Skip to content

Commit 983ad07

Browse files
authored
Merge pull request #298954 from MSFT-FrankLpnsk/ERFlows2
ER Flows Update 2
2 parents 5f4596d + 92e5b23 commit 983ad07

File tree

1 file changed

+16
-19
lines changed

1 file changed

+16
-19
lines changed

includes/virtual-wan-expressroute-performance.md

Lines changed: 16 additions & 19 deletions
Original file line numberDiff line numberDiff line change
@@ -5,26 +5,23 @@
55
author: siddomala
66
ms.service: azure-virtual-wan
77
ms.topic: include
8-
ms.date: 03/04/2022
8+
ms.date: 04/28/2025
99
ms.author: siddomala
1010
ms.custom: include file
1111
---
12+
| Scale unit | Connections per second | Mega-bits per second | Packets per second | Total flows |
13+
|----------------|------------------------|----------------------|--------------------|-------------|
14+
| 1 | 14,000 | 2,000 | 200,000 | 200,000 |
15+
| 2 | 28,000 | 4,000 | 400,000 | 400,000 |
16+
| 3 | 42,000 | 6,000 | 600,000 | 600,000 |
17+
| 4 | 56,000 | 8,000 | 800,000 | 800,000 |
18+
| 5 | 70,000 | 10,000 | 1,000,000 | 1,000,000 |
19+
| 6 | 84,000 | 12,000 | 1,200,000 | 1,200,000 |
20+
| 7 | 98,000 | 14,000 | 1,400,000 | 1,400,000 |
21+
| 8 | 112,000 | 16,000 | 1,600,000 | 1,600,000 |
22+
| 9 | 126,000 | 18,000 | 1,800,000 | 1,800,000 |
23+
| 10 | 140,000 | 20,000 | 2,000,000 | 2,000,000 |
1224

13-
| **Scale unit** | **Connections per second** | **Mega-Bits per second** | **Packets per second** |
14-
|---|---|---|---|
15-
|1 scale unit <br> | 14,000 | 2,000 | 200,000
16-
|2 scale units <br> | 28,000 | 4,000 | 400,000
17-
|3 scale units <br> | 42,000 | 6,000 | 600,000
18-
|4 scale units <br> | 56,000 | 8,000 | 800,000
19-
|5 scale units <br> | 70,000 | 10,000 | 1,000,000
20-
|6 scale units <br> | 84,000 | 12,000 | 1,200,000
21-
|7 scale units <br> | 98,000 | 14,000 | 1,400,000
22-
|8 scale units <br> | 112,000 | 16,000 | 1,600,000
23-
|9 scale units <br> | 126,000 | 18,000 | 1,800,000
24-
|10 scale units <br> | 140,000 | 20,000 | 2,000,000
25-
26-
It is important to note the following:
27-
* Scale units 2-10, during maintenance operations, maintain aggregate throughput. However, scale unit 1, during a maintenance operation, may see a slight variation in throughput numbers.
28-
* Regardless of the number of scale units deployed, traffic may experience performance degradation if more than 1.5 Gbps is sent in a single TCP flow.
29-
30-
25+
It's important to consider the following points:
26+
* During maintenance operations, scale units 2 through 10 maintain their aggregate throughput. However, scale unit 1 can experience slight variations in throughput during such operations.
27+
* Regardless of the number of scale units deployed, if a single TCP flow exceeds 1.5 Gbps, traffic performance can degrade.

0 commit comments

Comments
 (0)