That --checkPowerMode report sounds like it will always be correct, a drive will be in either of those states. If that's what the drive says, that's what the drive says and we can search on the net to infer that means the drive is not idle thanks to a couple of other openSeaChest issues here on GitHub, but something more clear would be nice.
I've got 3 Exos X18 ST16000NM000J-2TW103 with firmware SN04, and 1 X24 ST16000NM002H-3KW133 with firmware RE05. All are fine with Idle A and Idle B enabled, the X24 is new and currently stuck in this reported state after changing to 4K sector size yesterday. One new x18 probably did that starting a couple of weeks ago, the others have been in service for a year and a half. Today all the x18s flip between idle and that report that if I read from them.
A note on the factory settings, none of the times match the manuals except for Idle A. Idle C and Standby Z are not enabled which is good for a default, the X18s Idle B are set to 1200, 12 seconds, the X24 is set to 6000, 1 minute. The manuals say it should be 2 minutes.
If you care about drive longevity that might be diminished by many head load cycles, and minor power savings don't matter to you, is there a recommended setting for Idle B? Any reason not to disable Idle B and keep the heads flying at all times, or will that wear out the media faster and effectively cut into the 550TB/year maximum for these drives?