You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Copy file name to clipboardExpand all lines: outputs/US/costs_2020.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -3721,15 +3721,15 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
3721
3721
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3722
3722
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3723
3723
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
3724
-
central water pit storage,Energy losses during storage,0.0043,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3724
+
central water pit storage,Energy losses during storage,,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3725
3725
central water pit storage,FOM,0.2354,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3726
3726
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
3727
3727
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
3728
3728
central water pit storage,investment,1.0622,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3729
3729
central water pit storage,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
3730
3730
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3731
3731
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3732
-
central water tank storage,Energy losses during storage,0.0077,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3732
+
central water tank storage,Energy losses during storage,0.0077,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3733
3733
central water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
3734
3734
central water tank storage,Temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
3735
3735
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2020.0,,
@@ -3833,7 +3833,7 @@ decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cos
3833
3833
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0,,
3834
3834
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3835
3835
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3836
-
decentral water tank storage,Energy losses during storage,2.1,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
3836
+
decentral water tank storage,Energy losses during storage,2.1,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
3837
3837
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
3838
3838
decentral water tank storage,Temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
3839
3839
decentral water tank storage,VOM,0.7168,EUR/MWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2020.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2025.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -3801,15 +3801,15 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
3801
3801
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3802
3802
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3803
3803
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
3804
-
central water pit storage,Energy losses during storage,0.0043,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3804
+
central water pit storage,Energy losses during storage,,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3805
3805
central water pit storage,FOM,0.2354,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3806
3806
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
3807
3807
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
3808
3808
central water pit storage,investment,1.0622,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3809
3809
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
3810
3810
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3811
3811
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3812
-
central water tank storage,Energy losses during storage,0.0077,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3812
+
central water tank storage,Energy losses during storage,0.0077,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3813
3813
central water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
3814
3814
central water tank storage,Temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
3815
3815
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2020.0,,
@@ -3919,7 +3919,7 @@ decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cos
3919
3919
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0,,
3920
3920
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3921
3921
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3922
-
decentral water tank storage,Energy losses during storage,2.1,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
3922
+
decentral water tank storage,Energy losses during storage,2.1,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
3923
3923
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
3924
3924
decentral water tank storage,Temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
3925
3925
decentral water tank storage,VOM,0.8704,EUR/MWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2020.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2030.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -3957,15 +3957,15 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
3957
3957
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3958
3958
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3959
3959
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
3960
-
central water pit storage,Energy losses during storage,0.0043,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3960
+
central water pit storage,Energy losses during storage,,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3961
3961
central water pit storage,FOM,0.2354,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3962
3962
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
3963
3963
central water pit storage,energy to power ratio,30.0,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
3964
3964
central water pit storage,investment,1.0622,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3965
3965
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
3966
3966
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3967
3967
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3968
-
central water tank storage,Energy losses during storage,0.0077,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3968
+
central water tank storage,Energy losses during storage,0.0077,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3969
3969
central water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
3970
3970
central water tank storage,Temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
3971
3971
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2020.0,,
@@ -4075,7 +4075,7 @@ decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cos
4075
4075
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0,,
4076
4076
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
4077
4077
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
4078
-
decentral water tank storage,Energy losses during storage,2.1,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
4078
+
decentral water tank storage,Energy losses during storage,2.1,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
4079
4079
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
4080
4080
decentral water tank storage,Temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
4081
4081
decentral water tank storage,VOM,1.0241,EUR/MWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2020.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2035.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -3981,15 +3981,15 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
3981
3981
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3982
3982
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3983
3983
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
3984
-
central water pit storage,Energy losses during storage,0.0043,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3984
+
central water pit storage,Energy losses during storage,,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3985
3985
central water pit storage,FOM,0.2354,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3986
3986
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
3987
3987
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
3988
3988
central water pit storage,investment,1.0622,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3989
3989
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
3990
3990
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3991
3991
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3992
-
central water tank storage,Energy losses during storage,0.0077,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3992
+
central water tank storage,Energy losses during storage,0.0077,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Energy losses during storage,2020.0,,
3993
3993
central water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
3994
3994
central water tank storage,Temperature difference,55.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Typical temperature difference,2020.0,,
3995
3995
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2020.0,,
@@ -4099,7 +4099,7 @@ decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cos
4099
4099
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0,,
4100
4100
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
4101
4101
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
4102
-
decentral water tank storage,Energy losses during storage,2.1,%/h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
4102
+
decentral water tank storage,Energy losses during storage,2.1,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Energy losses during storage,2020.0,,
4103
4103
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0,,
4104
4104
decentral water tank storage,Temperature difference,30.0,"hot/cold, K","Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Typical temperature difference,2020.0,,
4105
4105
decentral water tank storage,VOM,1.1265,EUR/MWh,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2020.0,,
0 commit comments