diff --git a/src/power_grid_model_io/converters/pandapower_converter.py b/src/power_grid_model_io/converters/pandapower_converter.py index 1c22dac4..86f44a28 100644 --- a/src/power_grid_model_io/converters/pandapower_converter.py +++ b/src/power_grid_model_io/converters/pandapower_converter.py @@ -1744,7 +1744,7 @@ def _pp_buses_output_3ph(self): pp_output_buses_3ph["va_b_degree"] = node_u_angle[:, 1] * (180.0 / np.pi) pp_output_buses_3ph["vm_c_pu"] = node_u_pu[:, 2] pp_output_buses_3ph["va_c_degree"] = node_u_angle[:, 2] * (180.0 / np.pi) - pp_output_buses_3ph["unbalance_percent"] = np.abs(u_sequence[:, 0]) / np.abs(u_sequence[:, 1]) * 100 + pp_output_buses_3ph["unbalance_percent"] = np.abs(u_sequence[:, 2]) / np.abs(u_sequence[:, 1]) * 100 # p_to, p_from, q_to and q_from connected to the bus have to be summed up self._pp_buses_output_3ph__accumulate_power(pp_output_buses_3ph) @@ -1878,10 +1878,10 @@ def _pp_lines_output_3ph(self): "i_b_to_ka", "i_c_to_ka", "i_n_to_ka", - "loading_percent", "loading_a_percent", "loading_b_percent", "loading_c_percent", + "loading_percent", ], index=self._get_pp_ids("line", pgm_output_lines["id"]), )