Skip to content

Commit 7c89b6e

Browse files
committed
updates
1 parent 61f5143 commit 7c89b6e

File tree

2 files changed

+22
-23
lines changed

2 files changed

+22
-23
lines changed

articles/defender-for-iot/organizations/appliance-catalog/dell-poweredge-r350-e1800.md

Lines changed: 15 additions & 15 deletions
Original file line numberDiff line numberDiff line change
@@ -1,7 +1,7 @@
11
---
22
title: Dell PowerEdge R350 for OT monitoring - Microsoft Defender for IoT
33
description: Learn about the Dell PowerEdge R350 appliance's configuration when used for OT monitoring with Microsoft Defender for IoT in enterprise deployments.
4-
ms.date: 11/30/2022
4+
ms.date: 14/3/2024
55
ms.topic: reference
66
---
77

@@ -15,7 +15,7 @@ The Dell PowerEdge R350 is also available for the on-premises management console
1515
|**Hardware profile** | E1800|
1616
|**Performance** | Max bandwidth: 1 Gbps<br>Max devices: 10,000<br>Up to 8x RJ45 monitoring ports or 6x SFP (OPT) |
1717
|**Physical Specifications** | Mounting: 1U<br>Dimensions (H x W x D) 1.70 in x 17.09 in x 22.18 in<br>Dimensions (H x W x D) 4.28 cm x 43.4 cm x 56.3 cm|
18-
|**Status** | Supported, available as a pre-configured appliance|
18+
|**Status** | Supported, available as a preconfigured appliance|
1919

2020
The following image shows a view of the Dell PowerEdge R350 front panel:
2121

@@ -32,14 +32,14 @@ The following image shows a view of the Dell PowerEdge R350 back panel:
3232
|Chassis| 1U rack server|
3333
|Dimensions| (H x W x D) 1.70 in x 17.09 in x 22.18 in, 4.28 cm x 43.4 cm x 56.3 cm|
3434
|Weight| Max 28.96 lb/13.14 Kg|
35-
|Processor| Intel Xeon E-2334 3.4 GHz <br>8M Cache<br> 4C/8T, Turbo (65W), 3200 MT/s, XE Only|
35+
|Processor| Intel Xeon E-2334 3.4 GHz <br>8M Cache<br> 4C/8T, Turbo (65 W), 3200 MT/s, XE Only|
3636
|Memory|32 GB = 2x 16 GB 3200MT/s DDR4 ECC UDIMM|
37-
|Storage| 4x 1 TB Hard Drive SATA 6 Gbps 7.2K 512n 3.5in Hot-Plug with PERC H755 Controller Card - RAID 10|
37+
|Storage| 4x 1 TB Hard Drive SATA 6 Gbps 7.2 K 512n 3.5in Hot-Plug with PERC H755 Controller Card - RAID 10|
3838
|Network controller|On-board: Broadcom 5720 Dual Port 1 Gb On-Board LOM <br>On-board LOM: iDRAC9, Enterprise 15G<br>External: Broadcom 5719 Quad Port 1 GbE BASE-T Adapter, PCIe Low Profile|
3939
|Management|iDRAC9 Enterprise|
4040
|Device access| Two rear USB 3.0|
4141
|One front| USB 3.0|
42-
|Power| Dual, Hot-Plug, Redundant Power Supply (1+1), 600W|
42+
|Power| Dual, Hot-Plug, Redundant Power Supply (1+1), 600 W|
4343
|Rack support| ReadyRails Sliding Rails With Cable Management Arm|
4444

4545
## Dell PowerEdge R350 - Bill of Materials
@@ -48,13 +48,13 @@ The following image shows a view of the Dell PowerEdge R350 back panel:
4848
|----|---|----|
4949
|1| 210-BBTW | OEM R350XE Server |
5050
|1| 990-10090 | EX-Works |
51-
|1| 412-AAPW | Heatsink for 80W or less CPU |
51+
|1| 412-AAPW | Heatsink for 80 W or less CPU |
5252
|1| 370-AAIP | Performance Optimized |
5353
|1| 370-AGNY | 3200MT/s UDIMM |
5454
|2| 370-AGQU | 16 GB UDIMM, 3200MT/s, ECC |
5555
|1| 384-BBBH | Power Saving BIOS Settings |
5656
|1| 800-BBDM | UEFI BIOS Boot Mode with GPT Partition |
57-
|1| 450-AADY | C13 to C14, PDU Style, 10 AMP, 6.5 Feet (2m), Power Cord |
57+
|1| 450-AADY | C13 to C14, PDU Style, 10 AMP, 6.5 Feet (2 m), Power Cord |
5858
|1| 330-BBWS | Riser Config 0, 1 x8, 1 x16 slots |
5959
|1| 384-BCYX | OEM R350 Motherboard with Broadcom 5720 Dual Port 1 Gb On-Board LOM |
6060
|1| 385-BBQV | iDRAC9, Enterprise 15G |
@@ -88,7 +88,7 @@ The following image shows a view of the Dell PowerEdge R350 back panel:
8888
|2| 450-AMJH | Dual, Hot-Plug, Power Supply, 700W MM HLAC (200-220Vac) Titanium, Redundant (1+1), by LiteOn, NAF|
8989

