Skip to content

Burnrate alerts aren't working correctly #47

@lswith

Description

@lswith

I have an SLO that is 30m (short window) and 6h (long window). I've put the threshold the same on both.

When the SLO was triggered, it was quite quick (within 5m) but the alert took 6 hours to resolve after it went back to normal.

I would have expected it to be resolved quickly according to https://sre.google/workbook/alerting-on-slos/

Looking into this a bit deeper, I think that the threshold values on the monitor take 6 hours to evaluate, and it might not be possible to do "Multiwindow, Multi-Burn-Rate Alerts" using sumologic's monitors.