diff --git a/testing_results/testing_results_v2.0.0-beta-rc2/plugins/pqm/pqm_tests.rst b/testing_results/testing_results_v2.0.0-beta-rc2/plugins/pqm/pqm_tests.rst index 5f4c29389f..5602a22fce 100644 --- a/testing_results/testing_results_v2.0.0-beta-rc2/plugins/pqm/pqm_tests.rst +++ b/testing_results/testing_results_v2.0.0-beta-rc2/plugins/pqm/pqm_tests.rst @@ -21,11 +21,11 @@ Rms tool - Scopy version - Plugin version (N/A if not applicable) - Comments - * - - - - - - - - - + * - Andrei-Fabian Pop + - 17.02.2025 + - v2.0.0-beta-rc2-a3a7c43 + - N/A + - None Setup environment: ^^^^^^^^^^^^^^^^^^ @@ -65,14 +65,14 @@ accessible without errors. and a Settings button. The Settings menu is open, and the Settings button is in a checked state. In the center of the widget, there are two plots, each with labels positioned above them. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -82,7 +82,7 @@ accessible without errors. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -109,14 +109,14 @@ Test 2: Info button check. 2. Click on the **Info** button. - **Expected result:** The RMS documentation page is opened in the browser. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -126,7 +126,7 @@ Test 2: Info button check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -153,14 +153,14 @@ Test 3: Single acquisition. 2. Click on the **Single** button. - **Expected result:** Both the plot and the header labels are populated with values. A single block of data is acquired. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -170,7 +170,7 @@ Test 3: Single acquisition. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -199,7 +199,7 @@ Test 4: Data acquisition. 2. Click on the **Start** button. - **Expected result:** Both the plot and the header labels are populated with values. The data is updated every few seconds. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -207,14 +207,14 @@ Test 4: Data acquisition. 3. Click on the **Stop** button. - **Expected result:** The data acquisition stops. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -224,7 +224,7 @@ Test 4: Data acquisition. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -251,14 +251,14 @@ Test 5: Settings button check. 2. Click on the **Settings** button. - **Expected result:** The settings menu collapses and the button becomes unchecked. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -268,7 +268,7 @@ Test 5: Settings button check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -297,7 +297,7 @@ Test 6: Data logging. - If data acquisition is running, the log section cannot be accessed. 4. Click on the **LOG** switch button. - **Expected result:** A browse section is displayed. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. @@ -306,7 +306,7 @@ Test 6: Data logging. 5. Click on the **Browse** button. - **Expected result:** A explorer window is displayed. Only directories can be selected. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -315,7 +315,7 @@ Test 6: Data logging. 6. Select a directory and click on the **Open** button. - **Expected result:** The explorer window is closed and the path to that directory is introduced in the browser section. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -325,7 +325,7 @@ Test 6: Data logging. - **Expected result:** The **LOG** section remains open, but its elements can no longer be accessed and a .csv file is created in the selected directory. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -334,14 +334,14 @@ Test 6: Data logging. 8. Click on the **Stop** button. - **Expected result:** The **LOG** section can now be accessed, and the .csv file is populated with data. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -351,7 +351,7 @@ Test 6: Data logging. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -380,7 +380,7 @@ Test 7: Data logging wrong path. - If data acquisition is running, the log section cannot be accessed. 4. Click on the **LOG** switch button. - **Expected result:** A browse section is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -390,7 +390,7 @@ Test 7: Data logging wrong path. 6. Click on the **Run** button. - **Expected result:** The **LOG** section get closed and no .csv file is created. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -398,14 +398,14 @@ Test 7: Data logging wrong path. 7. Click on the **Stop** button. - **Expected result:** The **LOG** section remains closed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -415,7 +415,7 @@ Test 7: Data logging wrong path. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -442,7 +442,7 @@ Test 8: PQEvents. 2. Click on the **Run** button. 3. Run ``iio_attr -u ip:127.0.0.1 -c pqm count0 countEvent 1`` command. - **Expected result:** The PQEvents indicator becomes active. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -450,7 +450,7 @@ Test 8: PQEvents. 4. Click on the **Stop** button. - **Expected result:** The PQEvents indicator is still active. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -458,7 +458,7 @@ Test 8: PQEvents. 5. Click on the **PQEvents** indicator. - **Expected result:** The PQEvents indicator becomes inactive. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -466,7 +466,7 @@ Test 8: PQEvents. 