HID: nintendo: check analog user calibration for plausibility
Arne Wendt writes:
Cheap clone controllers may (falsely) report as having a user
calibration for the analog sticks in place, but return
wrong/impossible values for the actual calibration data.
In the present case at mine, the controller reports having a
user calibration in place and successfully executes the read
commands. The reported user calibration however is
min = center = max = 0.
This pull request addresses problems of this kind by checking the
provided user calibration-data for plausibility (min < center < max)
and falling back to the default values if implausible.
I'll note that I was experiencing a crash because of this bug when using
the GuliKit KingKong 2 controller. The crash manifests as a divide by
zero error in the kernel logs:
kernel: divide error: 0000 [#1] PREEMPT SMP NOPTI
Link: nicman23/dkms-hid-nintendo#25
Link: DanielOgorchock/linux#36
Co-authored-by: Arne Wendt <[email protected]>
Signed-off-by: Johnothan King <[email protected]>
Signed-off-by: Benjamin Tissoires <[email protected]>
Link: https://lore.kernel.org/r/gvpL2G6VwXGJPvxX5KRiu9pVjvTivgayug_jdKDY6zfuAaAqncP9BkKLosjwUXNlgVVTMfJSKfwPF1K79cKAkwGComyC21vCV3q9B3EXNkE=@protonmail.com