@@ -15,9 +15,9 @@ ms.date: 04/22/2019
1515

1616
# Quickstart: Explore the Azure Time Series Insights Preview demo environment
1717

18-
This quickstart gets you started with the Azure Time Series Insights Preview environment. By using the free demo, you tour key features that have been added to Time Series Insights Preview.
18+
This quickstart gets you started with the Azure Time Series Insights Preview environment. In the free demo, you tour key features that have been added to Time Series Insights Preview.
1919

20-
The Time Series Insights Preview demo environment contains a scenario company, Contoso, that operates two wind turbine farms. Each farm has 10 turbines. Each turbine has 20 sensors that report data every minute to Azure IoT Hub. The sensors gather information about weather conditions, blade pitch, and yaw position. Information about generator performance, gearbox behavior, and safety monitor also is recorded.
20+
The Time Series Insights Preview demo environment contains a scenario company, Contoso, that operates two wind turbine farms. Each farm has 10 turbines. Each turbine has 20 sensors that report data every minute to Azure IoT Hub. The sensors gather information about weather conditions, blade pitch, and yaw position. Information about generator performance, gearbox behavior, and safety monitors also is recorded.
2121

2222
In this quickstart, you learn how to use Time Series Insights to find actionable insights in Contoso data. You also conduct a short root cause analysis to better predict critical failures and to perform maintenance.
2323

@@ -36,35 +36,35 @@ The Time Series Insights Preview explorer demonstrates historical data and root
3636
1. In **Contoso Plant 1**, look at wind turbine **W7**.
3737

3838
1. Change the view range to **1/1/17 20:00 to 3/10/17 20:00 (UTC)**.
39-
1. To select the GeneratorSpeed sensor, select **Contoso Plant 1** > **W7** > **Generator System** > **GeneratorSpeed**. Then, review the values that are shown.
39+
1. To select a sensor, select **Contoso Plant 1** > **W7** > **Generator System** > **GeneratorSpeed**. Then, review the values that are shown.
4040

41-
[![W7 in Contoso Plant 1](media/v2-update-quickstart/quickstart-one.png)](media/v2-update-quickstart/quickstart-one.png#lightbox)
41+
[![W7 in Contoso Plant 1](media/v2-update-quickstart/quickstart-one.png)](media/v2-update-quickstart/quickstart-one.png#lightbox)
4242

4343
1. Recently, Contoso found a fire in wind turbine **W7**. Opinions vary about what caused the fire. In Time Series Insights, we can see that the fire alert sensor was activated during the fire.
4444

4545
1. Change the view range to **3/9/17 20:00 to 3/10/17 20:00 (UTC)**.
4646
1. Select **Safety System** > **FireAlert**.
4747

48-
[![Contoso found a fire in wind turbine W7](media/v2-update-quickstart/quickstart-two.png)](media/v2-update-quickstart/quickstart-two.png#lightbox)
48+
[![Contoso found a fire in wind turbine W7](media/v2-update-quickstart/quickstart-two.png)](media/v2-update-quickstart/quickstart-two.png#lightbox)
4949

5050
1. Review other events around the time of the fire to understand what occurred. Oil pressure and active warnings spiked just before the fire.
5151

5252
1. Select **Pitch System** > **HydraulicOilPressure**.
5353
1. Select **Pitch System** > **ActiveWarning**.
5454

55-
[![Review other events around the same time](media/v2-update-quickstart/quickstart-three.png)](media/v2-update-quickstart/quickstart-three.png#lightbox)
55+
[![Review other events around the same time](media/v2-update-quickstart/quickstart-three.png)](media/v2-update-quickstart/quickstart-three.png#lightbox)
5656

5757
1. The oil pressure and active warning sensors spiked right before the fire. Expand the displayed time series to see other signs that were evident leading up to the fire. Both sensors fluctuated consistently over time. The fluctuations indicate a persistent and worrisome pattern.
5858

5959
* Change the view range to **2/24/17 20:00 to 3/10/17 20:00 (UTC)**.
6060

61-
[![Oil pressure and active warning sensors also spiked](media/v2-update-quickstart/quickstart-four.png)](media/v2-update-quickstart/quickstart-four.png#lightbox)
61+
[![Oil pressure and active warning sensors also spiked](media/v2-update-quickstart/quickstart-four.png)](media/v2-update-quickstart/quickstart-four.png#lightbox)
6262

