articles/healthcare-apis/iot/overview-of-fhir-destination-mapping.md

Lines changed: 34 additions & 35 deletions
Original file line numberDiff line numberDiff line change
@@ -1,11 +1,11 @@
11
---
22
title: Overview of the MedTech service FHIR destination mapping - Azure Health Data Services
3-
description: This article provides an overview of the MedTech service FHIR destination mapping.
3+
description: Learn about the MedTech service FHIR destination mapping.
44
author: msjasteppe
55
ms.service: healthcare-apis
66
ms.subservice: fhir
77
ms.topic: overview
8-
ms.date: 04/24/2023
8+
ms.date: 05/09/2023
99
ms.author: jasteppe
1010
---
1111

@@ -31,7 +31,7 @@ The FHIR destination mapping controls how the normalized data extracted from a d
3131

3232
These data types are all options the FHIR destination mapping configuration controls.
3333

34-
Once device data is transformed into a normalized data model, the normalized data is collected for transformation to a [FHIR Observation](https://www.hl7.org/fhir/observation.html). If the Observation type is [SampledData](https://www.hl7.org/fhir/datatypes.html#SampledData), the data is grouped according to device identifier, measurement type, and time period (time period can be either 1 hour or 24 hours). The output of this grouping is sent for conversion into a single [FHIR Observation](https://www.hl7.org/fhir/observation.html) that represents the time period for that data type. For other Observation types ([Quantity](https://www.hl7.org/fhir/datatypes.html#Quantity), [CodeableConcept](https://www.hl7.org/fhir/datatypes.html#CodeableConcept) and [string](https://www.hl7.org/fhir/datatypes.html#string)) data isn't grouped, but instead each measurement is transformed into a single Observation representing a point in time.
34+
Once device data is transformed into a normalized data model, the normalized data is collected for transformation to a [FHIR Observation](https://www.hl7.org/fhir/observation.html). If the Observation type is [SampledData](https://www.hl7.org/fhir/datatypes.html#SampledData), the data is grouped according to device identifier, measurement type, and time period (time period can be either 1 hour or 24 hours). The output of this grouping is sent for conversion into a single [FHIR Observation](https://www.hl7.org/fhir/observation.html) that represents the time period for that data type. For other Observation types ([Quantity](https://www.hl7.org/fhir/datatypes.html#Quantity), [CodeableConcept](https://www.hl7.org/fhir/datatypes.html#CodeableConcept) and [String](https://www.hl7.org/fhir/datatypes.html#string)) data isn't grouped, but instead each measurement is transformed into a single Observation representing a point in time.
3535

3636
> [!TIP]
3737
> For more information about how the MedTech service processes device message data into FHIR Observations for persistence on the FHIR service, see [Overview of the MedTech service device message processing stages](overview-of-device-message-processing-stages.md).
@@ -47,71 +47,71 @@ This diagram provides an illustration of what happens during the transformation
4747

4848
CollectionFhir is the root template type used by the MedTech service FHIR destination mapping. CollectionFhir is a list of all templates that are used during the transformation stage. You can define one or more templates within CollectionFhir, with each normalized message evaluated against all templates.
4949

50+
:::image type="content" source="media/overview-of-fhir-destination-mapping/fhir-destination-mapping-templates-diagram.png" alt-text="Diagram showing MedTech service FHIR destination mapping template and code architecture." lightbox="media/overview-of-fhir-destination-mapping/fhir-destination-mapping-templates-diagram.png":::
51+
5052
### CodeValueFhir
5153

52-
CodeValueFhir is currently the only template supported in FHIR destination mapping. It allows you to define codes, the effective period, and the value of the observation. Multiple value types are supported: [SampledData](https://www.hl7.org/fhir/datatypes.html#SampledData), [CodeableConcept](https://www.hl7.org/fhir/datatypes.html#CodeableConcept), [Quantity](https://www.hl7.org/fhir/datatypes.html#Quantity), and [string](https://www.hl7.org/fhir/datatypes.html#string). Along with these configurable values, the identifier for the Observation resource and linking to the proper Device and Patient resources are handled automatically.
54+
CodeValueFhir is currently the only template supported in the FHIR destination mapping. It allows you to define codes, the effective period, and the value of the observation. Multiple value types are supported: [SampledData](https://www.hl7.org/fhir/datatypes.html#SampledData), [CodeableConcept](https://www.hl7.org/fhir/datatypes.html#CodeableConcept), [Quantity](https://www.hl7.org/fhir/datatypes.html#Quantity), and [String](https://www.hl7.org/fhir/datatypes.html#string). Along with these configurable values, the identifier for the Observation resource and linking to the proper Device and Patient resources are handled automatically.
5355

