user-guide/01-getting-started/01-assembly_guides/00_pioreactor_40ml_v1.5/03-40ml-v15-wetware-assembly.md

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -60,7 +60,7 @@ The vial holder comes in two halves; a top vial holder and a bottom vial holder.
6060

6161
1. Insert the other end of the flex cable below the O-ring and into <Highlight color={colors.red}>the groove</Highlight>. Pull it through.
6262
2. <Highlight color={colors.magenta}>Apply pressure</Highlight> on the back of the heater PCB so that it lies flat on the O-ring. Maintain this pressure for the next steps.
63-
3. **While maintaining pressure**, flip the holder and insert the two <Highlight color={colors.green}>M2.5-CS 4mm screws</Highlight> into the holes - **don't tighten fully yet**.
63+
3. **While maintaining pressure**, flip the holder and insert the two <Highlight color={colors.green}>M2.5-CS 6mm screws</Highlight> into the holes (heads up: your screws might be brass, not black) - **don't tighten fully yet**.
6464
4. **While maintaining pressure**, take turns screwing each in until both are reasonably tight, and the heater PCB is securely attached to the bottom vial holder.
6565

6666
</AssemblyInstructionBlock>

user-guide/01-getting-started/01-assembly_guides/00_pioreactor_40ml_v1.5/05-40ml-v15-optics-assembly.md

Lines changed: 0 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -17,11 +17,6 @@ import * as colors from '@site/src/components/constants';
1717
* <Highlight color={colors.blue}>Eye-spy covers (3x)</Highlight>
1818
* <Highlight color={colors.red}>8mm screws (12x)</Highlight>
1919
* <Highlight color={colors.magenta}>Eye-spies (2x)</Highlight>
20-
21-
:::tip
22-
Each eye-spy is unique. The one used for REF has a white mark in the upper-left corner.
23-
:::
24-
2520
* <Highlight color={colors.teal}>100mm STEMMA-QT wire</Highlight>
2621
* <Highlight color={colors.orange}>50mm STEMMA-QT wire</Highlight>
2722
* <Highlight color={colors.green}>LED cable</Highlight>

user-guide/01-getting-started/01-assembly_guides/01_pioreactor_20ml_v1.5/03-20ml-v15-wetware-assembly.md

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -55,7 +55,7 @@ import TabItem from '@theme/TabItem';
5555

5656
1. Insert the other end of the flex cable below the O-ring and into <Highlight color={colors.red}>the groove</Highlight>. Pull it through.
5757
2. <Highlight color={colors.magenta}>Apply pressure</Highlight> on the back of the heater PCB so that it lies flat on the O-ring. Maintain this pressure for the next steps.
58-
3. **While maintaining pressure**, flip the holder and insert the two <Highlight color={colors.green}>M2.5-CS 4mm screws</Highlight> into the holes - **don't tighten fully yet**.
58+
3. **While maintaining pressure**, flip the holder and insert the two <Highlight color={colors.green}>M2.5-CS 6mm screws</Highlight> (heads up: your screws might be brass, not black) into the holes - **don't tighten fully yet**.
5959
4. **While maintaining pressure**, take turns screwing each in until both are reasonably tight, and the heater PCB is securely attached to the bottom vial holder.
6060

6161
</AssemblyInstructionBlock>

user-guide/01-getting-started/01-assembly_guides/01_pioreactor_20ml_v1.5/05-20ml-v15-optics-assembly.md

Lines changed: 0 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -16,11 +16,6 @@ import * as colors from '@site/src/components/constants';
1616
* <Highlight color={colors.blue}>Eye-spy covers (3x)</Highlight>
1717
* <Highlight color={colors.red}>8mm screws (12x)</Highlight>
1818
* <Highlight color={colors.magenta}>Eye-spies (2x)</Highlight>
19-
20-
:::tip
21-
Each eye-spy is unique. The one used for REF has a white mark in the upper-left corner.
22-
:::
23-
2419
* <Highlight color={colors.teal}>100mm Stemma-QT wire</Highlight>
2520
* <Highlight color={colors.orange}>50mm Stemma-QT wire</Highlight>
2621
* <Highlight color={colors.green}>LED cable</Highlight>

user-guide/01-getting-started/01-assembly_guides/06_pioreactor_20ml_v1.1_to_v1.5/05-20ml-v15-optics-assembly.md

Lines changed: 0 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -16,11 +16,6 @@ import * as colors from '@site/src/components/constants';
1616
* <Highlight color={colors.blue}>Eye-spy covers (3x)</Highlight>
1717
* <Highlight color={colors.red}>8mm screws (12x)</Highlight>
1818
* <Highlight color={colors.magenta}>Eye-spies (2x)</Highlight>
19-
20-
:::tip
21-
Each eye-spy is unique. The one used for REF has a white mark in the upper-left corner.
22-
:::
23-
2419
* <Highlight color={colors.teal}>100mm Stemma-QT wire</Highlight>
2520
* <Highlight color={colors.orange}>50mm Stemma-QT wire</Highlight>
2621
* <Highlight color={colors.green}>LED cable</Highlight>

user-guide/01-getting-started/01-assembly_guides/07_pioreactor_40ml_v1.0_to_v1.5/05-40ml-v15-optics-assembly.md

Lines changed: 0 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -17,11 +17,6 @@ import * as colors from '@site/src/components/constants';
1717
* <Highlight color={colors.blue}>Eye-spy covers (3x)</Highlight>
1818
* <Highlight color={colors.red}>8mm screws (12x)</Highlight>
1919
* <Highlight color={colors.magenta}>Eye-spies (2x)</Highlight>
20-
21-
:::tip
22-
Each eye-spy is unique. The one used for REF has a white mark in the upper-left corner.
23-
:::
24-
2520
* <Highlight color={colors.teal}>100mm STEMMA-QT wire</Highlight>
2621
* <Highlight color={colors.orange}>50mm STEMMA-QT wire</Highlight>
2722
* <Highlight color={colors.green}>LED cable</Highlight>

0 commit comments

Comments
 (0)