| 1 | +Version: 7.2.10.7895 |
| 2 | +Installer: |
| 3 | +- InstallerUrl: https://www.picoauto.com/download/software/sr/PicoScope_7_Automotive_7.2.10.7895.x64.exe |
| 4 | +Locale: |
| 5 | +- Locale: en-US |
| 6 | + Key: ReleaseNotes |
| 7 | + Value: |- |
| 8 | + New features |
| 9 | + - NOTE: From this version, PS7 will no longer install on MS Windows 7, 8, 8.1 and the earliest release versions of 10. |
| 10 | + - A new Channel Deskew control has been integrated into the Channel Display tabs. |
| 11 | + - A new Waveform Overlay tool allows multiple scope or spectrum traces to be overlaid using controls in the Waveform Navigator, enabling range selection to identify anomalies or visualize changes over time. |
| 12 | + - The amplitude strategy (Top/Base or Peak-to-Peak) can now be selected for Rise/Fall Time and Rise/Fall Rate measurements and math channels. |
| 13 | + - Measurements can now be selected or deselected to show or hide their graph indicators, with only one measurements indicators displayed at a time. This is currently supported for Pk-Pk, Min, Max, Edge Count, Cycle Time, Frequency, Pulse Width, Rise/Fall Time, Rise/Fall Rate, RMS, RMS ripple, Top/Base, Amplitude, Mean, Phase, Delay, Duty Cycle, Overshoot and Crest Factor measurements. The feature can be enabled or disabled in Add Measurement > Settings. |
| 14 | + - Serial decoder filters now display the filtered data on the graph. |
| 15 | + - Serial decoding filter settings are now saved within .psdata and .pssettings files. |
| 16 | + - Added an isoSPI decoder to Serial Decoding. |
| 17 | + - Actions can now be configured to trigger when a measurement passes or fails its limit, either for specific measurements or across all added measurements. |
| 18 | + - Ruler values are now included in printouts, when printing to PDF and when copying as image. |
| 19 | + - Phase rulers can now be locked together when moving them. |
| 20 | + - Ruler delta and tracking ruler values can now be selected and copied. |
| 21 | + - Waveform capture times can now be exported to a CSV file via the Waveform Navigator and Save dialog. |
| 22 | + - A new tool button has been added to return to factory settings, alongside the existing Reset Configuration control, which restores settings from the start of the session (Factory, User-defined, or Last Session settings). |
| 23 | + - Measurements, Notes and Ruler information is now appended when saving as PNG. |
| 24 | + - Spectrum view data can now be exported to the Matlab file format. |
| 25 | + - Reference waveform delay adjustment has been improved to cover the entire current capture time. |
| 26 | + - Setup Wizard has been added to the top toolbar for quick access. |
| 27 | + - Numeric values can now be fine-adjusted by holding the SHIFT key while using the + / - buttons or mouse wheel. |
| 28 | + - Some translations updates. |
| 29 | +
|
| 30 | + Bug fixes |
| 31 | + - Resolved an issue where the trace could flicker when zooming in Persistence mode. |
| 32 | + - Spectrum views now update correctly when the number of bins is changed after stopping a capture. |
| 33 | + - Resolved an issue where the Start Up/Down control in Spectrum skipped a value when clicking the - button. |
| 34 | + - Resolved an issue when exporting serial decoded data in ODS file format. |
| 35 | + - Fixed an issue in which Serial Decoding settings were not saved when channels were disabled and re-enabled. |
| 36 | + - Resolved an issue where Auto Range did not function with overranged input when a linear probe was in use. |
| 37 | + - Improvements to edge count measurement stability. |
| 38 | + - Resolved an issue where only a single buffer could be captured in certain situations. |
| 39 | + - Various timestamp-related fixes have been implemented. |
| 40 | + - Improvements have been made to address slow or unresponsive rulers when used with math channels and large datasets. |
| 41 | + - Saving user default .pssettings files no longer causes subsequent customer data file saves to default to AppData\Local\Pico Technology. |
| 42 | + - Fixed a hang when trying to export large captures with maths channels to csv. |
| 43 | + - Resolved an issue when loading files containing serial decoded data saved in older PS7 versions. |
| 44 | + - Fixed a software hang that occurred during the export of large captures containing math channels to CSV format. |
| 45 | + - Resolved an issue where actions triggered by a mask limit test results could become unsynchronized. |
| 46 | + - Resolved an issue where the "Stop Capture" action in Actions would not trigger in certain situations. |
| 47 | + - Resolved an issue where part of the trace could temporarily disappear when zooming with multiple viewports. |
| 48 | + - Tabbed viewports now display graphs correctly when loading files. |
| 49 | + - Resolved an issue that made graph adornments difficult to move when using touch controls. |
| 50 | + - Some general performance optimisations when opening the Save dialog, when using the Waveform Navigator and after capturing with Rapid trigger. |
| 51 | + - General stability fixes have been applied. |
| 52 | + - [Toolbox] PicoScope 7 and Toolbox are now aligned, allowing selection of engine capacities up to 150 litres. |
| 53 | + - [Toolbox] The Maximise button no longer closes Toolbox. |
| 54 | + - [PicoDiagnostics] Compression test translation has been fixed for Italian. |
| 55 | + - [PicoDiagnostics] Resolved an issue where road speed vibration orders were displayed incorrectly. |
| 56 | + - [PicoDiagnostics] Resolved an issue where RP1210 devices were not displaying the port. |
| 57 | + - [PicoDiagnostics] Resolved an issue where the crash reporter was not displayed when PicoDiagnostics crashed. |
| 58 | + - [PicoDiagnostics] Resolved an issue with ELM327 connections. |
| 59 | + - [PicoDiagnostics] Resolved multiple NVH powertrain view issues. |
| 60 | + - [PicoDiagnostics] Accelerometer calibration support reinstated. |
| 61 | + - [PicoDiagnostics] RP1210 bug fixes. |
| 62 | + - [PicoDiagnostics] Minor updates to improve stability. |
| 63 | + - [PicoDiagnostics] Other general bug fixes. |
| 64 | + - [PicoDiagnostics] Improved debug logging. |
| 65 | +ReleaseTime: 2025-12-11T00:00:00.0000000Z |