9090
## Optional Storage Controllers
91-
Multi-disk RAID arrays combine multiple physical drives into one logical drive for increased redundancy and performance. The optional modules below have been tested in our lab for compatibility and sustained performance:
91+
Multi-disk RAID arrays combine multiple physical drives into one logical drive for increased redundancy and performance. The optional modules below are tested in our lab for compatibility and sustained performance:
9292

9393
|Quantity|PN|Description|
9494
|----|---|----|
@@ -100,10 +100,10 @@ Optional modules for additional monitoring ports can be installed:
100100
|Location |Type |Specifications |
101101
|----|---|----|
102102
| PCIe Expansion <br>Slot 1 or 2 | Quad Port Ethernet | 540-BBDV<br>Intel QP i350 4 x 1Gbe Copper, PCIe Low Profile |
103-
| PCIe Expansion <br>Slot 1 or 2 | Quad Port Ethernet | 540-BBDF<br>Broadcom 5719 Quad Port 1GbE BASE-T Adapter, PCIe Low Profile |
103+
| PCIe Expansion <br>Slot 1 or 2 | Quad Port Ethernet | 540-BBDF<br>Broadcom 5719 Quad Port 1 GbE BASE-T Adapter, PCIe Low Profile |
104104
| PCIe Expansion <br>Slot 1 or 2 | Dual Port Ethernet | 540-BCSE<br>Intel X710-T2L DP 2 x 10Gbe Copper, PCIe Low Profile |
105105
| PCIe Expansion <br>Slot 1 or 2 | Dual Port SFP+ | 540-BBML<br>Intel X710 DP 2 x 10Gbe SFP+, PCIe Low Profile |
106-
| PCIe Expansion <br>Slot 1 or 2 | Dual Port SFP+ | 540-BBVI<br>Broadcom 57412 Dual Port 10GbE SFP+ Adapter, PCIe Low Profile |
106+
| PCIe Expansion <br>Slot 1 or 2 | Dual Port SFP+ | 540-BBVI<br>Broadcom 57412 Dual Port 10 GbE SFP+ Adapter, PCIe Low Profile |
107107
| PCIe Expansion <br>Slot 1 or 2 | SFP+ Transceiver | 407-BCBN or 407-BBOU - SFP+ 10G SR |
108108
| PCIe Expansion <br>Slot 1 or 2 | SFP+ Transceiver | 407-BBOP - SFP+ 10G LR |
109109
| PCIe Expansion <br>Slot 1 or 2 | SFP+ Transceiver | 407-BBOS - SFP+ 1G COPPER |
@@ -121,18 +121,18 @@ Before installing the software on the Dell appliance, you need to adjust the app
121121
122122
### Prerequisites
123123

124-
To install the Dell PowerEdge R350 appliance, you'll need:
124+
To install the Dell PowerEdge R350 appliance, you need:
125125

126126
- An Enterprise license for Dell Remote Access Controller (iDrac)
127127

128128
- A BIOS configuration XML
129129

130-
### Setup the BIOS and RAID array
130+
### Set up the BIOS and RAID array
131131

132132
This procedure describes how to configure the BIOS configuration for an unconfigured sensor appliance.
133-
In the event that any of the steps below are missing in the BIOS, please make sure that the hardware matches the specifications above.
133+
If any of the steps below are missing in the BIOS, make sure that the hardware matches the specifications above.
134134

135-
Dell BIOS iDRAC is a system management software designed to give administrators control of Dell hardware remotely. It allows administrators to monitor system performance, configure settings, and troubleshoot hardware issues from a web browser. It can also be used to update system BIOS and firmware. The BIOS can be setup locally or remotely. To setup the BIOS remotely from a management computer, you need to define the iDRAC IP address and the management computer's IP address on the same subnet.
135+
Dell BIOS iDRAC is a system management software designed to give administrators control of Dell hardware remotely. It allows administrators to monitor system performance, configure settings, and troubleshoot hardware issues from a web browser. It can also be used to update system BIOS and firmware. The BIOS can be set up locally or remotely. To set up the BIOS remotely from a management computer, you need to define the iDRAC IP address and the management computer's IP address on the same subnet.
136136