6. Run ``iio_attr -u ip:127.0.0.1 -c pqm count0 countEvent 0`` command. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -476,7 +476,7 @@ Test 8: PQEvents. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -500,11 +500,11 @@ Harmonics tool - Scopy version - Plugin version (N/A if not applicable) - Comments - * - - - - - - - - - + * - Andrei-Fabian Pop + - 17.02.2025 + - v2.0.0-beta-rc2-a3a7c43 + - N/A + - None Setup environment: ^^^^^^^^^^^^^^^^^^ @@ -544,14 +544,14 @@ and is accessible without errors. and a Settings button. The Settings menu is open, and the Settings button is in a checked state. In the center, there are three components: THD, a table, and a plot. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -561,7 +561,7 @@ and is accessible without errors. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -588,14 +588,14 @@ Test 2: Info button check. 2. Click on the **Info** button. - **Expected result:** The Harmonics documentation page is opened in the browser. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -605,7 +605,7 @@ Test 2: Info button check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -635,14 +635,14 @@ Test 3: Single acquisition. - **Expected result:** All the components are populated with values. The data in the table must be reflected on the plot. A single block of data is acquired. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -652,7 +652,7 @@ Test 3: Single acquisition. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -682,7 +682,7 @@ Test 4: Data acquisition. - **Expected result:** The data is updated every few seconds (only the values from the table and from the plot are updated). The data in the table must be reflected on the plot. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -690,14 +690,14 @@ Test 4: Data acquisition. 3. Click on the **Stop** button. - **Expected result:** The data acquisition stops. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -707,7 +707,7 @@ Test 4: Data acquisition. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -734,7 +734,7 @@ Test 5: The features of the table. 2. Click on the **Single** button. - **Expected result:** The row Ia is highlighted and the corresponding values are drawn on the plot. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -744,7 +744,7 @@ Test 5: The features of the table. 4. Click on the **Ib** row from the table. - **Expected result:** The entire row is selected and the Ib values are displayed on the plot. In the setting menu, the active channel is also Ib. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -754,14 +754,14 @@ Test 5: The features of the table. - **Expected result:** Only the respective values remain highlighted, and only the selected columns appear on the plot. The drawing color is another one. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -771,7 +771,7 @@ Test 5: The features of the table. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -798,7 +798,7 @@ Test 6: Settings button check. 2. Click on the **Settings** button. - **Expected result:** The settings menu collapses and the button becomes unchecked. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -810,7 +810,7 @@ Test 6: Settings button check. The **General** section contains **Harmonics type** (set to *harmonics* by default) and **Active channel** (set to *Ia* by default). - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -819,14 +819,14 @@ Test 6: Settings button check. 4. Select **Ib** from active channels dropdown. - **Expected result:** The Ib row from the table is highlighted (if the table is populated, then the plot data is changed accordingly). - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -836,7 +836,7 @@ Test 6: Settings button check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -864,7 +864,7 @@ Test 7: Data logging. - If data acquisition is running, the log section cannot be accessed. 3. Click on the **LOG** switch button. - **Expected result:** A browse section is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -873,7 +873,7 @@ Test 7: Data logging. 4. Click on the **Browse** button. - **Expected result:** An explorer window is displayed. Only directories can be selected. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -882,7 +882,7 @@ Test 7: Data logging. 5. Select a directory and click on the **Open** button. - **Expected result:** The explorer window is closed and the path to that directory is introduced in the browse section. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -891,7 +891,7 @@ Test 7: Data logging. 6. Click on the **Run** button. - **Expected result:** The **LOG** section remains open, but its elements can no longer be accessed and a .csv file is created in the selected directory. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -900,14 +900,14 @@ Test 7: Data logging. 7. Click on the **Stop** button. - **Expected result:** The **LOG** section can now be accessed, and the .csv file is populated with data. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -917,7 +917,7 @@ Test 7: Data logging. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -945,7 +945,7 @@ Test 8: Data logging wrong path. - If data acquisition is running, the log section cannot be accessed. 