Wiring and termination
1 parent df03423 commit 1b7cc03

File tree

3 files changed

+15
-0
lines changed

3 files changed

+15
-0
lines changed
397 KB
Loading
305 KB
Loading

content/hardware/02.hero/shields/spe-shield/datasheet/datasheet.md

Lines changed: 15 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -84,6 +84,21 @@ Single Pair Ethernet (SPE) enables Ethernet communication over a single twisted
8484
<strong>Node Distance:</strong> Each node should maintain a maximum distance of <strong>5 cm</strong> from the bus to ensure stable communication and signal integrity.
8585
</div>
8686

87+
#### Connection Recomendations
88+
89+
When using the UNO SPE Shield screw terminals to wire the 10BASE‑T1S network you must meet the following recomendations:
90+
91+
- The cable used must be a twisted pair.
92+
- The maximum lenght of the multidrop mixing segment of the bus must be ≤ 25 m.
93+
- The multidrop mode can support up to 8 nodes on one mixing segment.
94+
- On a multidrop configuration, the stub distance must be ≤ 5 cm.
95+
96+
![Wiring configuration to meet the SPE standard](assets/wiring.png)
97+
98+
- Short the termination jumpers on the first and last nodes of the SPE bus.
99+
100+
![Termination usage on SPE networks with the UNO SPE Shield](assets/jumpers.png)