Apparently #25 introduced a regression: after the boot, sensord does not emit any actual pressure or vario data to the NMEA stream for several seconds. Sometimes the period is quite long - I've seen 20 or 30 seconds.
NMEA stream consist of repeated sentences like
$POV,E,+0.00*39
$POV,P,+994.33,Q,+0.00*4C
This is evident by looking at vario needle in xcsoar: it is frozen at 0 m/s for several seconds after the boot. Reverting 6fa4005 fixes the issue: the pressure/vario data starts coming immediately.
This is also reported in Openvario/meta-openvario#107
@hpmax, can you have a look?