hwmon: (mr75203) fix voltage equation for negative source input
According to Moortec Embedded Voltage Monitor (MEVM) series 3 data
sheet, the minimum input signal is -100mv and maximum input signal
is +1000mv.
The equation used to convert the digital word to voltage uses mixed
types (*val signed and n unsigned), and on 64 bit machines also has
different size, since sizeof(u32) = 4 and sizeof(long) = 8.
So when measuring a negative input, n will be small enough, such that
PVT_N_CONST * n < PVT_R_CONST, and the result of
(PVT_N_CONST * n - PVT_R_CONST) will overflow to a very big positive
32 bit number. Then when storing the result in *val it will be the same
value just in 64 bit (instead of it representing a negative number which
will what happen when sizeof(long) = 4).
When -1023 <= (PVT_N_CONST * n - PVT_R_CONST) <= -1
dividing the number by 1024 should result of in 0, but because ">> 10"
is used, and the sign bit is used to fill the vacated bit positions, it
results in -1 (0xf...fffff) which is wrong.
This change fixes the sign problem and supports negative values by
casting n to long and replacing the shift right with div operation.
Fixes: 9d82335 ("hwmon: Add hardware monitoring driver for Moortec MR75203 PVT controller")
Signed-off-by: Eliav Farber <[email protected]>
Reviewed-by: Andy Shevchenko <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Guenter Roeck <[email protected]>1 parent bb9195b commit 227a3a2
1 file changed
+12
-2
lines changed| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
201 | 201 | | |
202 | 202 | | |
203 | 203 | | |
204 | | - | |
205 | | - | |
| 204 | + | |
| 205 | + | |
| 206 | + | |
| 207 | + | |
| 208 | + | |
| 209 | + | |
| 210 | + | |
| 211 | + | |
| 212 | + | |
| 213 | + | |
| 214 | + | |
| 215 | + | |
206 | 216 | | |
207 | 217 | | |
208 | 218 | | |
| |||
0 commit comments