| 11 | +# Azure Operator Nexus Network Cloud Stock Keeping Units (SKUs) |
| 12 | + |
| 13 | +Operator Nexus Network Cloud SKUs for Azure Operator Nexus are meticulously designed to streamline the procurement and deployment processes, offering standardized bill of materials (BOM), topologies, wiring, and workflows. Microsoft crafts and prevalidates each SKU in collaboration with OEM vendors, ensuring seamless integration and optimal performance for operators. |
| 14 | + |
| 15 | +Operator Nexus Network Cloud SKUs offer a comprehensive range of options, allowing operators to tailor their deployments according to their specific requirements. With prevalidated configurations and standardized BOMs, the procurement and deployment processes are streamlined, ensuring efficiency and performance across the board. |
| 16 | + |
| 17 | +The following table outlines the various configurations of Operator Nexus Network Cloud SKUs, catering to different use-cases and functionalities required by operators. |
| 18 | + |
| 19 | +| Version | Use-Case | Network Cloud SKU ID | Description | BOM Components | |
| 20 | +|---------|-----------------------|-----------------------|------------------------------------------------------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------| |
| 21 | +| 1.7.3 | Multi Rack Near-Edge Aggregation (Agg) Rack | VNearEdge1_Aggregator_x70r3_9 | Aggregation Rack with Pure x70r3 | - Pair of Customer Edge Devices required for SKU.<br> - Two Management switch per rack deployed.<br> - Network packet broker device.<br> - Terminal Server.<br> - Pure storage array.<br> - Cable and optics. | |
| 22 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge1_Compute_DellR750_4C2M | Support up to eight Compute Racks where each rack can support four compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to four Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 23 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge1_Compute_DellR750_8C2M | Support up to eight Compute Racks where each rack can support eight compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to eight Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 24 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge1_Compute_DellR750_12C2M | Support up to eight Compute Racks where each rack can support 12 compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to 12 Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 25 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge1_Compute_DellR750_16C2M | Support up to eight Compute Racks where each rack can support 16 compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to 16 Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 26 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge2_Compute_DellR650_4C2M | 100G Fabric support up to eight Compute Racks where each rack can support four compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to four Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 27 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge2_Compute_DellR650_8C2M | 100G Fabric support up to eight Compute Racks where each rack can support eight compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to eight Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 28 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge2_Compute_DellR650_12C2M | 100G Fabric support up to eight Compute Racks where each rack can support 12 compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to 12 Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 29 | +| 1.7.3 | Multi Rack Near-Edge Compute | VNearEdge2_Compute_DellR650_16C2M | 100G Fabric support up to eight Compute Racks where each rack can support 16 compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to 16 Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 30 | +| 2.0.0 | Multi Rack Near-Edge Compute | VNearEdge4_Compute_DellR760_4C2M | Support up to eight Compute Racks where each rack can support four compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to four Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 31 | +| 2.0.0 | Multi Rack Near-Edge Compute | VNearEdge4_Compute_DellR760_8C2M | Support up to eight Compute Racks where each rack can support eight compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to eight Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 32 | +| 2.0.0 | Multi Rack Near-Edge Compute | VNearEdge4_Compute_DellR760_12C2M | Support up to eight Compute Racks where each rack can support 12 compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to 12 Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 33 | +| 2.0.0 | Multi Rack Near-Edge Compute | VNearEdge4_Compute_DellR760_16C2M | Support up to eight Compute Racks where each rack can support 16 compute servers. | - Pair of Top the rack switches per rack deployed. <br> - One Management switch per compute rack deployed.<br> - Two Management server per compute rack deployed. <br> - Up to 16 Compute servers per compute rack deployed. <br> - Cable and optics. | |
| 34 | +| 2.0.0 | Multi Rack Near-Edge Agg | VNearEdge4_Aggregator_x70r4 | Aggregation Rack with Pure x70r4. | - Pair of Customer Edge Devices required for SKU.<br> - Two Management switch per rack deployed.<br> - Network packet broker device.<br> - Terminal Server.<br> - Pure storage array.<br> - Cable and optics. | |
| 35 | +| 2.0.0 | Multi Rack Near-Edge Agg | VNearEdge4_Aggregator_x70r3 | Aggregation Rack with Pure x70r3. | - Pair of Customer Edge Devices required for SKU.<br> - Two Management switch per rack deployed.<br> - Network packet broker device.<br> - Terminal Server.<br> - Pure storage array.<br> - Cable and optics. | |
| 36 | +| 2.0.0 | Multi Rack Near-Edge Agg | VNearEdge4_Aggregator_x20r4 | Aggregation Rack with Pure x70r4. | - Pair of Customer Edge Devices required for SKU.<br> - Two Management switch per rack deployed.<br> - Network packet broker device.<br> - Terminal Server.<br> - Pure storage array.<br> - Cable and optics. | |
| 37 | +| 2.0.0 | Multi Rack Near-Edge Agg | VNearEdge4_Aggregator_x20r3 | Aggregation Rack with Pure x70r3. | - Pair of Customer Edge Devices required for SKU.<br> - Two Management switch per rack deployed.<br> - Network packet broker device.<br> - Terminal Server.<br> - Pure storage array.<br> - Cable and optics. | |
| 38 | + |
| 39 | +**Notes:** |
| 40 | +- Bill of materials (BOM) adheres to Nexus Network Cloud specifications. |
| 41 | +- All subscribed customers have the privilege to request BOM details. |