According to the "i.MX 6UltraLite Applications Processor Reference Manual,
Rev. 2, 03/2017", BIT(13) is ENET1_125M_EN which is not controlling root
of PLL6. It is controlling ENET1 separately.
So, instead of this picture (implementation before this patch):
fec1 <- enet_ref (divider) <---------------------------,
|- pll6_enet (gate)
fec2 <- enet2_ref_125m (gate) <- enet2_ref (divider) <-´
we should have this one (after this patch):
fec1 <- enet1_ref_125m (gate) <- enet1_ref (divider) <-,
|- pll6_enet
fec2 <- enet2_ref_125m (gate) <- enet2_ref (divider) <-´
With this fix, the RMII reference clock will be turned off, after
setting network interface down on each separate interface
(ip l s dev eth0 down). Which was not working before, on system with both
FECs enabled.
Signed-off-by: Oleksij Rempel <[email protected]>
Reviewed-by: Abel Vesa <[email protected]>
Signed-off-by: Abel Vesa <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
0 commit comments