Skip to content

Commit f1dfcb6

Browse files
Merge branch 'master' into add-additional-heat-pumps
2 parents 55a331f + 4efd377 commit f1dfcb6

File tree

12 files changed

+74
-4
lines changed

12 files changed

+74
-4
lines changed

.github/dependabot.yml

Lines changed: 14 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,14 @@
1+
# dependabot
2+
# Ref: https://docs.github.com/en/code-security/dependabot/dependabot-version-updates/configuration-options-for-the-dependabot.yml-file
3+
# ------------------------------------------------------------------------------
4+
version: 2
5+
updates:
6+
- package-ecosystem: github-actions
7+
directory: /
8+
schedule:
9+
interval: monthly
10+
groups:
11+
# open a single pull-request for all GitHub actions updates
12+
github-actions:
13+
patterns:
14+
- '*'

.github/workflows/ci.yaml

Lines changed: 3 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -6,8 +6,8 @@ jobs:
66
build:
77
runs-on: ubuntu-latest
88
steps:
9-
- uses: actions/checkout@v2
10-
- uses: mamba-org/setup-micromamba@v1
9+
- uses: actions/checkout@v4
10+
- uses: mamba-org/setup-micromamba@v2
1111
with:
1212
micromamba-version: latest
1313
environment-file: environment.yaml
@@ -20,7 +20,7 @@ jobs:
2020
run: |
2121
snakemake --cores all -f compile_cost_assumptions
2222
- name: Upload artifacts
23-
uses: actions/upload-artifact@v3
23+
uses: actions/upload-artifact@v4
2424
with:
2525
name: technology-data
2626
path: outputs/

docs/release_notes.rst

Lines changed: 4 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -19,6 +19,10 @@ Release Notes
1919

2020
* Fix minor issues in the code
2121

22+
* fix minor issues in the code
23+
24+
* added iron-air battery cost data from Form Energy
25+
2226

2327
Technology-Data 0.9.2 (30 August 2024)
2428
======================================
522 KB
Binary file not shown.

inputs/manual_input.csv

Lines changed: 18 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -386,4 +386,21 @@ fuelwood,fuel,2050,10.5474097062402,EUR/MWhth,2010,"JRC ENSPRESO ca avg for MINB
386386
allam,investment,2030,1500,EUR/kW,2020,Own assumption. TODO: Find better technology data and cost assumptions,
387387
allam,VOM,2030,2,EUR/MWh,2020,Own assumption. TODO: Find better technology data and cost assumptions,
388388
allam,efficiency,2030,0.6,p.u.,2020,Own assumption. TODO: Find better technology data and cost assumptions,
389-
allam,lifetime,2030,30,years,2020,Own assumption. TODO: Find better technology data and cost assumptions,
389+
allam,lifetime,2030,30,years,2020,Own assumption. TODO: Find better technology data and cost assumptions,
390+
iron-air battery,FOM,2025,1.02185373078457,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
391+
iron-air battery,FOM,2030,1,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
392+
iron-air battery,FOM,2035,1.10628646943421,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
393+
iron-air battery,FOM,2040,1.1807773334732,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
394+
iron-air battery,investment,2025,23.45,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
395+
iron-air battery,investment,2030,15.61,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
396+
iron-air battery,investment,2035,11.79,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
397+
iron-air battery,investment,2040,10.40,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
398+
iron-air battery charge,efficiency,2025,0.70,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
399+
iron-air battery charge,efficiency,2030,0.71,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
400+
iron-air battery charge,efficiency,2035,0.73,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
401+
iron-air battery charge,efficiency,2040,0.74,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
402+
iron-air battery discharge,efficiency,2025,0.59,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
403+
iron-air battery discharge,efficiency,2030,0.60,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
404+
iron-air battery discharge,efficiency,2035,0.62,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
405+
iron-air battery discharge,efficiency,2040,0.63,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
406+
iron-air battery,lifetime,2030,17.5,years,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",

outputs/costs_2020.csv

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -940,6 +940,11 @@ industrial heat pump medium temperature,efficiency,2.55,per unit,"Danish Energy
940940
industrial heat pump medium temperature,investment,877.2984,EUR/kW,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0
941941
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0
942942
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0
943+
iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
944+
iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
945+
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
946+
iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
947+
iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
943948
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,
944949
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0
945950
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0

outputs/costs_2025.csv

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -940,6 +940,11 @@ industrial heat pump medium temperature,efficiency,2.625,per unit,"Danish Energy
940940
industrial heat pump medium temperature,investment,830.775,EUR/kW,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0
941941
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0
942942
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0
943+
iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
944+
iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
945+
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
946+
iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
947+
iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
943948
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,
944949
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0
945950
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0

outputs/costs_2030.csv

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -940,6 +940,11 @@ industrial heat pump medium temperature,efficiency,2.7,per unit,"Danish Energy A
940940
industrial heat pump medium temperature,investment,784.2516,EUR/kW,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0
941941
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0
942942
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0
943+
iron-air battery,FOM,1.0,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
944+
iron-air battery,investment,15.61,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
945+
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
946+
iron-air battery charge,efficiency,0.71,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
947+
iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
943948
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,
944949
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0
945950
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0

outputs/costs_2035.csv

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -940,6 +940,11 @@ industrial heat pump medium temperature,efficiency,2.75,per unit,"Danish Energy
940940
industrial heat pump medium temperature,investment,759.6808,EUR/kW,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0
941941
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0
942942
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0
943+
iron-air battery,FOM,1.1063,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
944+
iron-air battery,investment,11.79,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
945+
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
946+
iron-air battery charge,efficiency,0.73,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
947+
iron-air battery discharge,efficiency,0.62,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
943948
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,
944949
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0
945950
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0

outputs/costs_2040.csv

Lines changed: 5 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -940,6 +940,11 @@ industrial heat pump medium temperature,efficiency,2.8,per unit,"Danish Energy A
940940
industrial heat pump medium temperature,investment,735.11,EUR/kW,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0
941941
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0
942942
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0
943+
iron-air battery,FOM,1.1808,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
944+
iron-air battery,investment,10.4,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
945+
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
946+
iron-air battery charge,efficiency,0.74,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
947+
iron-air battery discharge,efficiency,0.63,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0
943948
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,
944949
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0
945950
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0

0 commit comments

Comments
 (0)