block: don't set GD_NEED_PART_SCAN if scan partition failed
Currently if disk_scan_partitions() failed, GD_NEED_PART_SCAN will still
set, and partition scan will be proceed again when blkdev_get_by_dev()
is called. However, this will cause a problem that re-assemble partitioned
raid device will creat partition for underlying disk.
Test procedure:
mdadm -CR /dev/md0 -l 1 -n 2 /dev/sda /dev/sdb -e 1.0
sgdisk -n 0:0:+100MiB /dev/md0
blockdev --rereadpt /dev/sda
blockdev --rereadpt /dev/sdb
mdadm -S /dev/md0
mdadm -A /dev/md0 /dev/sda /dev/sdb
Test result: underlying disk partition and raid partition can be
observed at the same time
Note that this can still happen in come corner cases that
GD_NEED_PART_SCAN can be set for underlying disk while re-assemble raid
device.
Fixes: e5cfefa ("block: fix scan partition for exclusively open device again")
Reviewed-by: Jan Kara <[email protected]>
Reviewed-by: Ming Lei <[email protected]>
Signed-off-by: Yu Kuai <[email protected]>
Signed-off-by: Jens Axboe <[email protected]>