480

Browse files
authored
Merge pull request #222363 from yoninalmsft/appliance-docs-103128-9
Appliance SPAN/TAP throughput updates
2 parents faa7f85 + 2969297 commit 4911480

File tree

2 files changed

+27
-21
lines changed

2 files changed

+27
-21
lines changed

articles/defender-for-iot/organizations/ot-appliance-sizing.md

Lines changed: 18 additions & 13 deletions
Original file line numberDiff line numberDiff line change
@@ -7,37 +7,42 @@ ms.topic: conceptual
77

88
# Which appliances do I need?
99

10-
This article is designed to help you choose the right OT appliances for your sensors and on-premises management consoles. Use the tables below to understand which hardware profile best fits your organization's network monitoring needs. Performance values are upper thresholds and dependent on the analyzed traffic protocols, assuming that intermittent traffic profiles are typical of M2M systems.
10+
This article is designed to help you choose the right OT appliances for your sensors and on-premises management consoles. Use the tables below to understand which hardware profile best fits your organization's network monitoring needs.
1111

12-
Physical or virtual appliances can be used; results depend on hardware and resources available to the monitoring sensor.
12+
[Physical](ot-pre-configured-appliances.md) or [virtual](ot-virtual-appliances.md) appliances can be used; results depend on hardware and resources available to the monitoring sensor.
13+
14+
> [!NOTE]
15+
> The performance, capacity, and activity of an OT/IoT network may vary depending on its size, capacity, protocols distribution, and overall activity. For deployments, it is important to factor in raw network speed, the size of the network to monitor, and application configuration. The selection of processors, memory, and network cards is heavily influenced by these deployment configurations. The amount of space needed on your disk will differ depending on how long you store data, and the amount and type of data you store.
16+
>
17+
>*Performance values are presented as upper thresholds under the assumption of intermittent traffic profiles, such as those found in OT/IoT systems and machine-to-machine communication networks.*
1318
1419
## IT/OT mixed environments
1520

1621
Use the following hardware profiles for high bandwidth corporate IT/OT mixed networks:
1722

18-
|Hardware profile |Max throughput |Max monitored Assets |Deployment |
23+
|Hardware profile |SPAN/TAP throughput |Max monitored Assets |Deployment |
1924
|---------|---------|---------|---------|
20-
|C5600 | 3 Gbps | 12 K |Physical / Virtual |
25+
|C5600 | Up to 3 Gbps | 12 K |Physical / Virtual |
2126

2227
## Monitoring at the site level
2328

2429
Use the following hardware profiles for enterprise monitoring at the site level, typically collecting multiple traffic feeds:
2530

26-
|Hardware profile |Max throughput |Max monitored assets |Deployment |
31+
|Hardware profile |SPAN/TAP throughput |Max monitored assets |Deployment |
2732
|---------|---------|---------|---------|
28-
|E1800 |1 Gbps |10K |Physical / Virtual |
29-
|E1000 |1 Gbps |10K |Physical / Virtual |
30-
|E500 |1 Gbps |10K |Physical / Virtual |
33+
|E1800 |Up to 1 Gbps |10K |Physical / Virtual |
34+
|E1000 |Up to 1 Gbps |10K |Physical / Virtual |
35+
|E500 |Up to 1 Gbps |10K |Physical / Virtual |
3136

32-
## Production line monitoring
37+
## Production line monitoring (medium and small deployments)
3338

3439
Use the following hardware profiles for production line monitoring, typically in the production/mission-critical environments:
3540

36-
|Hardware profile |Max throughput |Max monitored assets |Deployment |
41+
|Hardware profile |SPAN/TAP throughput |Max monitored assets |Deployment |
3742
|---------|---------|---------|---------|
38-
|L500 | 200 Mbps | 1,000 |Physical / Virtual |
39-
|L100 | 60 Mbps | 800 | Physical / Virtual |
40-
|L60 | 10 Mbps | 100 |Physical / Virtual|
43+
|L500 | Up to 200 Mbps | 1,000 |Physical / Virtual |
44+
|L100 | Up to 60 Mbps | 800 | Physical / Virtual |
45+
|L60 | Up to 10 Mbps | 100 |Physical / Virtual|
4146

