Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathtrv-script.py
More file actions
executable file
·96 lines (78 loc) · 3.5 KB
/
trv-script.py
File metadata and controls
executable file
·96 lines (78 loc) · 3.5 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
from ast import literal_eval
# Identifiers for TRV temperatures.
state.persist('pyscript.script_boosted_entities')
current_temperature_identifier = "current_temperature"
target_temperature_identifier = "temperature"
service_name_to_set_temperatures = "set_temperature"
# The temperature to set TRVs to to force them open.
# I've found that 21 degrees is a good balance between forcing them open
# and rooms getting too hot but this may need adjusting based on your
# preference.
temperature_used_to_open_trv = 20
attribute_trv_preset_mode = "preset_mode"
attribute_trv_when_manually_opened_value = "boost"
attribute_demand_check = "percentage_demand"
service_to_use_to_reset_trvs = "set_preset_mode"
service_to_use_to_reset_trvs_value = "Cancel Boost"
# pyscript.script_boosted_entities = []
@service
def trv_monitor():
# Get array of rooms with trvs.
trv_rooms = state.names("climate")
# We need to find out if a user (not this script) has manually increased the temperature.
isHeatingRequired = False
for room in trv_rooms:
# Get attributes for the room.
attributes = state.getattr(room)
current_temperature = attributes[current_temperature_identifier]
target_temperature = attributes[target_temperature_identifier]
if (
attributes[attribute_demand_check] > 0 and
(room not in literal_eval(pyscript.script_boosted_entities)) and
attributes['hvac_action'] != 'idle'
):
# Check if this has been set by the script or not.
isHeatingRequired = True
# There is a TRV which should be heating, we can now exit this loop
# and loop again and this time set TRVs which aren't supposed to be
# heating to a higher temperature to force them open.
break
if isHeatingRequired == True:
log.info("Heating is required.")
tmp_script_boosted_entities = literal_eval(pyscript.script_boosted_entities)
for room in literal_eval(pyscript.script_boosted_entities):
attributes = state.getattr(room)
if attributes['preset_mode'] != 'boost':
tmp_script_boosted_entities.remove(room)
pyscript.script_boosted_entities = tmp_script_boosted_entities
script_boosted_entities = []
for room in trv_rooms:
attributes = state.getattr(room)
current_temperature = attributes[current_temperature_identifier]
target_temperature = attributes[target_temperature_identifier]
# This time, if the current temperature is higher than the target
# temperature (when the TRV will be off), we can increase the target
# temperature to force the TRV open.
if (
attributes[attribute_demand_check] == 0 and
(room not in literal_eval(pyscript.script_boosted_entities))
):
service.call("climate", service_name_to_set_temperatures,
entity_id=room,
temperature=temperature_used_to_open_trv
)
script_boosted_entities.append(room)
log.info("Setting TRV for: " + room)
pyscript.script_boosted_entities = literal_eval(pyscript.script_boosted_entities) + script_boosted_entities
else:
log.info("Heating is not required.")
# Make sure to reset any TRVs that were previously set to a high
# back to their defaults.
for room in literal_eval(pyscript.script_boosted_entities):
attributes = state.getattr(room)
service.call("climate", service_to_use_to_reset_trvs,
entity_id=room,
preset_mode=service_to_use_to_reset_trvs_value
)
log.info("Resetting TRV for: " + room)
pyscript.script_boosted_entities = []