Skip to content

Charging current for Swiss T13 sockets too high during battery calibration | Zendure SolarFlow 2400 AC #58

@hoinmic

Description

@hoinmic

Device: Zendure SolarFlow 2400 AC

The battery calibration process automatically triggered by Zendure charges at 2400W. The “T13” power sockets in Switzerland are not designed to withstand this continuous load.

Product standard (SN 441011): The T13 socket is designed for a rated current of 10 A. However, according to the underlying test standard, household sockets must only be able to carry this rated current for a limited period of time (typically 1 hour) without excessive heating.

It is extremely dangerous to use the 2400W charging power constantly for several hours for calibration!

The charging power must be adjustable to a lower setting, otherwise Swiss T13 sockets may catch fire!