6363
1. Examining two years of historical data reveals another fire event that had the same sensor fluctuations.
6464

6565
* Change the view range to **1/1/16 to 12/31/17** (all data).
6666

67-
[![Look for historical patterns](media/v2-update-quickstart/quickstart-five.png)](media/v2-update-quickstart/quickstart-five.png#lightbox)
67+
[![Look for historical patterns](media/v2-update-quickstart/quickstart-five.png)](media/v2-update-quickstart/quickstart-five.png#lightbox)
6868

6969
Using Time Series Insights and our sensor telemetry, we've discovered a long-term and problematic trend hidden in the historical data. With these new insights, we can:
7070

@@ -80,36 +80,36 @@ Using Time Series Insights and our sensor telemetry, we've discovered a long-ter
8080
1. Change the view range to **6/1/17 20:00 to 7/1/17 20:00 (UTC)**.
8181
1. Select **Contoso Plant 1** > **W6** > **Safety System** > **VoltageActuatorSwitchWarning**.
8282

83-
[![Change the view range and select W6](media/v2-update-quickstart/quickstart-six.png)](media/v2-update-quickstart/quickstart-six.png#lightbox)
83+
[![Change the view range and select W6](media/v2-update-quickstart/quickstart-six.png)](media/v2-update-quickstart/quickstart-six.png#lightbox)
8484

8585
1. The warning indicates an issue with the voltage being output by the generator. The overall power output of the generator is operating within normal parameters in the current interval. By increasing our interval, another pattern emerges. A definite drop-off is evident.
8686

8787
1. Remove the **VoltageActuatorSwitchWarning** sensor.
8888
1. Select **Generator System** > **ActivePower**.
8989
1. Change the interval to **3d**.
9090

91-
[![Change the interval to 3d](media/v2-update-quickstart/quickstart-seven.png)](media/v2-update-quickstart/quickstart-seven.png#lightbox)
91+
[![Change the interval to 3d](media/v2-update-quickstart/quickstart-seven.png)](media/v2-update-quickstart/quickstart-seven.png#lightbox)
9292

9393
1. By expanding the time range, we can determine whether the issue has stopped or whether it continues.
9494

9595
* Extend the time span to 60 days.
9696

97-
[![Extend the time span to 60 days](media/v2-update-quickstart/quickstart-eight.png)](media/v2-update-quickstart/quickstart-eight.png#lightbox)
97+
[![Extend the time span to 60 days](media/v2-update-quickstart/quickstart-eight.png)](media/v2-update-quickstart/quickstart-eight.png#lightbox)
9898

9999
1. Other sensor data points can be added to provide greater context. The more sensors we view, the fuller our understanding of the problem is. Let’s drop a marker to see the actual values.
100100

101101
1. Select **Generator System**, and then select three sensors: **GridVoltagePhase1**, **GridVoltagePhase2**, and **GridVoltagePhase3**.
102102
1. Drop a marker on the last data point in the visible area.
103103

104-
[![Drop a marker](media/v2-update-quickstart/quickstart-nine.png)](media/v2-update-quickstart/quickstart-nine.png#lightbox)
104+
[![Drop a marker](media/v2-update-quickstart/quickstart-nine.png)](media/v2-update-quickstart/quickstart-nine.png#lightbox)
105105

106106
Two of the voltage sensors are operating comparably and within normal parameters. It looks like the **GridVoltagePhase3** sensor is the culprit.
107107

108108
1. With highly contextual data added, the phase 3 drop-off appears even more to be the problem. Now, we have a good lead on the cause of the warning. We’re ready to refer the issue to our maintenance team.
109109

110110
* Change the display to overlay all **Generator System** sensors on the same chart scale.
111111

112-
[![Change the display to include everything](media/v2-update-quickstart/quickstart-ten.png)](media/v2-update-quickstart/quickstart-ten.png#lightbox)
112+
[![Change the display to include everything](media/v2-update-quickstart/quickstart-ten.png)](media/v2-update-quickstart/quickstart-ten.png#lightbox)
113113

114114
## Next steps