docs: Migrate thermocycler instruction manual to MkDocs (#19018)
# Overview This migrates content from the Thermocycler GEN2 Instruction Manual to markdown and mkdocs. Most of the content is the same as the manual. Some new changes particularly around the installation procedures and different lid types. Remainder is largely the same. RTC-780, RTC-710 ## Test Plan and Hands on Testing Please check for the usual writing and code stuff. ## Changelog - Flex and OT-2 installation instructions now separate .md files. - Updated lid info, including warnings about using rubber seals and PCR lids at the same time. - Adds information about the new shipping insert that replaces the rubber seal. ## Review requests I no longer have many of the original images. These may be in .indd files. Any problems with images, pull originals from the InDesign files. I do not have this software. ## Risk assessment Docs changes, low risk. --------- Co-authored-by: Ed Cormany <[email protected]>
1 parent 764bee8 commit e273525

38 files changed

+864
-90
lines changed

docs/mkdocs.yml

Lines changed: 1 addition & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -9,6 +9,7 @@ nav:
99
- Modules home: modules/index.md
1010
- Flex Stacker: '!include stacker-manual/mkdocs.yml'
1111
- HEPA/UV Module: '!include hepa-uv/mkdocs.yml'
12+
- Thermocycler Module: '!include thermocycler-manual/mkdocs.yml'
1213
- Python API: https://docs.opentrons.com/v2/
1314

1415
plugins:
Lines changed: 10 additions & 0 deletions
Loading

docs/shared/instruction-manuals.css

Lines changed: 7 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -115,3 +115,10 @@ figure.side-by-side img {
115115
.status-dot.yellow {
116116
background-color: #F09D20;
117117
}
118+
119+
/* Aligns status dots and text if needed*/
120+
.status-dot-container {
121+
display: flex;
122+
align-items: center;
123+
gap: 5px;
124+
}

docs/shared/modules/index.md

Lines changed: 8 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -30,4 +30,12 @@ Opentrons hardware modules add features and capabilities to your robot.
3030

3131
[:octicons-arrow-right-24: Instruction Manual](../hepa-uv/index.md)
3232

33+
- :opentrons-thermocycler:{ .xl .middle } __Thermocycler Module__
34+
35+
---
36+
37+
An automated on-deck thermocycler in a 96-well plate format.
38+
39+
[:octicons-arrow-right-24: Instruction Manual](../thermocycler-manual/index.md)
40+
3341
</div>

docs/stacker-manual/docs/stylesheets/extra.css

Lines changed: 0 additions & 87 deletions
This file was deleted.

docs/stacker-manual/mkdocs.yml

Lines changed: 0 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -11,9 +11,6 @@ theme:
1111
favicon: images/favicon.png
1212
logo: assets/logo.png
1313

