Skip to content

Commit 86b5a8e

Browse files
committed
Acrolinux Related Updates
1 parent 81be99d commit 86b5a8e

File tree

1 file changed

+4
-4
lines changed

1 file changed

+4
-4
lines changed

articles/operator-nexus/troubleshoot-hardware-validation-failure.md

Lines changed: 4 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -215,7 +215,7 @@ Expanding `result_detail` for a given category shows detailed results.
215215

216216
### Network info category
217217

218-
* Network Interface Card (NIC) Check Failure
218+
* Network Interface Cards (NIC) Check Failure
219219
* Dell server NIC specs are defined in the SKU. A mismatched link status indicates loose or faulty cabling or crossed cables. A mismatched model indicates incorrect NIC card is inserted in to slot. Missing link/model fetched values indicate NICs that are failed, missing, or inserted in to incorrect slots.
220220

221221
```json
@@ -340,7 +340,7 @@ Expanding `result_detail` for a given category shows detailed results.
340340
}
341341
```
342342

343-
* To troubleshoot this problem, ensure that correct MAC address is defined in the cluster. If MAC is correct attempt a flea drain. If problem persists ensure that server is racked in the correct location, cabled accordingly, and that the correct IP is assigned.
343+
* To troubleshoot this problem, ensure that correct MAC address is defined in the cluster. If MAC is correct in the cluster object, attempt a flea drain. If problem persists ensure that server is racked in the correct location, cabled accordingly, and that the correct IP is assigned.
344344

345345
* Preboot execution environment (PXE) MAC Address Check Failure
346346
* The PXE MAC address is defined in the cluster for each BMM. A failed `PXE_MAC` check indicates a mismatch between the PXE MAC in the cluster and the actual MAC address retrieved from the machine.
@@ -354,7 +354,7 @@ Expanding `result_detail` for a given category shows detailed results.
354354
}
355355
```
356356

357-
* To troubleshoot this problem, ensure that correct MAC address is defined in the cluster. If MAC is correct attempt a flea drain. If problem persists ensure that server is racked in the correct location, cabled accordingly, and that the correct IP is assigned.
357+
* To troubleshoot this problem, ensure that correct MAC address is defined in the cluster. If MAC is correct in the cluster object, attempt a flea drain. If problem persists ensure that server is racked in the correct location, cabled accordingly, and that the correct IP is assigned.
358358

359359
### Health info category
360360

@@ -400,7 +400,7 @@ Expanding `result_detail` for a given category shows detailed results.
400400

401401
* To troubleshoot a server health failure engage vendor.
402402

403-
* Health Check Lifecycle (LC) Log Failures
403+
* Health Check LifeCycle (LC) Log Failures
404404
* Dell server health checks fail for recent Critical LC Log Alarms. The hardware validation plugin logs the alarm ID, name, and timestamp. Recent LC Log critical alarms indicate need for further investigation. The following example shows a failure for a critical backplane voltage alarm.