Notifications
You must be signed in to change notification settings - Fork 7
Description
Full name of submitter: Thomas Mejstrik (he gave me permission to file on his behalf)
Link to Mattermost thread: https://chat.isocpp.org/general/pl/uwia7opapif4imtrk63eym98ch
Issue description: All implementations agree that T
is deduced as int
in the following program:
#include <type_traits>
struct S {
template <typename T>
operator T() {
static_assert(std::is_same_v<int, T>);
}
};
const int& x = S();
However, [over.match.funcs.general]/7 specifies that operator const int&
is looked up in the scope of S
, and [temp.deduct.conv]/4 specifies that cv-qualifiers in const int&
are stripped before references, resulting in A = const int
which is then compared against P = T
.
By analogy to the case of deduction from a call, perhaps the above deduction should simply fail because the T
in operator T
should never be deduced to a reference type unless its address is taken.
Suggested resolution (by Brian):
Edit [over.match.funcs.general]/7:
In each case where conversion functions of a class
S
are considered for initializing an objector referenceof type T, the candidate functions include the result of a search for the conversion-function-idoperator T
inS
([over.match.copy], [over.match.conv]).
Insert two bullets before [over.match.ref]/1.1:
[...] Assuming that “reference to cv1 T” is the type of the reference being initialized, the candidate functions are selected as follows:
- When converting to an lvalue, the candidates include the result of a search for the conversion-function-id
operator cv1 T&
inS
([class.member.lookup], [temp.deduct.conv]).- When converting to an rvalue or function lvalue, the candidates include the results of searches for the conversion-function-ids
operator cv1 T
andoperator cv1 T&&
inS
.- Let R be a set of types including [...] The permissible types are [...]
Insert a paragraph after [temp.deduct.conv]/1:
Template argument deduction is done by comparing the return type of the conversion function template (call it P) with the type specified by the conversion-type-id of the conversion-function-id being looked up (call it A) as described in [temp.deduct.type].
If the conversion-function-id is constructed during overload resolution ([over.match.funcs]), the rules in the remainder of this subclause apply.If
A
is a reference type andP
is not, deduction fails.