You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
* Updated excel columns for pit thermal energy storage and recompiled costs
* [pre-commit.ci] auto fixes from pre-commit.com hooks
for more information, see https://pre-commit.ci
* add release note
---------
Co-authored-by: cpschau <[email protected]>
Co-authored-by: pre-commit-ci[bot] <66853113+pre-commit-ci[bot]@users.noreply.github.com>
Copy file name to clipboardExpand all lines: docs/release_notes.rst
+3Lines changed: 3 additions & 0 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -16,6 +16,9 @@ Upcoming Release
16
16
.. The features listed below are not released yet, but will be part of the next release!
17
17
.. To use the features already you have to use the ``master`` branch.
18
18
19
+
* Updated indexing of DEA Excel data for PTES and revised capital cost and FOM assumptions for 2045 and 2050.
20
+
21
+
19
22
* Corrected units for standing losses of TES technologies from per unit to %/hour and changed parameter names from "Energy losses during storage" to "standing losses" as well as "Temperature difference" to "temperature difference" for naming consistency.
Copy file name to clipboardExpand all lines: outputs/US/costs_2045.csv
+2-2Lines changed: 2 additions & 2 deletions
Original file line number
Diff line number
Diff line change
@@ -3981,10 +3981,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
3981
3981
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3982
3982
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3983
3983
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
3984
-
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3984
+
central water pit storage,FOM,0.2652,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3985
3985
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
3986
3986
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
3987
-
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3987
+
central water pit storage,investment,0.9427,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3988
3988
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
3989
3989
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3990
3990
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2050.csv
+2-2Lines changed: 2 additions & 2 deletions
Original file line number
Diff line number
Diff line change
@@ -3981,10 +3981,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
3981
3981
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
3982
3982
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
3983
3983
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
3984
-
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3984
+
central water pit storage,FOM,0.2769,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
3985
3985
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
3986
3986
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
3987
-
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3987
+
central water pit storage,investment,0.9029,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
3988
3988
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
3989
3989
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
3990
3990
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
Copy file name to clipboardExpand all lines: outputs/costs_2045.csv
+2-2Lines changed: 2 additions & 2 deletions
Original file line number
Diff line number
Diff line change
@@ -825,10 +825,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
825
825
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
826
826
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0
827
827
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0
828
-
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
828
+
central water pit storage,FOM,0.2652,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
829
829
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0
830
830
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0
831
-
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
831
+
central water pit storage,investment,0.9427,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
832
832
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0
833
833
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0
834
834
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
Copy file name to clipboardExpand all lines: outputs/costs_2050.csv
+2-2Lines changed: 2 additions & 2 deletions
Original file line number
Diff line number
Diff line change
@@ -825,10 +825,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
825
825
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
826
826
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0
827
827
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0
828
-
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
828
+
central water pit storage,FOM,0.2769,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
829
829
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0
830
830
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0
831
-
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
831
+
central water pit storage,investment,0.9029,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
832
832
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0
833
833
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0
834
834
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
0 commit comments