diff --git a/docs/release_notes.rst b/docs/release_notes.rst index cf22cb66..e76cfa4c 100644 --- a/docs/release_notes.rst +++ b/docs/release_notes.rst @@ -16,6 +16,9 @@ Upcoming Release .. The features listed below are not released yet, but will be part of the next release! .. To use the features already you have to use the ``master`` branch. +* Updated indexing of DEA Excel data for PTES and revised capital cost and FOM assumptions for 2045 and 2050. + + * Corrected units for standing losses of TES technologies from per unit to %/hour and changed parameter names from "Energy losses during storage" to "standing losses" as well as "Temperature difference" to "temperature difference" for naming consistency. diff --git a/outputs/US/costs_2045.csv b/outputs/US/costs_2045.csv index 836a28d8..671823e6 100644 --- a/outputs/US/costs_2045.csv +++ b/outputs/US/costs_2045.csv @@ -3981,10 +3981,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,, central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,, central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,, -central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,, +central water pit storage,FOM,0.2652,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,, central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,, central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,, -central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,, +central water pit storage,investment,0.9427,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,, central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,, central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,, central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,, diff --git a/outputs/US/costs_2050.csv b/outputs/US/costs_2050.csv index 588b3882..52d01ad9 100644 --- a/outputs/US/costs_2050.csv +++ b/outputs/US/costs_2050.csv @@ -3981,10 +3981,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,, central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,, central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,, -central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,, +central water pit storage,FOM,0.2769,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,, central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,, central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,, -central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,, +central water pit storage,investment,0.9029,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,, central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,, central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,, central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,, diff --git a/outputs/costs_2045.csv b/outputs/costs_2045.csv index f579d8a0..c61c1ac7 100644 --- a/outputs/costs_2045.csv +++ b/outputs/costs_2045.csv @@ -825,10 +825,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0 central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0 central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0 -central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0 +central water pit storage,FOM,0.2652,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0 central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0 central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0 -central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0 +central water pit storage,investment,0.9427,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0 central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0 central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0 central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0 diff --git a/outputs/costs_2050.csv b/outputs/costs_2050.csv index fb4a58e9..9a02b4ba 100644 --- a/outputs/costs_2050.csv +++ b/outputs/costs_2050.csv @@ -825,10 +825,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0 central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0 central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0 -central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0 +central water pit storage,FOM,0.2769,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0 central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0 central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0 -central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0 +central water pit storage,investment,0.9029,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0 central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0 central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0 central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0 diff --git a/scripts/compile_cost_assumptions.py b/scripts/compile_cost_assumptions.py index e4a269de..7e3b60a0 100644 --- a/scripts/compile_cost_assumptions.py +++ b/scripts/compile_cost_assumptions.py @@ -189,7 +189,7 @@ "direct firing solid fuels CC": "H:I", "decentral ground-sourced heat pump": "I:J", "decentral air-sourced heat pump": "I:J", - "central water pit storage": "J:K", + "central water pit storage": "I:L", "central water tank storage": "J:K", "decentral water tank storage": "J:K", "fuel cell": "I:J", @@ -670,6 +670,10 @@ def get_data_DEA( "gas storage", ]: usecols = "B:F" + elif tech_name in [ + "central water pit storage", + ]: + usecols = "B:H" else: usecols = "B:G"