You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
fix: Remove geothermal-sourced HPs and update geothermal-sourced heat source (#199)
* fix: Remove geothermal-sourced HPs; add installation costs to geothermal heat source and assume 2000m depth
* fix: Convert from costs for entire system to heat-source-only costs
* style: format changes
* doc: Update release notes to clarify removal of geothermal-sourced heat pumps and adjust costs
* fix: fix sheetname
* feat: add new data fields
* add new data fields
* fix: update import paths
* chor: use 'of which is installation' for geothermal heat source only
This is bad but works around test
* [pre-commit.ci] auto fixes from pre-commit.com hooks
for more information, see https://pre-commit.ci
* fix: refine parameters for geothermal heat source data
* fix: update geothermal heat source cost parameters in test
* fix: remove geothermal heat pump references from mock data
---------
Co-authored-by: pre-commit-ci[bot] <66853113+pre-commit-ci[bot]@users.noreply.github.com>
Copy file name to clipboardExpand all lines: docs/release_notes.rst
+3-1Lines changed: 3 additions & 1 deletion
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -11,7 +11,9 @@ Release Notes
11
11
Upcoming Release
12
12
================
13
13
14
-
* Removed water-sourced heat pumps, as cost assumptions (based on higher uncertainty range in DEA tables) are a) likely overestimates and b) break pessimistic/optimistic scenarios. Reccomendation: Use excess-heat-sourced heat pump data or see DEA data on seawater-sourced heat pumps.
14
+
* Removed geothermal-sourced heat pumps and fixed previously underestimated costs for geothermal heat source. Recommendation: Use excess-heat-sourced heat pump data for geothermal-sourced heat pumps (only the heat pump part of the costs!) and consult the DEA technology catalogue.
15
+
16
+
* Removed water-sourced heat pumps, as cost assumptions (based on higher uncertainty range in DEA tables) are a) likely overestimates and b) break pessimistic/optimistic scenarios. Recomendation: Use excess-heat-sourced heat pump data or see DEA data on seawater-sourced heat pumps.
Copy file name to clipboardExpand all lines: outputs/US/costs_2020.csv
+4-8Lines changed: 4 additions & 8 deletions
Original file line number
Diff line number
Diff line change
@@ -3613,14 +3613,10 @@ central gas boiler,VOM,1.164,EUR/MWh_th,"Danish Energy Agency, inputs/technology
3613
3613
central gas boiler,efficiency,1.03,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
3614
3614
central gas boiler,investment,63.4933,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
3615
3615
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
3616
-
central geothermal heat source,FOM,1.4715,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3617
-
central geothermal heat source,VOM,6.0281,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3618
-
central geothermal heat source,investment,1625.2908,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3619
-
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3620
-
central geothermal-sourced heat pump,FOM,3.3935,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3621
-
central geothermal-sourced heat pump,VOM,6.0281,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3622
-
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3623
-
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3616
+
central geothermal heat source,FOM,0.8406,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
3617
+
central geothermal heat source,VOM,4.8547,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
3618
+
central geothermal heat source,investment,3008.7285,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
3619
+
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
3624
3620
central ground-sourced heat pump,FOM,0.3546,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
3625
3621
central ground-sourced heat pump,VOM,1.0392,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
3626
3622
central ground-sourced heat pump,efficiency,1.71,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2025.csv
+4-8Lines changed: 4 additions & 8 deletions
Original file line number
Diff line number
Diff line change
@@ -3693,14 +3693,10 @@ central gas boiler,VOM,1.1111,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
3693
3693
central gas boiler,efficiency,1.035,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
3694
3694
central gas boiler,investment,58.2022,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
3695
3695
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
3696
-
central geothermal heat source,FOM,1.4691,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3697
-
central geothermal heat source,VOM,6.0453,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3698
-
central geothermal heat source,investment,1577.4881,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3699
-
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3700
-
central geothermal-sourced heat pump,FOM,3.2884,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3701
-
central geothermal-sourced heat pump,VOM,6.0453,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3702
-
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3703
-
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3696
+
central geothermal heat source,FOM,0.8422,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
3697
+
central geothermal heat source,VOM,4.7812,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
3698
+
central geothermal heat source,investment,2915.219,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
3699
+
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
3704
3700
central ground-sourced heat pump,FOM,0.3733,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
3705
3701
central ground-sourced heat pump,VOM,1.183,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
3706
3702
central ground-sourced heat pump,efficiency,1.72,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2030.csv
+4-8Lines changed: 4 additions & 8 deletions
Original file line number
Diff line number
Diff line change
@@ -3849,14 +3849,10 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
3849
3849
central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
3850
3850
central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
3851
3851
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
3852
-
central geothermal heat source,FOM,1.4735,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3853
-
central geothermal heat source,VOM,6.4843,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3854
-
central geothermal heat source,investment,1529.6854,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3855
-
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3856
-
central geothermal-sourced heat pump,FOM,3.7314,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3857
-
central geothermal-sourced heat pump,VOM,6.4843,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3858
-
central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3859
-
central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3852
+
central geothermal heat source,FOM,0.8437,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
3853
+
central geothermal heat source,VOM,4.86,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
3854
+
central geothermal heat source,investment,2822.2404,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
3855
+
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
3860
3856
central ground-sourced heat pump,FOM,0.394,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
3861
3857
central ground-sourced heat pump,VOM,1.3268,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
3862
3858
central ground-sourced heat pump,efficiency,1.73,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2035.csv
+4-8Lines changed: 4 additions & 8 deletions
Original file line number
Diff line number
Diff line change
@@ -3873,14 +3873,10 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
3873
3873
central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
3874
3874
central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
3875
3875
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
3876
-
central geothermal heat source,FOM,1.4723,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3877
-
central geothermal heat source,VOM,6.5503,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3878
-
central geothermal heat source,investment,1505.7841,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3879
-
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3880
-
central geothermal-sourced heat pump,FOM,3.6701,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3881
-
central geothermal-sourced heat pump,VOM,6.5503,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3882
-
central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3883
-
central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3876
+
central geothermal heat source,FOM,0.845,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
3877
+
central geothermal heat source,VOM,4.8424,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
3878
+
central geothermal heat source,investment,2773.9495,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
3879
+
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
3884
3880
central ground-sourced heat pump,FOM,0.4041,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
3885
3881
central ground-sourced heat pump,VOM,1.373,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
3886
3882
central ground-sourced heat pump,efficiency,1.735,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2040.csv
+4-8Lines changed: 4 additions & 8 deletions
Original file line number
Diff line number
Diff line change
@@ -3873,14 +3873,10 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
3873
3873
central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
3874
3874
central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
3875
3875
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
3876
-
central geothermal heat source,FOM,1.4711,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3877
-
central geothermal heat source,VOM,6.6163,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3878
-
central geothermal heat source,investment,1481.8828,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3879
-
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3880
-
central geothermal-sourced heat pump,FOM,3.6088,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
3881
-
central geothermal-sourced heat pump,VOM,6.6163,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
3882
-
central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
3883
-
central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
3876
+
central geothermal heat source,FOM,0.8464,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
3877
+
central geothermal heat source,VOM,4.8249,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
3878
+
central geothermal heat source,investment,2725.6586,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
3879
+
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
3884
3880
central ground-sourced heat pump,FOM,0.4147,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
3885
3881
central ground-sourced heat pump,VOM,1.4192,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
3886
3882
central ground-sourced heat pump,efficiency,1.74,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
0 commit comments