14-
extra_css:
15-
- stylesheets/extra.css
16-
1714
markdown_extensions:
1815
- md_in_html
1916
- toc:
Lines changed: 141 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,141 @@
1+
---
2+
title: "Thermocycler Module: Safety and Compliance"
3+
---
4+
5+
# Safety Information and Regulatory Compliance
6+
7+
Opentrons recommends that you follow the safe use specifications in this section and throughout this manual.
8+
9+
## Safe Use Specifications
10+
11+
### Input and Output Connections
12+
13+
The Thermocycler requires the following power input, met by the included power supply.
14+
15+
!!!warning
16+
Do not replace the power supply cable unless directed by Opentrons Support.
17+
18+
### Power supply (AC)
19+
20+
- **Voltage**: 100–240 V
21+
- **Frequency**: 50/60 Hz
22+
- **Current**: 8.5–5 A
23+
- **Overvoltage**: Category II
24+
25+
### Environmental Conditions { #thermocycler-environmental-conditions }
26+
27+
The Thermocycler should only be used indoors on a sturdy, dry, flat horizontal surface. Install this module in a low-vibration environment with stable ambient conditions. Keep it away from direct sunlight or HVAC systems that may cause significant temperature or humidity changes.
28+
29+
!!!note
30+
The Thermocycler should not be powered on or used in conditions outside of the acceptable operating conditions.
31+
32+
The following table defines the environmental standards for recommended use, acceptable use, and storage of your Thermocycler.
33+
34+
| Environmental Conditions | Recommended | Acceptable | Storage and Transportation |
35+
|----|----|----|----|
36+
| Ambient Temperatures | +20 to +25 °C | +2 to +40 °C | –10 to +60 °C |
37+
| Relative Humidity | 30–80%, non-condensing | 30–80%, non-condensing (below 30 °C) | 10–85%, non-condensing (below 30 °C) |
38+
| Altitude | Approximately 500 m above sea level | Up to 2000 m above sea level | Up to 2000 m above sea level |
39+
40+
The following table lists and defines standards for recommended use, acceptable use, and storage.
41+
42+
| Operating Conditions | Description |
43+
|----|----|
44+
| Recommended | Opentrons has validated the Thermocycler’s performance in the conditions recommended for system operation. Operating the Thermocycler in these conditions helps provide optimal results. |
45+
| Acceptable | The Thermocycler is safe to use in conditions acceptable for system operation, but results may vary. |
46+
| Storage | Storage and transportation conditions only apply when the device is completely disconnected from power and other equipment. |
47+
48+
### Low Temperature Condensation
49+
50+
Holding the Thermocycler below ambient temperature for extended periods can cause condensation to develop in and on the device.
51+
52+
!!!warning
53+
Do not set the plate temperature below the ambient temperature for over two hours: condensation could affect performance or damage the module.
54+
55+
### Software Requirements
56+
57+
The Thermocycler requires version 6.2.0 (or higher) of the Opentrons App and robot software. You can download the Opentrons App for Mac, Windows, or Linux at <https://opentrons.com/ot-app>.
58+
59+
### Labware Compatibility
60+
61+
The Thermocycler is compatible with full-skirted, 96-well PCR plates. Performance specifications are based on use with Opentrons Tough PCR Plates, available from the [Tips and Labware section](https://opentrons.com/products/categories/tips-&-labware) of the Opentrons website.
62+
63+
## Module Safety Warnings
64+
65+
Warning symbols posted on the Opentrons Thermocycler and in this manual warn you about sources of potential injury or harm. The following table defines these safety warning symbols.
66+
67+
<table>
68+
<thead>
69+
<tr>
70+
<th>Symbol</th>
71+
<th>Description</th>
72+
</tr>
73+
</thead>
74+
<tbody> <tr>
75+
<td><img src="../images/caution-yellow.svg" alt="Exclamation mark caution symbol"></td>
76+
<td><strong>CAUTION: Injury or damage.</strong><br>
77+
Operating the Opentrons Thermocycler before reading this manual poses a risk of personal injury or instrument damage. Only qualified laboratory personnel should operate this equipment.
78+
</td>
79+
</tr>
80+
<tr>
81+
<td><img src="../images/electric-shock-yellow.svg" alt="Electric shock caution symbol"></td>
82+
<td><strong>CAUTION: Electrical shock.</strong><br>
83+
Do not attempt to repair or remove the outer case of the Opentrons Thermocycler or its power supply unless directed by Opentrons Support. Attempting to do so puts you at risk of electrical shock.
84+
</td>
85+
</tr>
86+
<tr>
87+
<td><img src="../images/hot-surface-yellow.svg" alt="Hot surface caution symbol"></td>
88+
<td><strong>CAUTION: Hot surface.</strong><br>
89+
The Opentrons Thermocycler generates enough heat to cause serious burns. Wear safety goggles or other eye protection at all times during operation. Always ensure the sample block returns to idle temperature before opening the lid and removing samples. Allow maximum clearance to avoid accidental burns. The lid seal can also be hot when opened. Unplug the unit after use, if possible.
90+
</td>
91+
</tr>
92+
<tr>
93+
<td><img src="../images/pinch-yellow.svg" alt="Pinch point caution symbol"></td>
94+
<td><strong>CAUTION: Pinch point.</strong><br>
95+
The lid on the Opentrons Thermocycler presents a pinch point hazard. Keep hands and fingers away from the module while the lid is opening or closing.
96+
</td>
97+
</tr>
98+
<tr>
99+
<td><img src="../images/explosive-yellow.svg" alt="Explosion warning symbol"></td>
100+
<td><strong>CAUTION: Risk of explosion.</strong><br>
101+
Do not operate the Opentrons Thermocycler in areas used for working with explosive substances. Do not process explosive or highly reactive materials in the module or use it with substances that could generate explosive gases.
