Updating prerequisite for server BIOS
1 parent 4b31270 commit cce31d8

File tree

1 file changed

+62
-1
lines changed

1 file changed

+62
-1
lines changed

articles/operator-nexus/howto-platform-prerequisites.md

Lines changed: 62 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -599,7 +599,68 @@ An example design of three on-premises instances from the same NFC/CM pair, usin
599599
### Default setup for other devices installed
600600

601601
- All network fabric devices (except for the Terminal Server) are set to `ZTP` mode
602-
- Servers have default factory settings
602+
- Servers have default factory settings, inclusive of minimum BIOS settings.
603+
604+
#### Minimum BIOS and firmware versions for Nexus Cluster runtime
605+
606+
Ensure the following minimum BIOS and firmware versions are deployed based on your Nexus Cluster, based on the selected runtime version and BOM:
607+
608+
#### Nexus Cluster runtime version 4.4.x
609+
610+
##### BOM 1.7.3
611+
612+
| Component | Version |
613+
|-------------------------------------------------------------------------|---------------|
614+
| BIOS | 1.15.2 |
615+
| Storage Array Controller (PERC H755) | 52.26.0-5179 |
616+
| iDRAC | 7.10.90.00 |
617+
| Non-Expander Storage Backplane Passive SEP Firmware (15G Non-Expander) | 7.10 |
618+
| CPLD | 1.1.1 |
619+
| Mellanox ConnectX-6 DX Adapter | 22.41.1000 |
620+
| NVIDIA ConnectX-6 Lx 2x 25G SFP28 | 26.41.1000 |
621+
| Broadcom 5720 Quad Port 1GbE BASE-T Adapter | 22.91.5 |
622+
623+
##### BOM 2.0.0
624+
625+
| Component | Version |
626+
|-----------------------------------------------------|---------------|
627+
| BIOS | 2.4.4 |
628+
| Storage Array Controller (PERC H755) | 52.26.0-5179 |
629+
| iDRAC | 7.10.90.00 |
630+
| SAS Expander Backplane Firmware (R760) | 1.61 |
631+
| Non-Expander Storage Backplane Firmware (R660) | 7.10 |
632+
| CPLD | 1.2.6 |
633+
| Mellanox ConnectX-6 DX Adapter | 22.41.10.00 |
634+
| NVIDIA ConnectX-6 Lx 2x 25G SFP28 | 26.41.10.00 |
635+
| Broadcom 5720 Quad Port 1GbE BASE-T Adapter | 22.91.5 |
636+
637+
#### Nexus Cluster runtime version 4.1.x
638+
639+
##### BOM 1.7.3
640+
641+
| Component | Version |
642+
|-------------------------------------------------------------------------|---------------|
643+
| BIOS | 1.13.2 |
644+
| Storage Array Controller (PERC H755) | 52.26.0-5179 |
645+
| iDRAC | 7.10.30.00 |
646+
| Non-Expander Storage Backplane Passive SEP Firmware (15G Non-Expander) | 7.10 |
647+
| CPLD | 1.0.9 |
648+
| Mellanox ConnectX-6 DX Adapter | 22.35.10.12 |
649+
| Broadcom 5720 Quad Port 1GbE BASE-T Adapter | 22.61.8 |
650+
651+
##### BOM 2.0.0
652+
653+
| Component | Version |
654+
|-----------------------------------------------------|---------------|
655+
| BIOS | 2.2.7 |
656+
| Storage Array Controller (PERC H755) | 52.26.0-5179 |
657+
| iDRAC | 7.10.30.00 |
658+
| SAS Expander Backplane Firmware (R760) | 1.61 |
659+
| Non-Expander Storage Backplane Firmware (R660) | 7.10 |
660+
| CPLD | 1.2.1 |
661+
| Mellanox ConnectX-6 DX Adapter | 22.39.10.02 |
662+
| Broadcom 5720 Quad Port 1GbE BASE-T Adapter | 22.91.5 |
663+
603664

604665
## Firewall rules between Azure to Nexus Cluster.
605666

0 commit comments

Comments
 (0)