137137
**To configure the iDRAC IP address**:
138138

@@ -219,7 +219,7 @@ The installation process takes about 20 minutes. After the installation, the sys
219219

220220
1. The media is mounted. Select **Close**.
221221

222-
1. Start the appliance. When you're using iDRAC, you can restart the servers by selecting the **Console Control** button. Then, on the **Keyboard Macros**, select the **Apply** button, which will start the Ctrl+Alt+Delete sequence.
222+
1. Start the appliance. When you're using iDRAC, you can restart the servers by selecting the **Console Control** button. Then, on the **Keyboard Macros**, select the **Apply** button, which starts the Ctrl+Alt+Delete sequence.
223223

224224
1. Continue by installing OT sensor or on-premises management software. For more information, see [Defender for IoT software installation](../how-to-install-software.md).
225225

articles/defender-for-iot/organizations/appliance-catalog/hpe-proliant-dl360.md

Lines changed: 7 additions & 8 deletions
Original file line numberDiff line numberDiff line change
@@ -1,7 +1,7 @@
11
---
22
title: HPE ProLiant DL360 OT monitoring - Microsoft Defender for IoT
33
description: Learn about the HPE ProLiant DL360 appliance when used for OT monitoring with Microsoft Defender for IoT.
4-
ms.date: 10/03/2022
4+
ms.date: 14/03/2024
55
ms.topic: reference
66
---
77

@@ -14,7 +14,7 @@ This article describes the **HPE ProLiant DL360** appliance for OT sensors, cust
1414
|**Hardware profile** | C5600 |
1515
|**Performance** | Max bandwidth: 3 Gbps <br> Max devices: 12,000 |
1616
|**Physical specifications** | Mounting: 1U<br>Ports: 15x RJ45 or 8x SFP (OPT)|
17-
|**Status** | Supported, available pre-configured|
17+
|**Status** | Supported, available preconfigured|
1818

1919
The following image describes the hardware elements on the HPE ProLiant DL360 back panel that are used by Defender for IoT:
2020

@@ -63,7 +63,7 @@ The following image describes the hardware elements on the HPE ProLiant DL360 ba
6363
|**874543-B21** | HPE 1U Gen10 SFF Easy Install Rail Kit |1|
6464

6565
## Optional Storage Controllers
66-
Multi-disk RAID arrays combine multiple physical drives into one logical drive for increased redundancy and performance. The optional modules below have been tested in our lab for compatibility and sustained performance:
66+
Multi-disk RAID arrays combine multiple physical drives into one logical drive for increased redundancy and performance. The optional modules below are tested in our lab for compatibility and sustained performance:
6767

6868
|Quantity|PN|Description|
6969
|----|---|----|
@@ -93,7 +93,7 @@ Optional modules for port expansion include:
9393

9494
This section describes how to install OT sensor software on the HPE ProLiant DL360 appliance and includes adjusting the appliance's BIOS configuration.
9595

96-
During this procedure, you'll configure the iLO port. We recommend that you also change the default password provided for the administrative user.
96+
During this procedure, you configure the iLO port. We recommend that you also change the default password provided for the administrative user.
9797

9898
> [!NOTE]
9999
> Installation procedures are only relevant if you need to re-install software on a pre-configured device, or if you buy your own hardware and configure the appliance yourself.
@@ -127,13 +127,12 @@ Use the following procedure to set up network options and update the default pas
127127

128128
1. Change the default password and select **F10: Save**.
129129

130-
### Setup the BIOS and RAID array
130+
### Set up the BIOS and RAID array
131131

132132
This procedure describes how to configure the BIOS configuration for an unconfigured sensor appliance.
133-
In the event that any of the steps below are missing in the BIOS, please make sure that the hardware matches the specifications above.
134-
135-
HPE BIOS iLO is a system management software designed to give administrators control of HPE hardware remotely. It allows administrators to monitor system performance, configure settings, and troubleshoot hardware issues from a web browser. It can also be used to update system BIOS and firmware. The BIOS can be setup locally or remotely. To setup the BIOS remotely from a management computer, you need to define the HPE IP address and the management computer's IP address on the same subnet.
133+
If any of the steps below are missing in the BIOS, make sure that the hardware matches the specifications above.
136134

135+
HPE BIOS iLO is a system management software designed to give administrators control of HPE hardware remotely. It allows administrators to monitor system performance, configure settings, and troubleshoot hardware issues from a web browser. It can also be used to update system BIOS and firmware. The BIOS can be set up locally or remotely. To set up the BIOS remotely from a management computer, you need to define the HPE IP address and the management computer's IP address on the same subnet.
137136

138137
**To configure the HPE BIOS**:
139138
> [!IMPORTANT]

0 commit comments

Comments
 (0)