3. Click on the **LOG** switch button. - **Expected result:** A browse section is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -955,7 +955,7 @@ Test 8: Data logging wrong path. 5. Click on the **Run** button. - **Expected result:** The **LOG** section is closed and no .csv file is created. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -963,14 +963,14 @@ Test 8: Data logging wrong path. 6. Click on the **Stop** button. - **Expected result:** The **LOG** section remains closed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -980,7 +980,7 @@ Test 8: Data logging wrong path. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1006,7 +1006,7 @@ Test 9: PQEvents. 1. Click on the **Run** button. 2. Run ``iio_attr -u ip:127.0.0.1 -c pqm count0 countEvent 1`` command. - **Expected result:** The PQEvents indicator becomes active. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1014,7 +1014,7 @@ Test 9: PQEvents. 3. Click on the **Stop** button. - **Expected result:** The PQEvents indicator is still active. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1022,7 +1022,7 @@ Test 9: PQEvents. 4. Click on the **PQEvents** indicator. - **Expected result:** The PQEvents indicator becomes inactive. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1030,7 +1030,7 @@ Test 9: PQEvents. 5. Run ``iio_attr -u ip:127.0.0.1 -c pqm count0 countEvent 0`` command. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1040,7 +1040,7 @@ Test 9: PQEvents. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1064,11 +1064,11 @@ Waveform tool - Scopy version - Plugin version (N/A if not applicable) - Comments - * - - - - - - - - - + * - Andrei-Fabian Pop + - 17.02.2025 + - v2.0.0-beta-rc2-a3a7c43 + - N/A + - None Setup environment: ^^^^^^^^^^^^^^^^^^ @@ -1106,14 +1106,14 @@ is accessible without errors. an Info button, a Run button, a Single button, and a Settings button. The Settings menu is open, and the Settings button is in a checked state. In the center, there are two plots. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1123,7 +1123,7 @@ is accessible without errors. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1150,14 +1150,14 @@ Test 2: Info button check. 2. Click on the **Info** button. - **Expected result:** The Waveform documentation page is opened in the browser. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1167,7 +1167,7 @@ Test 2: Info button check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1194,7 +1194,7 @@ Test 3: Settings button check. 2. Click on the **Settings** button. - **Expected result:** The settings menu collapses and the button becomes unchecked. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1203,14 +1203,14 @@ Test 3: Settings button check. 3. Click on the **Settings** button. - **Expected result:** The settings menu opens, and the button is checked. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1220,7 +1220,7 @@ Test 3: Settings button check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1248,7 +1248,7 @@ Test 4: Settings timespan check. 3. Click on (+) button. - **Expected result:** The timespan is increased and the x-axis range is now [-newValue, 0]. The maximum value must be 10. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1257,14 +1257,14 @@ Test 4: Settings timespan check. 4. Click on (-) button. - **Expected result:** The timespan is decreased and the x-axis range is now [-newValue, 0]. The minimum value must be 0.02. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1274,7 +1274,7 @@ Test 4: Settings timespan check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1302,14 +1302,14 @@ Test 5: Settings rolling switch check. 3. Enable **Rolling mode** swich. - **Expected result:** The switch is turned on, and the "triggered by" dropdown is inactive. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1319,7 +1319,7 @@ Test 5: Settings rolling switch check. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1348,14 +1348,14 @@ Test 6: Single acquisition triggered. 3. Click on the **Single** button. - **Expected result:** The curves are displayed on the plot in single shot format. A single block of data is acquired. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1365,7 +1365,7 @@ Test 6: Single acquisition triggered. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1395,14 +1395,14 @@ Test 7: Single acquisition rolling. - **Expected result:** The curves are drawn from right to left until all the required samples for the plot are acquired. A single block of data is acquired. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1412,7 +1412,7 @@ Test 7: Single acquisition rolling. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1441,7 +1441,7 @@ Test 8: Data acquisition triggered. 3. Click on the **Start** button. - **Expected result:** The curves are displayed on the plot in single shot format. When new data is available, it is displayed on the screen. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1449,14 +1449,14 @@ Test 8: Data acquisition triggered. 4. Click on the **Stop** button. - **Expected result:** The data acquisition stops. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1466,7 +1466,7 @@ Test 8: Data acquisition triggered. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1498,7 +1498,7 @@ Test 9: Data acquisition rolling. - **Expected result:** The curves are drawn from right to left until all the required samples for the plot are acquired. If there are non-zero values, a continuous motion illusion is created. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1506,14 +1506,14 @@ Test 9: Data acquisition rolling. 4. Click on the **Stop** button. - **Expected result:** The data acquisition stops. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1523,7 +1523,7 @@ Test 9: Data acquisition rolling. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1551,24 +1551,24 @@ range of the other plot is modified and matches the zoom range. 2. Zoom in on the first plot to a range smaller than the x-axis range. - **Expected result:** The x-axis range of the second plot is modified and matches the range of the first plot. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. -**Comments:** +**Comments:** On Linux-arm64, on zoom out, the plot magnifier will not dissapear on plot 1 if zooming out from plot 2 (or vice versa) .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1596,7 +1596,7 @@ Test 11: Data logging. - If data acquisition is running, the log section cannot be accessed. 3. Click on the **LOG** switch button. - **Expected result:** A browse section is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1605,7 +1605,7 @@ Test 11: Data logging. 4. Click on the **Browse** button. - **Expected result:** An explorer window is displayed. Only directories can be selected. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1614,7 +1614,7 @@ Test 11: Data logging. 5. Select a directory and click on the **Open** button. - **Expected result:** The explorer window is closed and the path to that directory is introduced in the browser section. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1624,7 +1624,7 @@ Test 11: Data logging. - **Expected result:** The **LOG** section remains open, but its elements can no longer be accessed and a .csv file is created in the selected directory. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1633,14 +1633,14 @@ Test 11: Data logging. 7. Click on the **Stop** button. - **Expected result:** The **LOG** section can now be accessed, and the .csv file is populated with data. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1650,7 +1650,7 @@ Test 11: Data logging. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1678,7 +1678,7 @@ Test 12: Data logging wrong path. - If data acquisition is running, the log section cannot be accessed. 3. Click on the **LOG** switch button. - **Expected result:** A browse section is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1688,7 +1688,7 @@ Test 12: Data logging wrong path. 5. Click on the **Run** button. - **Expected result:** The **LOG** section is closed and no .csv file is created. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1696,14 +1696,14 @@ Test 12: Data logging wrong path. 6. Click on the **Stop** button. - **Expected result:** The **LOG** section remains closed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1713,7 +1713,7 @@ Test 12: Data logging wrong path. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1737,11 +1737,11 @@ Settings tool - Scopy version - Plugin version (N/A if not applicable) - Comments - * - - - - - - - - - + * - Andrei-Fabian Pop + - 17.02.2025 + - v2.0.0-beta-rc2-a3a7c43 + - N/A + - None Setup environment: ^^^^^^^^^^^^^^^^^^ @@ -1777,14 +1777,14 @@ is accessible without errors. 2. Observe the application's behavior. - **Expected result:** Three sections are displayed: **System Time**, **Logging**, and **Config Values**. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1794,7 +1794,7 @@ is accessible without errors. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1823,14 +1823,14 @@ correctly. and **Set** buttons. 3. Click on the **Read** button. - **Expected result:** All fields in the section are populated. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1840,7 +1840,7 @@ correctly. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1869,7 +1869,7 @@ correctly. and **Set** buttons. 3. Click on the **Read** button. - **Expected result:** All fields in the section are populated. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1879,13 +1879,13 @@ correctly. 5. Click on the **Write** button. 6. Click on the **Read** button. - **Expected result:** The **MsV Threshold** attribute value must be 0.40. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Windows 10, Linux-arm64 .. Details about the tested OS goes here. @@ -1895,7 +1895,7 @@ correctly. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). diff --git a/testing_results/testing_results_v2.0.0-beta-rc2/plugins/swiot1l/swiot1l_tests.rst b/testing_results/testing_results_v2.0.0-beta-rc2/plugins/swiot1l/swiot1l_tests.rst index 05883a2995..c97f96612b 100644 --- a/testing_results/testing_results_v2.0.0-beta-rc2/plugins/swiot1l/swiot1l_tests.rst +++ b/testing_results/testing_results_v2.0.0-beta-rc2/plugins/swiot1l/swiot1l_tests.rst @@ -24,11 +24,11 @@ If the test case has special requirements, they will be listed in the test case - Scopy version - Plugin version (N/A if not applicable) - Comments - * - - - - - - - - - + * - Andrei-Fabian Pop + - 12.02.2025 + - v2.0.0-beta-rc2-a3a7c43 + - N/A + - None Setup environment ------------------ @@ -111,23 +111,23 @@ with the selected device and that the plugin is able to correctly parse it. - **Expected Result**: - The plugin is able to connect to the device. - The Config instrument shows 4 disabled channels. - - **Actual result:** + - **Actual result:** The emulator is not found. If the emulator works, this test is a success. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. -**Comments:** +**Comments:** The iio-emu is not found for Linux-arm64. Issue #1904 opened. On Windows it works. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** FAIL .. The result of the test goes here (PASS/FAIL). @@ -156,7 +156,7 @@ to switch between Config and Runtime modes. automatically. - Upon reconnection, the Config instrument is replaced by 3 instruments: AD74413R, MAX14906, and Faults. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -169,7 +169,7 @@ to switch between Config and Runtime modes. automatically. - The AD74413R, MAX14906 and Faults instruments are replaced by the Config instrument. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -182,7 +182,7 @@ to switch between Config and Runtime modes. automatically. - Upon reconnection, the Config instrument is replaced by 3 instruments: AD74413R, MAX14906, and Faults. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -195,7 +195,7 @@ to switch between Config and Runtime modes. automatically. - The AD74413R, MAX14906 and Faults instruments are replaced by the Config instrument. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -209,7 +209,7 @@ to switch between Config and Runtime modes. - Upon reconnection, the Config instrument is replaced by 3 instruments: AD74413R, MAX14906, and Faults. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -222,13 +222,13 @@ to switch between Config and Runtime modes. - The AD74413R, MAX14906 and Faults instruments are replaced by the Config instrument. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -238,7 +238,7 @@ to switch between Config and Runtime modes. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -264,7 +264,7 @@ is able to configure the device correctly. - **Expected Result**: - Their respective dropdowns for device and function are accessible and not greyed out anymore. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -281,7 +281,7 @@ is able to configure the device correctly. automatically. - Upon reconnection, the Config instrument is replaced by 3 instruments: AD74413R, MAX14906, and Faults. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -293,7 +293,7 @@ is able to configure the device correctly. - **Expected Result**: - There are 6 channels available in the channel manager: 4 diagnostic channels, **voltage_out 1** and **voltage_in 2**. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -303,14 +303,14 @@ is able to configure the device correctly. - **Expected result:** There are 2 channels available in the channel manager **voltage 2** as INPUT and **voltage 3** as OUTPUT. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -320,7 +320,7 @@ is able to configure the device correctly. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -349,7 +349,7 @@ plot changes such as labels and timestamp are correctly modified. - The labels are displayed on the right side of the plot. - The X axis of the plot shows a 4s timespan, using the -4 to 0 range. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -359,7 +359,7 @@ plot changes such as labels and timestamp are correctly modified. - **Expected Result**: - The voltage_out 1 data is displayed on the plot from the right to the left side. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -370,23 +370,23 @@ plot changes such as labels and timestamp are correctly modified. - The measurements are displayed above the plot and the instant value for the first channel is around 0A. - - **Actual result:** + - **Actual result:** The measurements are not visible, instead they are jumbled in the top left corner. (on arm64) .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. -**Comments:** +**Comments:** Failed at step 4, arm64. Issue #1905 opened. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** FAIL .. The result of the test goes here (PASS/FAIL). @@ -420,7 +420,7 @@ displayed on the plot and measured by the instrument. - On the top right on the plot the status message displays: a number of samples at **1.2ksps**. - - **Actual result:** + - **Actual result:** The expected result. .. Actual test result goes here. @@ -429,7 +429,7 @@ displayed on the plot and measured by the instrument. 5. Set YMin to -1A and YMax to 10A. - **Expected result:** - The plot Y axis is scaled between -5A and 5A. - - **Actual result:** + - **Actual result:** Fail, the test is wrong, but the program is working as intended (by the law). .. Actual test result goes here. @@ -444,7 +444,7 @@ displayed on the plot and measured by the instrument. - The value is automatically changed to 8191. - Below the field the value 10.9V is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -453,7 +453,7 @@ displayed on the plot and measured by the instrument. 