Skip to content

Commit 0bb8e9b

Browse files
cazoubroonie
authored andcommitted
ASoC: sgtl5000: Reset the CHIP_CLK_CTRL reg on remove
Since commit bf2aebc ("ASoC: sgtl5000: Fix noise on shutdown/remove"), the device power control registers are reset when the driver is removed/shutdown. This is an issue when the device is configured to use the PLL clock. The device will stop responding if it is still configured to use the PLL clock but the PLL clock is powered down. When rebooting linux, the probe function will show: sgtl5000 0-000a: Error reading chip id -11 Make sure that the CHIP_CLK_CTRL is reset to its default value before powering down the device. Fixes: bf2aebc ("ASoC: sgtl5000: Fix noise on shutdown/remove") Signed-off-by: Detlev Casanova <[email protected]> Reviewed-by: Fabio Estevam <[email protected]> Link: https://lore.kernel.org/r/[email protected] Signed-off-by: Mark Brown <[email protected]>
1 parent 3788210 commit 0bb8e9b

File tree

1 file changed

+1
-0
lines changed

1 file changed

+1
-0
lines changed

sound/soc/codecs/sgtl5000.c

Lines changed: 1 addition & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -1794,6 +1794,7 @@ static void sgtl5000_i2c_remove(struct i2c_client *client)
17941794
{
17951795
struct sgtl5000_priv *sgtl5000 = i2c_get_clientdata(client);
17961796

1797+
regmap_write(sgtl5000->regmap, SGTL5000_CHIP_CLK_CTRL, SGTL5000_CHIP_CLK_CTRL_DEFAULT);