4247
## On-premises management console systems
4348

articles/defender-for-iot/organizations/ot-pre-configured-appliances.md

Lines changed: 9 additions & 8 deletions
Original file line numberDiff line numberDiff line change
@@ -30,25 +30,26 @@ Pre-configured physical appliances have been validated for Defender for IoT OT s
3030

3131
You can [order](mailto:[email protected][email protected]&subject=Information%20about%20Microsoft%20Defender%20for%20IoT%20pre-configured%20appliances&body=Dear%20Arrow%20Representative,%0D%0DOur%20organization%20is%20interested%20in%20receiving%20quotes%20for%20Microsoft%20Defender%20for%20IoT%20appliances%20as%20well%20as%20fulfillment%20options.%0D%0DThe%20purpose%20of%20this%20communication%20is%20to%20inform%20you%20of%20a%20project%20which%20involves%20[NUMBER]%20sites%20and%20[NUMBER]%20sensors%20for%20[ORGANIZATION%20NAME].%20Having%20reviewed%20potential%20appliances%20suitable%20for%20our%20project,%20we%20would%20like%20to%20obtain%20more%20information%20about:%20___________%0D%0D%0DI%20would%20appreciate%20being%20contacted%20by%20an%20Arrow%20representative%20to%20receive%20a%20quote%20for%20the%20items%20mentioned%20above.%0DI%20understand%20the%20quote%20and%20appliance%20delivery%20shall%20be%20in%20accordance%20with%20the%20relevant%20Arrow%20terms%20and%20conditions%20for%20Microsoft%20Defender%20for%20IoT%20pre-configured%20appliances.%0D%0D%0DBest%20Regards,%0D%0D%0D%0D%0D%0D//////////////////////////////%20%0D/////////%20Replace%20[NUMBER]%20with%20appropriate%20values%20related%20to%20your%20request.%0D/////////%20Replace%20[ORGANIZATION%20NAME]%20with%20the%20name%20of%20the%20organization%20you%20represent.%0D//////////////////////////////%0D%0D) any of the following pre-configured appliances for monitoring your OT networks:
3232

