dt-bindings: mailbox: Add mediatek,gce-props.yaml
Add mediatek,gce-props.yaml for common GCE properties that is used for both mailbox providers and consumers. We place the common property "mediatek,gce-events" in this binding currently. The property "mediatek,gce-events" is used for GCE event ID corresponding to a hardware event signal sent by the hardware or a software driver. If the mailbox providers or consumers want to manipulate the value of the event ID, they need to know the specific event ID. Signed-off-by: Jason-JH.Lin <[email protected]> Reviewed-by: Conor Dooley <[email protected]> Reviewed-by: AngeloGioacchino Del Regno <[email protected]> Signed-off-by: Jassi Brar <[email protected]>
1 parent 256abd8 commit d1368f6

File tree

1 file changed

+52
-0
lines changed

1 file changed

+52
-0
lines changed
Lines changed: 52 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,52 @@
1+
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
2+
%YAML 1.2
3+
---
4+
$id: http://devicetree.org/schemas/mailbox/mediatek,gce-props.yaml#
5+
$schema: http://devicetree.org/meta-schemas/core.yaml#
6+
7+
title: MediaTek Global Command Engine Common Properties
8+
9+
maintainers:
10+
- Houlong Wei <[email protected]>
11+
12+
description:
13+
The Global Command Engine (GCE) is an instruction based, multi-threaded,
14+
single-core command dispatcher for MediaTek hardware. The Command Queue
15+
(CMDQ) mailbox driver is a driver for GCE, implemented using the Linux
16+
mailbox framework. It is used to receive messages from mailbox consumers
17+
and configure GCE to execute the specified instruction set in the message.
18+
We use mediatek,gce-mailbox.yaml to define the properties for CMDQ mailbox
19+
driver. A device driver that uses the CMDQ driver to configure its hardware
20+
registers is a mailbox consumer. The mailbox consumer can request a mailbox
21+
channel corresponding to a GCE hardware thread to send a message, specifying
22+
that the GCE thread to configure its hardware. The mailbox provider can also
23+
reserve a mailbox channel to configure GCE hardware register by the specific
24+
GCE thread. This binding defines the common GCE properties for both mailbox
25+
provider and consumers.
26+
27+
properties:
28+
mediatek,gce-events:
29+
description:
30+
GCE has an event table in SRAM, consisting of 1024 event IDs (0~1023).
31+
Each event ID has a boolean event value with the default value 0.
32+
The property mediatek,gce-events is used to obtain the event IDs.
33+
Some gce-events are hardware-bound and cannot be changed by software.
34+
For instance, in MT8195, when VDO0_MUTEX is stream done, VDO_MUTEX will
35+
send an event signal to GCE, setting the value of event ID 597 to 1.
36+
Similarly, in MT8188, the value of event ID 574 will be set to 1 when
37+
VOD0_MUTEX is stream done.
38+
On the other hand, some gce-events are not hardware-bound and can be
39+
changed by software. For example, in MT8188, we can set the value of
40+
event ID 855, which is not bound to any hardware, to 1 when the driver
41+
in the secure world completes a task. However, in MT8195, event ID 855
42+
is already bound to VDEC_LAT1, so we need to select another event ID to
43+
achieve the same purpose. This event ID can be any ID that is not bound
44+
to any hardware and is not yet used in any software driver.
45+
To determine if the event ID is bound to the hardware or used by a
46+
software driver, refer to the GCE header
47+
include/dt-bindings/gce/<chip>-gce.h of each chip.
48+
$ref: /schemas/types.yaml#/definitions/uint32-array
49+
minItems: 1
50+
maxItems: 32
51+
52+
additionalProperties: true

0 commit comments

Comments
 (0)