8. Run a Single capture and check the measurements: - **Expected result:** - The instant value of **voltage_in 2** shows 10V. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -462,7 +462,7 @@ displayed on the plot and measured by the instrument. 9. Run a Continuous capture and check the measurements: - **Expected result:** - The instant value of **voltage_in 2** shows 10V. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. @@ -475,7 +475,7 @@ displayed on the plot and measured by the instrument. dropping from the previous value to 5.5V. - The same value is displayed in the instant value measurement. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. @@ -489,24 +489,24 @@ displayed on the plot and measured by the instrument. dropping to 0V. - The same value is displayed in the instant value measurement. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. -**Comments:** +**Comments:** The test should be a success, but step 5 is wrong, so it fails. No issue was created, but the tests will be changed. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** FAIL .. The result of the test goes here (PASS/FAIL). @@ -541,7 +541,7 @@ displayed on the instrument. - **Expected result:** - The instant value of **diagnostic 5** shows around 10V, the same as **voltage_in 2**. - - **Actual result:** + - **Actual result:** The diag 5 is around 11, not 10, it fails, on ARM64 and Windows 10 .. Actual test result goes here. @@ -551,7 +551,7 @@ displayed on the instrument. - **Expected result:** - Both the **diagnostic 5** and **voltage_in 2** signals are dropping from the previous value to 5.5V. - - **Actual result:** + - **Actual result:** Correct. .. Actual test result goes here. @@ -561,24 +561,24 @@ displayed on the instrument. - **Expected result:** - Both the **diagnostic 5** and **voltage_in 2** signals are dropping from the previous value to around 2.7V. - - **Actual result:** + - **Actual result:** Correct .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. -**Comments:** +**Comments:** Test 6 fails. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** FAIL .. The result of the test goes here (PASS/FAIL). @@ -608,7 +608,7 @@ the number of enabled channels. - The status message on the top right of the plot displays a number of samples at **800 sps**. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -618,14 +618,14 @@ the number of enabled channels. - **Expected result:** - The status message on the top right of the plot displays a number of samples at **1.2 ksps**. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -635,7 +635,7 @@ the number of enabled channels. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -662,7 +662,7 @@ and the documentation is accessible. - **Expected result:** - A pop up with 2 options (Tutorial and Documentation) is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -671,7 +671,7 @@ and the documentation is accessible. 3. Click the **Documentation** button. - **Expected result:** - The AD74413R documentation is opened in a browser. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -683,7 +683,7 @@ and the documentation is accessible. - The AD74413R tutorial starts, guiding the user through the instrument's features and providing a button to Exit the tutorial. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -694,7 +694,7 @@ and the documentation is accessible. - The tutorial continues with the next step, always greying out the background and highlighting only the explained item. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -704,14 +704,14 @@ and the documentation is accessible. - **Expected result:** - The tutorial is closed and the user is returned to the instrument. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -721,7 +721,7 @@ and the documentation is accessible. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -747,7 +747,7 @@ time span can be correctly modified. - **Expected result:** - The X axis of the plots shows a 10s timespan, using the 0 to 10 range. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -757,14 +757,14 @@ time span can be correctly modified. - **Expected result:** - The X axis of the plots shows a 1s timespan, using the 0 to 1 range. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -774,7 +774,7 @@ time span can be correctly modified. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -803,7 +803,7 @@ displayed on the plot and measured by the instrument. - **Expected result:** - The plot trace rises from 0 to 1 for both channels. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -813,14 +813,14 @@ displayed on the plot and measured by the instrument. - **Expected result:** - The plot trace drops from 1 to 0 for both channels. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -830,7 +830,7 @@ displayed on the plot and measured by the instrument. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -857,7 +857,7 @@ and the documentation is accessible. - **Expected result:** - A pop up with 2 options (Tutorial and Documentation) is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -866,7 +866,7 @@ and the documentation is accessible. 3. Click the **Documentation** button. - **Expected result:** - The MAX14906 documentation is opened in a browser. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -878,7 +878,7 @@ and the documentation is accessible. - The MAX14906 tutorial starts, guiding the user through the instrument's features and providing a button to Exit the tutorial. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -889,7 +889,7 @@ and the documentation is accessible. - The tutorial continues with the next step, always greying out the background and highlighting only the explained item. - - **Actual result:** + - **Actual result:** Works, but the second tutorial step only displays a part of the text. .. Actual test result goes here. @@ -899,14 +899,14 @@ and the documentation is accessible. - **Expected result:** - The tutorial is closed and the user is returned to the instrument. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -916,7 +916,7 @@ and the documentation is accessible. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -943,7 +943,7 @@ can poll faults values for both devices. 2. Open the Faults instrument and run a **Single** capture. - **Expected result:** - Bit 10 is enabled on the AD74413R device. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. @@ -953,7 +953,7 @@ can poll faults values for both devices. - **Expected result:** - The section below the leds only displays the fault explanation for the selected bit. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. @@ -962,14 +962,14 @@ can poll faults values for both devices. 4. Turn **Faults explanation** off: - **Expected result:** - The section below the leds is hidden. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -979,7 +979,7 @@ can poll faults values for both devices. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1009,7 +1009,7 @@ can reset the polled values after a capture. - **Expected result:** - Bit 10 is not selected and the Faults explanation display all the text greyed out. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. @@ -1018,14 +1018,14 @@ can reset the polled values after a capture. 5. Run a **Reset stored** capture. - **Expected result:** - Both the leds for Bit 10 are turned off. - - **Actual result:** + - **Actual result:** Works as expected .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -1035,7 +1035,7 @@ can reset the polled values after a capture. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1061,7 +1061,7 @@ can poll faults values for both devices in continuous mode. 2. Open the Faults instrument and run a **Continuous** capture. - **Expected result:** - Bit 10 is enabled on the AD74413R device. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1071,7 +1071,7 @@ can poll faults values for both devices in continuous mode. - **Expected result:** - The **STORED** LED is turned off until the next polled value turns it on again. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1079,7 +1079,7 @@ can poll faults values for both devices in continuous mode. 4. Stop the Faults instrument. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -1089,7 +1089,7 @@ can poll faults values for both devices in continuous mode. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1116,7 +1116,7 @@ and the documentation is accessible. - **Expected result:** - A pop up with 2 options (Tutorial and Documentation) is displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1125,7 +1125,7 @@ and the documentation is accessible. 3. Click the **Documentation** button. - **Expected result:** - The Faults documentation is opened in a browser. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1137,7 +1137,7 @@ and the documentation is accessible. - The Faults tutorial starts, guiding the user through the instrument's features and providing a button to Exit the tutorial. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1148,7 +1148,7 @@ and the documentation is accessible. - The tutorial continues with the next step, always greying out the background and highlighting only the explained item. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1158,14 +1158,14 @@ and the documentation is accessible. - **Expected result:** - The tutorial is closed and the user is returned to the instrument. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -1175,7 +1175,7 @@ and the documentation is accessible. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL). @@ -1204,7 +1204,7 @@ power supply switch is turned off. - A status bar is displayed at the bottom of the instrument with a warning message that the system is not running at full capacity due to not being powered by the external supply. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. @@ -1213,14 +1213,14 @@ power supply switch is turned off. 3. Turn on the external power supply switch on the SWIOT device. - **Expected result:** - The status bar is not displayed. - - **Actual result:** + - **Actual result:** Works as expected. .. Actual test result goes here. .. -**Tested OS:** +**Tested OS:** Linux-arm64, Windows 10 .. Details about the tested OS goes here. @@ -1230,7 +1230,7 @@ power supply switch is turned off. .. Any comments about the test goes here. -**Result:** PASS/FAIL +**Result:** PASS .. The result of the test goes here (PASS/FAIL).