33-
|Hardware profile |Appliance |Performance / Monitoring |Physical specifications |
33+
|Hardware profile |Appliance |SPAN/TAP throughput |Physical specifications |
3434
|---------|---------|---------|---------|
35-
|**C5600** | [HPE ProLiant DL360](appliance-catalog/hpe-proliant-dl360.md) | **Max bandwidth**: 3Gbp/s <br>**Max devices**: 12,000 <br> 32 Cores/32G RAM/5.6TB | **Mounting**: 1U <br>**Ports**: 15x RJ45 or 8x SFP (OPT) |
36-
|**E1800** | [HPE ProLiant DL20 Gen10 Plus](appliance-catalog/hpe-proliant-dl20-plus-enterprise.md) (4SFF) <br><br> [Dell PowerEdge R350](appliance-catalog/dell-poweredge-r350-e1800.md) | **Max bandwidth**: 1 Gbp/s<br>**Max devices**: 10,000 <br> 8 Cores/32G RAM/1.8TB | **Mounting**: 1U <br>**Ports**: 8x RJ45 or 6x SFP (OPT) |
37-
|**E500** | [Dell Edge 5200](appliance-catalog/dell-edge-5200.md) <br> (Rugged MIL-STD-810G) | **Max bandwidth**: 1 Gbp/s<br>**Max devices**: 10,000 <br> 8 Cores/32G RAM/512GB | **Mounting**: Wall Mount<br>**Ports**: 3x RJ45 |
38-
|**L500** | [HPE ProLiant DL20 Gen10 Plus](appliance-catalog/hpe-proliant-dl20-plus-smb.md) <br> (NHP 2LFF) | **Max bandwidth**: 200Mbp/s<br>**Max devices**: 1,000 <br> 4 Cores/8G RAM/500GB | **Mounting**: 1U<br>**Ports**: 4x RJ45 |
39-
|**L100** | [YS-Techsystems YS-FIT2](appliance-catalog/ys-techsystems-ys-fit2.md) <br>(Rugged MIL-STD-810G) | **Max bandwidth**: 10Mbp/s <br>**Max devices**: 100 <br> 4 Cores/8G RAM/128GB | **Mounting**: DIN/VESA<br>**Ports**: 2x RJ45 |
35+
|**C5600** | [HPE ProLiant DL360](appliance-catalog/hpe-proliant-dl360.md) | **Max bandwidth**: Up to 3 Gbps <br>**Max devices**: 12K <br> 32 Cores/32G RAM/5.6TB | **Mounting**: 1U <br>**Ports**: 15x RJ45 or 8x SFP (OPT) |
36+
|**E1800** | [HPE ProLiant DL20 Gen10 Plus](appliance-catalog/hpe-proliant-dl20-plus-enterprise.md) (4SFF) <br><br> [Dell PowerEdge R350](appliance-catalog/dell-poweredge-r350-e1800.md) | **Max bandwidth**: Up to 1 Gbps<br>**Max devices**: 10K <br> 8 Cores/32G RAM/1.8TB | **Mounting**: 1U <br>**Ports**: 8x RJ45 or 6x SFP (OPT) |
37+
|**E500** | [Dell Edge 5200](appliance-catalog/dell-edge-5200.md) <br> (Rugged MIL-STD-810G) | **Max bandwidth**: Up to 1 Gbps<br>**Max devices**: 10K <br> 8 Cores/32G RAM/512GB | **Mounting**: Wall Mount<br>**Ports**: 3x RJ45 |
38+
|**L500** | [HPE ProLiant DL20 Gen10 Plus](appliance-catalog/hpe-proliant-dl20-plus-smb.md) <br> (NHP 2LFF) | **Max bandwidth**: Up to 200 Mbps<br>**Max devices**: 1,000 <br> 4 Cores/8G RAM/500GB | **Mounting**: 1U<br>**Ports**: 4x RJ45 |
39+
|**L100** | [YS-Techsystems YS-FIT2](appliance-catalog/ys-techsystems-ys-fit2.md) <br>(Rugged MIL-STD-810G) | **Max bandwidth**: Up to 10 Mbps <br>**Max devices**: 100 <br> 4 Cores/8G RAM/128GB | **Mounting**: DIN/VESA<br>**Ports**: 2x RJ45 |
4040

4141

4242
> [!NOTE]
43-
> Bandwidth performance may vary depending on protocol distribution.
43+
> The performance, capacity, and activity of an OT/IoT network may vary depending on its size, capacity, protocols distribution, and overall activity. For deployments, it is important to factor in raw network speed, the size of the network to monitor, and application configuration. The selection of processors, memory, and network cards is heavily influenced by these deployment configurations. The amount of space needed on your disk will differ depending on how long you store data, and the amount and type of data you store. <br><br>
44+
> *Performance values are presented as upper thresholds under the assumption of intermittent traffic profiles, such as those found in OT/IoT systems and machine-to-machine communication networks.*
4445
4546
## Appliances for on-premises management consoles
4647

4748
You can purchase any of the following appliances for your OT on-premises management consoles:
4849

4950
|Hardware profile |Appliance |Max sensors |Physical specifications |
5051
|---------|---------|---------|---------|
51-
|**E1800** | [HPE ProLiant DL20 Gen10 Plus](appliance-catalog/hpe-proliant-dl20-plus-enterprise.md) <br> (4SFF) | 300 | **Mounting**: 1U <br>**Ports**: 8x RJ45 or 6x SFP (OPT) |
52+
|**E1800** | [HPE ProLiant DL20 Gen10 Plus](appliance-catalog/hpe-proliant-dl20-plus-enterprise.md) (4SFF) <br><br> [Dell PowerEdge R350](appliance-catalog/dell-poweredge-r350-e1800.md) | 300 | **Mounting**: 1U <br>**Ports**: 8x RJ45 or 6x SFP (OPT) |
5253

5354
For information about previously supported legacy appliances, see the [appliance catalog](/azure/defender-for-iot/organizations/appliance-catalog/).
5455

0 commit comments

Comments
 (0)