102+
</td>
103+
</tr>
104+
</tbody>
105+
</table>
106+
107+
## Standards Compliance
108+
109+
The Thermocycler has been tested and found to be in compliance with all applicable requirements of the following safety and electromagnetic standards.
110+
111+
### Safety
112+
113+
- IEC/UL/CSA 61010-1 Safety­ Requirements­ for­ Electrical Equipment­ for Measurement­ Control­ and­ Laboratory Use–­Part­ 1:­ General Requirements
114+
- IEC/UL/CSA­ 61010-2-010­ Particular­ Requirements­ for Laboratory­ Equipment for­ the Heating­ of­ Materials
115+
116+
### Electromagnetic Compatibility
117+
118+
- EN/BSI 61326-1­ Electrical ­ Equipment­ for Measurement Control­ and­ Laboratory­ Use­–EMC Requirements–Part­ 1: General­ Requirements
119+
- EN 55011 Industrial, Scientific and Medical Equipment–Radio Frequency­ Disturbance Characteristics–Limits­ and­ Methods of­ Measurement
120+
- FCC 47CFR Part 15 Subpart B Class A: Unintentional Radiators
121+
- IC ICES-003 Spectrum Management and Telecommunications Interference Causing Equipment Standard–Information Technology Equipment (Including Digital Apparatus)
122+
123+
### FCC Warnings and Notes
124+
125+
**Warning:** Changes or modifications to this unit not expressly approved by Opentrons could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
126+
127+
- This device may not cause harmful interference.
128+
- This device must accept any interference received, including interference that may cause undesired operation.
129+
130+
**Note:** This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide a reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.
131+
132+
### Canada ISED
133+
134+
Canada ICES-003(A)/NMB-003(A)
135+
This­ product­ meets­ the­ applicable­ Innovation,­ Science­ and Economic Development Canada technical specifications.
136+
137+
Le présent produit est conforme aux spécifications techniques applicables d’Innovation, Sciences et Développement économique Canada.
138+
139+
### CISPR 11 Class A
140+
141+
**Caution:** This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Lines changed: 66 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,66 @@
1+
---
2+
title: "Thermocycler Module: Flex Attachment Steps"
3+
---
4+
5+
# Flex Attachment Steps
6+
7+
Setting up the Thermocycler on your robot includes attaching it to the deck and running a first-time calibration process. The instructions here and on the touchscreen will help you get started. The tools you need are included in the User Kit that came with your Flex.
8+
9+
## Attaching the Thermocycler
10+
11+
<div class="instruction-list" markdown>
12+
13+
1. Use a 2.5 mm hex screwdriver to remove the A1 expansion slot plate and the A1 and B1 deck slot plates.
14+
15+
2. Using both hands, lift the module carefully and insert it into its caddy. Make sure the module's exhaust port faces the exhaust duct on the caddy.
16+
17+
3. Use a 2.5 mm hex screwdriver to turn the anchor screws clockwise to tighten the anchors. The module is secure when it doesn't move while gently pulling on it and rocking it from side to side.
18+
19+
4. Connect the USB cable to the module and route the remaining cable through the cable management bracket.
20+
21+
5. Connect the power connector to the module by pressing it firmly into place. Route the remaining cable through the cable management bracket.
22+
23+
6. Insert the caddy, exhaust duct first, into the open deck slot. Route the USB and power cables through the removable side covers as you lower the caddy into position.
24+
25+
7. Connect the USB cable to a USB port on the Flex.
26+
27+
8. Connect the power cable from the module to the external power supply unit. Manually tighten the locking ring to secure it to the power supply.
28+
29+
9. Connect the power supply to a wall outlet and turn on the power supply. If you see a white light on the Thermocycler, it is powered on.
30+
31+
10. Press the illuminated button on the Thermocycler to open the lid.
32+
33+
11. Remove and discard the shipping insert after opening the module's lid. The insert consists of a pad attached to a PCR plate.
34+
35+
![Thermocycler shipping insert](images/shipping-insert.svg)
36+
37+
</div>
38+
39+
When successfully connected, the module appears in the Pipettes and Modules section on your robot's device detail page in the Opentrons App.
40+
41+
Next, you'll calibrate the module.
42+
43+
## Calibrating the Thermocycler
44+
45+
You need to calibrate the Thermocycler after attaching it for the first time. To calibrate the Thermocycler, turn on the power supply. This starts the calibration workflow process on the touchscreen. Instructions on the touchscreen will take you through a guided workflow process, which is also outlined below.
46+
47+
!!!warning
48+
The gantry and pipette move during calibration. Keep your hands clear of the working area before tapping an action button on the touchscreen.
49+
50+
<div class="instruction-list" markdown>
51+
52+
1. Tap **Start setup** on the touchscreen. The robot checks the module's firmware and updates it automatically, if required.
53+
54+
2. Attach the module's calibration adapter and tap **Confirm placement**.
55+
56+
3. Attach the calibration probe to the indicated pipette.
57+
58+
4. Tap **Begin calibration**.
59+
60+
5. After the calibration process is complete, remove the calibration block from the module and remove the calibration probe from the pipette.
61+
62+
6. Click **Exit**.
63+
64+
</div>
65+
66+
Your module is now calibrated. You will not have to recalibrate the same module if you remove and reattach it to the same Flex.

0 commit comments