Skip to content

After reboot, pressure data is missing for several seconds #28

@kedder

Description

@kedder

Apparently #25 introduced a regression: after the boot, sensord does not emit any actual pressure or vario data to the NMEA stream for several seconds. Sometimes the period is quite long - I've seen 20 or 30 seconds.

NMEA stream consist of repeated sentences like

$POV,E,+0.00*39
$POV,P,+994.33,Q,+0.00*4C

This is evident by looking at vario needle in xcsoar: it is frozen at 0 m/s for several seconds after the boot. Reverting 6fa4005 fixes the issue: the pressure/vario data starts coming immediately.

This is also reported in Openvario/meta-openvario#107

@hpmax, can you have a look?

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions