-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathProject_Full_Script.sql
More file actions
540 lines (461 loc) · 13.8 KB
/
Project_Full_Script.sql
File metadata and controls
540 lines (461 loc) · 13.8 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
CREATE DATABASE SmartHomeDB;
GO
USE SmartHomeDB;
GO
CREATE TABLE Users (
UserID INT PRIMARY KEY IDENTITY(1,1),
Username VARCHAR(50) NOT NULL UNIQUE,
PasswordHash VARCHAR(256) NOT NULL,
FullName VARCHAR(100) NOT NULL,
Role VARCHAR(20) NOT NULL CHECK (Role IN ('Admin', 'Member')),
CreatedAt DATETIME DEFAULT GETDATE()
);
GO
CREATE TABLE Rooms (
RoomID INT PRIMARY KEY IDENTITY(1,1),
RoomName VARCHAR(50) NOT NULL,
FloorNumber INT NOT NULL DEFAULT 1
);
GO
CREATE TABLE DeviceTypes (
TypeID INT PRIMARY KEY IDENTITY(1,1),
TypeName VARCHAR(50) NOT NULL UNIQUE,
Description VARCHAR(200) NULL
);
GO
USE SmartHomeDB;
GO
CREATE TABLE Devices (
DeviceID INT PRIMARY KEY IDENTITY(1,1),
DeviceName VARCHAR(100) NOT NULL,
TypeID INT NOT NULL,
RoomID INT NOT NULL,
CurrentStatus VARCHAR(50) DEFAULT 'OFF',
IsActive BIT DEFAULT 1,
FOREIGN KEY (TypeID) REFERENCES DeviceTypes(TypeID),
FOREIGN KEY (RoomID) REFERENCES Rooms(RoomID)
);
GO
CREATE TABLE SensorReadings (
ReadingID BIGINT PRIMARY KEY IDENTITY(1,1),
DeviceID INT NOT NULL,
ReadingValue FLOAT NOT NULL,
Unit VARCHAR(20) NOT NULL,
RecordedAt DATETIME DEFAULT GETDATE(),
FOREIGN KEY (DeviceID) REFERENCES Devices(DeviceID)
);
GO
CREATE TABLE Scenes (
SceneID INT PRIMARY KEY IDENTITY(1,1),
SceneName VARCHAR(50) NOT NULL,
CreatedBy INT NOT NULL,
CreatedAt DATETIME DEFAULT GETDATE(),
FOREIGN KEY (CreatedBy) REFERENCES Users(UserID)
);
GO
CREATE TABLE SceneActions (
ActionID INT PRIMARY KEY IDENTITY(1,1),
SceneID INT NOT NULL,
DeviceID INT NOT NULL,
TargetStatus VARCHAR(50) NULL,
TargetValue FLOAT NULL,
FOREIGN KEY (SceneID) REFERENCES Scenes(SceneID),
FOREIGN KEY (DeviceID) REFERENCES Devices(DeviceID)
);
GO
CREATE TABLE AutomationRules (
RuleID INT PRIMARY KEY IDENTITY(1,1),
RuleName VARCHAR(100) NOT NULL,
TriggerDeviceID INT NOT NULL,
ConditionOperator VARCHAR(5) NOT NULL,
ThresholdValue FLOAT NOT NULL,
ActionSceneID INT NOT NULL,
FOREIGN KEY (TriggerDeviceID) REFERENCES Devices(DeviceID),
FOREIGN KEY (ActionSceneID) REFERENCES Scenes(SceneID)
);
GO
USE SmartHomeDB;
GO
-- 1. Insert Users
INSERT INTO Users (Username, PasswordHash, FullName, Role) VALUES
('admin', 'hash123', 'System Administrator', 'Admin'),
('john_doe', 'pass456', 'John Doe', 'Member'),
('jane_doe', 'pass789', 'Jane Doe', 'Member'),
('guest_user', 'guest000', 'Guest', 'Member'),
('kid_user', 'kid111', 'Kid Account', 'Member');
GO
-- 2. Insert Rooms
INSERT INTO Rooms (RoomName, FloorNumber) VALUES
('Living Room', 1),
('Kitchen', 1),
('Master Bedroom', 2),
('Kids Bedroom', 2),
('Garage', 0);
GO
-- 3. Insert DeviceTypes
INSERT INTO DeviceTypes (TypeName, Description) VALUES
('Smart Light', 'Adjustable LED Light'),
('Thermostat', 'Temperature Control Unit'),
('Motion Sensor', 'Detects movement'),
('Smart Lock', 'Electronic Door Lock'),
('Security Camera', 'HD IP Camera');
GO
-- 4. Insert Devices
-- Assumes IDs 1-5 generated above correspond to the order of insertion
INSERT INTO Devices (DeviceName, TypeID, RoomID, CurrentStatus, IsActive) VALUES
('Living Room Main Light', 1, 1, 'ON', 1),
('Kitchen Thermostat', 2, 2, '22.5', 1),
('Front Door Lock', 4, 1, 'LOCKED', 1),
('Garage Motion Sensor', 3, 5, 'NO_MOTION', 1),
('Master Bedroom Light', 1, 3, 'OFF', 1),
('Backyard Camera', 5, 5, 'RECORDING', 1),
('Kids Room Light', 1, 4, 'ON', 1);
GO
-- 5. Insert Sensor Readings
INSERT INTO SensorReadings (DeviceID, ReadingValue, Unit) VALUES
(2, 22.5, 'Celsius'),
(2, 22.8, 'Celsius'),
(2, 23.0, 'Celsius'),
(2, 21.5, 'Celsius'),
(4, 1.0, 'Boolean'); -- 1 for Motion Detected
GO
-- 6. Insert Scenes
INSERT INTO Scenes (SceneName, CreatedBy) VALUES
('Good Night', 1),
('Away Mode', 1),
('Movie Time', 2),
('Morning Routine', 3),
('Party Mode', 1);
GO
-- 7. Insert Scene Actions
-- Defines what happens when "Good Night" (SceneID 1) runs
INSERT INTO SceneActions (SceneID, DeviceID, TargetStatus, TargetValue) VALUES
(1, 1, 'OFF', NULL), -- Turn off Living Room Light
(1, 3, 'LOCKED', NULL), -- Lock Front Door
(1, 5, 'OFF', NULL), -- Turn off Master Bedroom Light
(3, 1, 'DIM', 20.0), -- Dim lights for Movie Time
(2, 2, 'ECO', 18.0); -- Set Thermostat to 18 for Away Mode
GO
-- 8. Insert Automation Rules
INSERT INTO AutomationRules (RuleName, TriggerDeviceID, ConditionOperator, ThresholdValue, ActionSceneID) VALUES
('Auto Cool Down', 2, '>', 28.0, 2), -- If Temp > 28, trigger Away/Cool scene
('Intruder Alert', 4, '=', 1.0, 2), -- If Motion=1, trigger Away Mode (as example)
('Night Lock', 3, '=', 0.0, 1),
('Morning Warmup', 2, '<', 18.0, 4),
('Camera Rec on Motion', 4, '=', 1.0, 2);
GO
USE SmartHomeDB;
GO
-- =============================================
-- SECTION A: VIEWS (3 Items)
-- =============================================
-- 1. View_FullDeviceDetails
CREATE VIEW View_FullDeviceDetails AS
SELECT
d.DeviceID,
d.DeviceName,
dt.TypeName,
r.RoomName,
r.FloorNumber,
d.CurrentStatus,
d.IsActive
FROM Devices d
INNER JOIN Rooms r ON d.RoomID = r.RoomID
INNER JOIN DeviceTypes dt ON d.TypeID = dt.TypeID;
GO
-- 2. View_CriticalSensors
CREATE VIEW View_CriticalSensors AS
SELECT
sr.ReadingID,
d.DeviceName,
r.RoomName,
sr.ReadingValue,
sr.Unit,
sr.RecordedAt
FROM SensorReadings sr
INNER JOIN Devices d ON sr.DeviceID = d.DeviceID
INNER JOIN Rooms r ON d.RoomID = r.RoomID
WHERE
(sr.Unit = 'Celsius' AND sr.ReadingValue > 28.0) OR
(sr.Unit = 'Boolean' AND sr.ReadingValue = 1.0);
GO
-- 3. View_RoomSummary
CREATE VIEW View_RoomSummary AS
SELECT
r.RoomName,
COUNT(d.DeviceID) AS TotalDevices,
SUM(CASE WHEN d.CurrentStatus != 'OFF' THEN 1 ELSE 0 END) AS ActiveDevices
FROM Rooms r
LEFT JOIN Devices d ON r.RoomID = d.RoomID
GROUP BY r.RoomName;
GO
-- =============================================
-- SECTION B: FUNCTIONS (3 Items)
-- =============================================
-- 1. Fn_GetRoomAverageTemp (Scalar Function)
CREATE FUNCTION Fn_GetRoomAverageTemp (@RoomID INT)
RETURNS FLOAT
AS
BEGIN
DECLARE @AvgTemp FLOAT;
SELECT @AvgTemp = AVG(sr.ReadingValue)
FROM SensorReadings sr
INNER JOIN Devices d ON sr.DeviceID = d.DeviceID
WHERE d.RoomID = @RoomID AND sr.Unit = 'Celsius';
RETURN ISNULL(@AvgTemp, 0);
END;
GO
-- 2. Fn_GetDevicesByType (Table-Valued Function)
CREATE FUNCTION Fn_GetDevicesByType (@TypeName VARCHAR(50))
RETURNS TABLE
AS
RETURN (
SELECT d.DeviceID, d.DeviceName, r.RoomName, d.CurrentStatus
FROM Devices d
INNER JOIN DeviceTypes dt ON d.TypeID = dt.TypeID
INNER JOIN Rooms r ON d.RoomID = r.RoomID
WHERE dt.TypeName = @TypeName
);
GO
-- 3. Fn_IsDeviceActive (Scalar Function - Boolean Logic)
CREATE FUNCTION Fn_IsDeviceActive (@DeviceID INT)
RETURNS BIT
AS
BEGIN
DECLARE @Status VARCHAR(50);
DECLARE @IsActive BIT;
SELECT @Status = CurrentStatus FROM Devices WHERE DeviceID = @DeviceID;
IF @Status IN ('OFF', '0', 'NO_MOTION', 'LOCKED')
SET @IsActive = 0;
ELSE
SET @IsActive = 1;
RETURN @IsActive;
END;
GO
USE SmartHomeDB;
GO
CREATE TABLE SystemLogs (
LogID INT PRIMARY KEY IDENTITY(1,1),
LogMessage NVARCHAR(255),
LogDate DATETIME DEFAULT GETDATE()
);
GO
-- SECTION A: STORED PROCEDURES
-- 1. SP_ActivateScene
CREATE PROCEDURE SP_ActivateScene
@SceneID INT
AS
BEGIN
SET NOCOUNT ON;
UPDATE d
SET
d.CurrentStatus = sa.TargetStatus,
d.IsActive = 1
FROM Devices d
INNER JOIN SceneActions sa ON d.DeviceID = sa.DeviceID
WHERE sa.SceneID = @SceneID AND sa.TargetStatus IS NOT NULL;
INSERT INTO SystemLogs (LogMessage)
VALUES ('Scene Activated: ' + CAST(@SceneID AS VARCHAR(10)));
PRINT 'Scene executed successfully.';
END;
GO
-- 2. SP_RegisterNewDevice
CREATE PROCEDURE SP_RegisterNewDevice
@DeviceName VARCHAR(100),
@TypeID INT,
@RoomID INT
AS
BEGIN
IF NOT EXISTS (SELECT 1 FROM DeviceTypes WHERE TypeID = @TypeID)
BEGIN
PRINT 'Error: Invalid Device Type ID.';
RETURN;
END
INSERT INTO Devices (DeviceName, TypeID, RoomID, CurrentStatus)
VALUES (@DeviceName, @TypeID, @RoomID, 'OFF');
PRINT 'Device registered successfully.';
END;
GO
-- 3. SP_RecordSensorReading
CREATE PROCEDURE SP_RecordSensorReading
@DeviceID INT,
@Value FLOAT,
@Unit VARCHAR(20)
AS
BEGIN
INSERT INTO SensorReadings (DeviceID, ReadingValue, Unit)
VALUES (@DeviceID, @Value, @Unit);
IF (@Unit = 'Celsius' AND @Value > 30.0)
BEGIN
PRINT 'WARNING: High temperature detected!';
END
END;
GO
-- SECTION B: TRIGGERS (3 Items)
-- 1. TRG_AuditDeviceStatus
CREATE TRIGGER TRG_AuditDeviceStatus
ON Devices
AFTER UPDATE
AS
BEGIN
SET NOCOUNT ON;
IF UPDATE(CurrentStatus)
BEGIN
INSERT INTO SystemLogs (LogMessage)
SELECT
'Device ' + CAST(i.DeviceID AS VARCHAR(10)) +
' changed from ' + d.CurrentStatus +
' to ' + i.CurrentStatus
FROM inserted i
JOIN deleted d ON i.DeviceID = d.DeviceID;
END
END;
GO
-- 2. TRG_PreventCriticalDelete
CREATE TRIGGER TRG_PreventCriticalDelete
ON Devices
INSTEAD OF DELETE
AS
BEGIN
SET NOCOUNT ON;
IF EXISTS (SELECT 1 FROM deleted WHERE CurrentStatus IN ('LOCKED', 'ON', 'RECORDING'))
BEGIN
RAISERROR ('Cannot delete active or locked devices. Turn them OFF first.', 16, 1);
END
ELSE
BEGIN
DELETE FROM Devices WHERE DeviceID IN (SELECT DeviceID FROM deleted);
PRINT 'Device deleted successfully.';
END
END;
GO
-- 3. TRG_AutoSecurityAlert
CREATE TRIGGER TRG_AutoSecurityAlert
ON SensorReadings
AFTER INSERT
AS
BEGIN
SET NOCOUNT ON;
IF EXISTS (SELECT 1 FROM inserted WHERE Unit = 'Boolean' AND ReadingValue = 1.0)
BEGIN
INSERT INTO SystemLogs (LogMessage)
SELECT 'SECURITY ALERT: Motion detected on device ' + CAST(DeviceID AS VARCHAR(10))
FROM inserted
WHERE Unit = 'Boolean' AND ReadingValue = 1.0;
END
END;
GO
USE SmartHomeDB;
GO
PRINT '--- STARTING SYSTEM TESTS ---';
EXEC SP_RegisterNewDevice 'New Smart TV', 1, 1;
PRINT 'Test 1: Device Registered.';
EXEC SP_ActivateScene 1;
PRINT 'Test 2: Scene Activated.';
SELECT * FROM SystemLogs;
BEGIN TRY
DELETE FROM Devices WHERE DeviceName = 'Front Door Lock';
END TRY
BEGIN CATCH
PRINT 'Test 4 Success: Prevented deletion of locked device. Error: ' + ERROR_MESSAGE();
END CATCH;
INSERT INTO SensorReadings (DeviceID, ReadingValue, Unit)
VALUES (4, 1.0, 'Boolean');
SELECT * FROM SystemLogs ORDER BY LogDate DESC;
PRINT '--- TESTS COMPLETED ---';
USE SmartHomeDB;
GO
ALTER TABLE Devices
ADD DeviceCode AS (UPPER(SUBSTRING(DeviceName, 1, 3)) + '-' + CAST(RoomID AS VARCHAR) + '-' + CAST(DeviceID AS VARCHAR));
GO
CREATE NONCLUSTERED INDEX IX_SensorReadings_DeviceID
ON SensorReadings(DeviceID);
GO
CREATE NONCLUSTERED INDEX IX_Devices_RoomID
ON Devices(RoomID);
GO
DECLARE @i INT = 1;
DECLARE @RandDeviceID INT;
DECLARE @RandValue FLOAT;
DECLARE @RandTemp FLOAT;
WHILE @i <= 100
BEGIN
SET @RandDeviceID = FLOOR(RAND() * 5) + 1;
SET @RandTemp = CAST(18 + (RAND() * 15) AS DECIMAL(4,1));
IF @RandDeviceID = 2
BEGIN
INSERT INTO SensorReadings (DeviceID, ReadingValue, Unit, RecordedAt)
VALUES (@RandDeviceID, @RandTemp, 'Celsius', DATEADD(MINUTE, -@i, GETDATE()));
END
ELSE IF @RandDeviceID = 4
BEGIN
INSERT INTO SensorReadings (DeviceID, ReadingValue, Unit, RecordedAt)
VALUES (@RandDeviceID, FLOOR(RAND() * 2), 'Boolean', DATEADD(MINUTE, -@i, GETDATE()));
END
ELSE
BEGIN
INSERT INTO SensorReadings (DeviceID, ReadingValue, Unit, RecordedAt)
VALUES (@RandDeviceID, 0, 'Generic', DATEADD(MINUTE, -@i, GETDATE()));
END
SET @i = @i + 1;
END;
GO
USE SmartHomeDB;
GO
-- =============================================
-- 1. CTE (Common Table Expression)
-- =============================================
WITH RoomActivityCounts AS (
SELECT
r.RoomName,
COUNT(sr.ReadingID) AS TotalReadings
FROM Rooms r
JOIN Devices d ON r.RoomID = d.RoomID
JOIN SensorReadings sr ON d.DeviceID = sr.DeviceID
GROUP BY r.RoomName
)
SELECT * FROM RoomActivityCounts
WHERE TotalReadings > 0
ORDER BY TotalReadings DESC;
GO
-- =============================================
-- 2. Window Function (ROW_NUMBER)
-- =============================================
SELECT DeviceName, ReadingValue, Unit, RecordedAt
FROM (
SELECT
d.DeviceName,
sr.ReadingValue,
sr.Unit,
sr.RecordedAt,
ROW_NUMBER() OVER (PARTITION BY d.DeviceID ORDER BY sr.RecordedAt DESC) AS RowNum
FROM Devices d
JOIN SensorReadings sr ON d.DeviceID = sr.DeviceID
) AS RankedReadings
WHERE RowNum = 1;
GO
-- =============================================
-- 3.Subquery, EXISTS
-- =============================================
SELECT DeviceName, RoomName
FROM Devices d
JOIN Rooms r ON d.RoomID = r.RoomID
WHERE NOT EXISTS (
SELECT 1
FROM SensorReadings sr
WHERE sr.DeviceID = d.DeviceID
);
GO
-- =============================================
-- 4. Group By, HAVING
-- =============================================
SELECT
d.DeviceName,
AVG(sr.ReadingValue) AS AvgTemp,
MAX(sr.ReadingValue) AS MaxTemp
FROM SensorReadings sr
JOIN Devices d ON sr.DeviceID = d.DeviceID
WHERE sr.Unit = 'Celsius'
GROUP BY d.DeviceName
HAVING AVG(sr.ReadingValue) > 25.0;
GO