5456
|Element|Description|Required|
5557
|:------|:----------|:-------|
56-
|**typeName**| The type of measurement this template should bind to. There should be at least one device mapping template that has this same `typeName`.|TBD|
57-
|**periodInterval**|The period of time the observation created should represent. Supported values are 0 (an instance), 60 (an hour), 1440 (a day).|TBD Note: `periodInterval` is required when the Observation type is "SampledData" and is ignored for any other Observation types.|
58-
|**category**|Any number of [CodeableConcepts](http://hl7.org/fhir/datatypes-definitions.html#codeableconcept) to classify the type of observation created.|TBD|
59-
|**codes**|One or more [Codings](http://hl7.org/fhir/datatypes-definitions.html#coding) to apply to the observation created.|TBD|
60-
|**codes[].code**|The code for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` property.|TBD|
61-
|**codes[].system**|The system for the [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding).|TBD|
62-
|**codes[].display**|The display for the [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding).|TBD|
63-
|**value**|The value to extract and represent in the observation. For more information, see [Value types](#value-types).|TBD|
64-
|**components**|*Optional:* One or more components to create on the observation.|TBD|
65-
|**components[].codes**|One or more [Codings](http://hl7.org/fhir/datatypes-definitions.html#coding) to apply to the component.|TBD|
66-
|**components[].value**|The value to extract and represent in the component. For more information, see [Value types](#value-types).|TBD|
67-
68-
:::image type="content" source="media/overview-of-fhir-destination-mapping/fhir-destination-mapping-templates-diagram.png" alt-text="Diagram showing MedTech service FHIR destination mapping template and code architecture." lightbox="media/overview-of-fhir-destination-mapping/fhir-destination-mapping-templates-diagram.png":::
69-
70-
### Value types
58+
|**typeName**| The type of measurement this template should bind to. Note: There should be at least one device mapping template that has this same `typeName`. The `typeName` element is used to link a FHIR destination mapping template to one or more device mapping templates. Device mapping templates with the same `typeName` element generate normalized data that is evaluated with a FHIR destination mapping template that has the same `typeName`.|True|
59+
|**periodInterval**|The period of time the observation created should represent. Supported values are 0 (an instance), 60 (an hour), 1440 (a day).|True when the Observation type is SampledData; Ignored for other Observation types.|
60+
|**category**|Any number of [CodeableConcepts](http://hl7.org/fhir/datatypes-definitions.html#codeableconcept) to classify the type of observation created.|False|
61+
|**codes**|One or more [Codings](http://hl7.org/fhir/datatypes-definitions.html#coding) to apply to the observation created.|True|
62+
|**codes[].code**|The code for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` element.|True|
63+
|**codes[].system**|The system for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` element.|False|
64+
|**codes[].display**|The display for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` element.|False|
65+
|**value**|The value to extract and represent in the observation. For more information on the elements that the `value` element contains, see [Value types](#value-types).|True when the `components` element isn't used (unless the Observation type is CodebleConcept, in which case this element isn't only 'not required' but also ignored).|
66+
|**components**|One or more components to create on the observation.|True when the `value` element isn't used instead.|
67+
|**components[].codes**|One or more [Codings](http://hl7.org/fhir/datatypes-definitions.html#coding) to apply to the component.|False|
68+
|**components[].value**|The value to extract and represent in the component. For more information on the elements that the `components[].value` element contains, see [Value types](#value-types).|True when the `components` element is used (unless the Observation type is CodebleConcept, in which case this element isn't only 'not required' but also ignored).|
69+
70+
#### Value types
7171

7272
All CodeValueFhir templates' `value` element contains these elements:
7373

7474
|Element|Description|Required|
7575
|:------|:----------|:-------|
76-
|**valueType**|Type of the value. This value would be "SampledData", "Quantity", "CodeableConcept", or "string" depending on the value type.|TBD|
77-
|**valueName**|Name of the value.|TBD|
76+
|**valueType**|Type of the value. This value would be "SampledData", "Quantity", "CodeableConcept", or "String" depending on the value type.|True|
77+
|**valueName**|Name of the value.|True unless `valueType` is CodeableConcept.|
7878

