Skip to content

Exporting to Java syntax messes up uncertainty units #21

@rwest

Description

@rwest

Import this:

533.    C_methane   C2b                 294-376     7.5e12  0.0  0  1.05       1.6e12  0.0 0   0.12 4   Matsugi et al 10.1021/jp1012494

and you get this

    kinetics = ArrheniusEP(
        A = (7500000000000.0, 'cm^3/(mol*s)', '+|-', 1600000000000.0),
        n = 0,
        alpha = 0,
        E0 = (1.05, 'kcal/mol', '+|-', 0.12),
        Tmin = (294, 'K'),
        Tmax = (376, 'K'),
    ),

which becomes this

533   C_methane    C2b   294-376  7.50e+12  0.00  0.00  1.05 1.6e+18  0  0 2.86807e-05   4   Matsugi et al 10.1021/jp1012494

when you export it again.
The uncertainty on A is six orders of magnitude larger (m3/cm3), and on Ea is 4184 times smaller (J/kCal).