Commit 927728a
serial: sc16is7xx: Clear RS485 bits in the shutdown
We tested RS485 function on an EVB which has SC16IS752, after
finishing the test, we started the RS232 function test, but found the
RTS is still working in the RS485 mode.
That is because both startup and shutdown call port_update() to set
the EFCR_REG, this will not clear the RS485 bits once the bits are set
in the reconf_rs485(). To fix it, clear the RS485 bits in shutdown.
Cc: <[email protected]>
Signed-off-by: Hui Wang <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Greg Kroah-Hartman <[email protected]>1 parent f25fbd5 commit 927728a