7979
These value types are supported in the MedTech service FHIR destination mapping:
8080

8181
#### SampledData
8282

83-
Represents the [SampledData](http://hl7.org/fhir/datatypes.html#SampledData) FHIR data type. Observation measurements are written to a value stream starting at a point in time and incrementing forward using the period defined. If no value is present, an `E` is written into the data stream. If the period is such that two or more values occupy the same position in the data stream, the latest value is used. The same logic is applied when an observation using the SampledData is updated. For a CodeValueFhir template with the SampleData value type, the template's `value` element contains the following elements:
83+
Represents the [SampledData](http://hl7.org/fhir/datatypes.html#SampledData) FHIR data type. Observation measurements are written to a value stream starting at a point in time and incrementing forward using the period defined. If no value is present, an `E` is written into the data stream. If the period is such that two or more values occupy the same position in the data stream, the latest value is used. The same logic is applied when an observation using the SampledData is updated. For a CodeValueFhir template with the SampledData value type, the template's `value` element contains the following elements:
8484

8585
|Element|Description|Required|
8686
|:------|:----------|:-------|
87-
|**defaultPeriod**|The default period in milliseconds to use.|TBD|
88-
|**unit**|The unit to set on the origin of the SampledData. |TBD|
87+
|**defaultPeriod**|The default period in milliseconds to use.|True|
88+
|**unit**|The unit to set on the origin of the SampledData.|True|
8989

9090
#### Quantity
9191

9292
Represents the [Quantity](http://hl7.org/fhir/datatypes.html#Quantity) FHIR data type. This type creates a single, point in time, Observation. If a new value arrives that contains the same device identifier, measurement type, and timestamp, the previous Observation is updated to the new value. For a CodeValueFhir template with the Quantity value type, the template's `value` element contains the following elements:
9393

9494
|Element|Description|Required|
9595
|:------|:----------|:-------|
96-
|**unit**|Unit representation.|TBD|
97-
|**code**|Coded form of the unit.|TBD|
98-
|**system**|System that defines the coded unit form.|TBD|
96+
|**unit**|Unit representation.|False|
97+
|**code**|Coded form of the unit.|False|
98+
|**system**|System that defines the coded unit form.|False|
9999

100100
#### CodeableConcept
101101

102102
Represents the [CodeableConcept](http://hl7.org/fhir/datatypes.html#CodeableConcept) FHIR data type. The value in the normalized data model isn't used, and instead when this type of data is received, an Observation is created with a specific code representing that an observation was recorded at a specific point in time. For a CodeValueFhir template with the CodeableConcept value type, the template's `value` element contains the following elements:
103103

104104
|Element|Description|Required|
105105
|:------|:----------|:-------|
106-
|**text**|Plain text representation.|TBD|
107-
|**codes**|One or more [Codings](http://hl7.org/fhir/datatypes-definitions.html#coding) to apply to the observation created.|TBD|
108-
|**codes[].code**|The code for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` property.|TBD|
109-
|**codes[].system**|The system for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` property.|TBD|
110-
|**codes[].display**|The display for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` property.|TBD|
106+
|**text**|Plain text representation.|False|
107+
|**codes**|One or more [Codings](http://hl7.org/fhir/datatypes-definitions.html#coding) to apply to the observation created.|True|
108+
|**codes[].code**|The code for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` element.|True|
109+
|**codes[].system**|The system for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` element.|False|
110+
|**codes[].display**|The display for a [Coding](http://hl7.org/fhir/datatypes-definitions.html#coding) in the `codes` element.|False|
111111

112112
#### String
113113

114-
Represents the [string](https://www.hl7.org/fhir/datatypes.html#string) FHIR data type. This type creates a single, point in time, Observation. If new a value arrives that contains the same device identifier, measurement type, and timestamp, the previous Observation is updated to the new value. No other elements are defined.
114+
Represents the [String](https://www.hl7.org/fhir/datatypes.html#string) FHIR data type. This type creates a single, point in time, Observation. If a new value arrives that contains the same device identifier, measurement type, and timestamp, the previous Observation is updated to the new value. No other elements are defined.
115115

116116
### Example
117117

@@ -167,7 +167,6 @@ We're using this FHIR destination mapping for the transformation stage:
167167
}
168168
]
169169
}
170-
171170
```
172171

173172
The resulting FHIR Observation will look like this after the transformation stage:
@@ -244,7 +243,7 @@ To learn how to use CalculatedContent with the MedTech service device mapping, s
244243
To learn how to use IotJsonPathContent with the MedTech service device mapping, see
245244

246245
> [!div class="nextstepaction"]
247-
> [How to use IotJsonPathContent with the MedTech service device mapping](how-to-use-iotjsonpathcontenttemplate-mappings.md)
246+
> [How to use IotJsonPathContent with the MedTech service device mapping](how-to-use-iotjsonpathcontent-mappings.md)
248247
249248
To learn how to use custom functions with the MedTech service device mapping, see
250249

0 commit comments

Comments
 (0)